i safe MOBILE MSW1A01 Android 4G Smartphone User Manual

June 8, 2024
i safe MOBILE

i safe MOBILE MSW1A01 Android 4G Smartphone

READ AND UNDERSTAND THE INSTRUCTIONS

PROTECT YOUR LIFE AND READ THE OPERATING MANUAL
This Operating Manual is part of the device IS-SW1.1 (model MSW1A01). This Operating Manual provides important information for safe use of the device.

  • Before using the device, read this Operating Manual carefully and pay particular attention to the “Safety” section and the warnings highlighted with the warning symbol.
  • Also read the Safety Instructions before using the device.
  • You can find these at www.isafe-mobile.com/en/support/downloads
  • Make sure you have access to this Operating Manual when you need it. You can find the current Operating Manual at www.isafe-mobile.com/en/support/downloads
  • Follow all instructions given on the device and on the packaging.
  • Follow local safety regulations.

INTENDED USE

The IS-SW1.1 is a Smartwatch for use in explosion hazardous areas of Zone 1/21 and 2/22, in accordance with Directives 2014/34/EU, SI 2016 No. 1107, 1999/92/EC and the IECEx system, among others. Only use the device as described in this Operating Manual. Any other use is considered improper and can lead to death, severe injuries and damage to the device. The manufacturer i.safe MOBILE GmbH does not assume any liability for damage caused by improper use. The warranty expires in the event of improper use.

DEVICE OVERVIEW/FUNCTIONS

i safe-MOBILE-MSW1A01-Android-4G-Smartphone-
FIG1

  1. TOUCHSCREEN

  2. POWER KEY: A long press switches the device on/off. Depending on where you are in
    the menu, a short press can have the following function:

    • Switch off standby mode
    • Go to menu
    • Go to watch face
  3. SIDE KEY RIGHT: Depending on where you are in the menu, a short press can have
    the following function:

    • Switch on/off standby mode
    • Go to previous screen
  4. SOS KEY/SIDE KEY LEFT: A long press of the SOS key sends an emergency call to a pre-saved emergency number (only in connection with a smartphone and an installed Lone Worker Protection app)./Optional function – function can be assigned via Companion App (system integrated in connection with a smartphone).

  5. SENSORS

  6. CHARGING CONTACTS

  7. WRISTBAND

  8. IS-DCSW1.1 DESKTOP CHARGER

  9. USB INTERFACE: Connection for the i.safe PROTECTOR 2.0 USB-C Cable. Also see sections “Charging” and “Data transfer”.

  10. CHARGING CONTACTS

SAFETY

Read the “Safety” section of this Operating Manual carefully before using the device. If you do not follow these instructions or do not understand them, this could lead to death, severe injuries and damage to the device.

USER
Only trained users who are qualified in the use of Ex devices in explosion hazardous areas and who have read and understood this Operating Manual may use this device.
USE IN EXPLOSION-HAZARDOUS AREAS
DANGER
Improper use can result in death or severe injuries!

  • Only use the device in explosion-hazardous areas of zones 1/21 and 2/22 or outside of explosion-hazardous areas.
  • Before entering an explosion hazardous area with the device,
    • make sure that no gap can be seen between the two halves of the device,
    • make sure the device is not damaged,
    • make sure that all the labels on the device are readable.
  • If you use the device in an explosion-hazardous area, read and follow the instructions in the “Possible User Errors” section.
  • Switch off the device immediately and leave the explosion hazardous area without delay if
    • malfunctions occur on the device,
    • you have damaged the housing of the device,
    • you have exposed the device to excessive loads,
    • the labels on the device are no longer readable.

USE OUTSIDE OF EXPLOSION HAZARDOUS AREAS
DANGER
Improper use can result in death or severe injuries!

  • Do not use the device in places where its use is prohibited.
  • ake sure you prevent the user errors described in the section entitled “Possible User Errors”.
  • Only charge the device as described in the “Charging” section.

NOTICE
Incorrect use can damage the device.

  • Protect the device, the IS-DCSW1.1 Desktop Charger and the Power Adapter from strong electrical magnetic fields as for example those emitted by induction cookers or microwave ovens, for example.
  • Do not touch the touchscreen with sharp objects.

POSSIBLE USER ERRORS

DANGER
Improper use can result in death or severe injuries! Follow the instructions below:

  • Do not open the device.
  • Do not damage the device.
  • Do not loosen the screws on the back of the device.
  • Do not modify the device structurally.
  • Do not expose the device to high temperatures.
  • Do not expose the device to strong UV radiation.
  • Do not expose the device to processes with high electrical charges.
  • Do not expose the device to aggressive acids or bases.

When working in explosion-hazardous areas, please note:

  • Do not change the wristband.
  • Do not charge the device.

SCOPE OF DELIVERY
Your device packaging contains the following:

  • 1 x IS-SW1.1
  • 1 x Quick Start Manual
  • 1 x Safety Instructions
  • 1 x IS-DCSW1.1 Desktop Charger
  • 1 x i.safe PROTECTOR 2.0 USB-C Cable
  • 1 x Power Adapter universal (power supply unit and various country-specific adapters)
  • 1 x Screwdriver

CHARGING
DANGER
An incorrect procedure in explosion-hazardous areas poses risk of death or severe injuries! Only charge the device outside of explosion-hazardous areas. Do not charge the device in the vicinity of flammable substances.

NOTICE
Incorrect charging can cause damage to the device. Please note the following when charging:

  • Only charge the device using the IS-DCSW1.1 Desktop Charger and the i.safe PROTECTOR 2.0 USB-C Cable supplied. Only charge the device at ambient temperatures between 0 °C to +45 °C (+32 °F to +113 °F).
  • Charge the device under dry indoor conditions only.
  • Do not charge the device in environments dusty or humid.

Your device package contains the IS-DCSW1.1 Desktop Charger, a power supply unit, various country-specific adapters and an i.safe PROTECTOR 2.0 USB-C Cable.

  • Connect the adapter suitable for your country to the power supply unit.
  • Connect the i.safe PROTECTOR 2.0 USB-C Cable to the power supply unit.
  • Connect the i.safe PROTECTOR 2.0 USB-C Cable to the USB interface of the IS-DCSW1.1 Desktop Charger.
  • Insert the IS-SW1.1 Smartwatch into the IS-DCSW1.1 Desktop Charger.
  • Plug the Power Adapter into a power socket and charge the device completely

WEARING THE DEVICE

  • Wear the device above your wrist bone.
  • Fit the device snugly but comfortably on your wrist. The device is properly seated if it does not move while walking.

SWITCHING ON/OFF

  • Press and hold the power key for about 3 seconds.

USING THE DEVICE

  • When turning on the device for the first time, follow the instructions on the touchscreen.

TOUCHSCREEN

  • Swipe up or down to scroll through widgets, features and menus.
  • Tap to select.
  • Swipe right to go to the previous screen.
  • Hold to view a menu of settings and options for the current screen.

Further information on operating the device can be found at www.isafe- mobile.com/en/support/service under the menu item “FAQ”.

DATA TRANSFER
The USB interface on the IS-DCSW1.1 Desktop Charger is used for charging and data transfer.

DANGER
Improper use can result in death or severe injuries! Only use USB interface outside of explosion hazardous areas.

  • Insert the IS-SW1.1 Smartwatch into the IS-DCSW1.1 Desktop Charger.
  • Connect other devices to the USB interface of the IS-DCSW1.1 Desktop Charger only by using the i.safe PROTECTOR 2.0 USB-C Cable.

CHANGING THE WRISTBAND

DANGER
Improper use can result in death or severe injuries! Only change the wristband outside of explosion hazardous areas.i safe-MOBILE-MSW1A01-Android-4G-
Smartphone-FIG3

  • Loosen only the screws (1) on the right side of the IS-SW1.1 Smartwatch with the screwdriver provided.
  • Slide out the threaded sleeves connecting the wristband to the IS-SW1.1 Smartwatch from right to left with the screwdriver.
  • Remove the wristband and insert the new wristband.
  • Insert the threaded sleeves from the left.
  • Insert the screws on the right and tighten them hand-tight with the screwdriver provided.

POSSIBLE DEVICE PROBLEMS
You can find information on possible device problems and how to rectify them at
www.isafe-mobile.com/en/support/service under the menu item “FAQ”.
If you have any further questions, please contact the i.safe MOBILE repair service at
www.isafe-mobile.com/en/support/service

MAINTENANCE/REPAIR

The device itself has no serviceable parts.

WARNING
Incorrect repairs present a risk of explosion or fire, which can result in death or severe injuries! Do not open the device or carry out any repairs yourself.

  • Contact the i.safe MOBILE repair service at www.isafe-mobile.com/en/support/service if the device is not working normally, if the device needs to be repaired or if a replacement part is required.

RETURN SHIPMENT
Contact the i.safe MOBILE repair service at www.isafe- mobile.com/en/support/service

DISTRIBUTION PARTNER
You can find the specialist distribution partner responsible for your country at www.isafe-mobile.com/en/contact

CLEANING

NOTICE
Incorrect cleaning can cause damage to the device. Please note the following when cleaning:

  • Turn off the device before cleaning.
  • Do not charge the device while cleaning.
  • Do not use chemical agents for cleaning.
  • Clean the IS-SW1.1 Smartwatch, the IS-DCSW1.1 Desktop Charger and the Power Adapter with a soft, moistened antistatic cloth.
  • Clean the touchscreen regularly with a soft, antistatic cloth.

STORAGE

NOTICE
Incorrect storage can cause damage to the device. Store the device at a humidity of 10 % to 60 % at the following ambient temperatures:

  • Up to one month: -20 °C to +45 °C (-4 °F to +113 °F)
  • Up to 3 months: -10 °C to +35 °C (+14 °F to +95 °F)
  • Over 3 months: -10 °C to +25 °C (+14 °F to +77 °F)

RECYCLING
NOTICE
Incorrect disposal of electronic products, batteries and packaging material puts the
environment at risk. Please note the following when disposing of items:

  • DO NOT throw away batteries with household waste.
  • Always dispose of electronic products, batteries and packaging material at the appropriate collection points. This way, you prevent uncontrolled waste disposal and promote the recycling of material resources.

WARRANTY

You can find the warranty conditions at www.isafe- mobile.com/en/support/service For any damage caused by computer viruses that you download while using the Internet functions responsibility is at your hand. There is no right of recourse against i.safe MOBILE GmbH.

EU/UK DECLARATION OF CONFORMITY
You will find the EU/UK declaration of conformity at
www.isafe-mobile.com/en/support/downloads
FCC/IC STATEMENT
The FCC/IC declaration can be found at
www.isafe-mobile.com/en/support/downloads

EX MARKINGS

ATEX:

  • II 2G Ex ib IIC T4 Gb
  • II 2D Ex ib IIIC T135 °C Db

EU Type Examination Certificate:

  • EPS 22 ATEX 1 196 X
  • CE-designation: 2004

IECEx:

  • Ex ib IIC T4 Gb
  • Ex ib IIIC T135 °C Db
  • IECEx Certificate: IECEx EPS 22.0028X

UKEX:

  • II 2G Ex ib IIC T4 Gb
  • II 2D Ex ib IIIC T135 °C Db
  • EPS 22 UKEX 1 196 X
  • UKCA-designation: 2503

Temperature range:

  • -10 °C … +55 °C (EN/IEC 60079-0)
  • -10 °C … +55 °C (EN/IEC 62368-1)

Manufactured by:
i.safe MOBILE GmbH
i_Park Tauberfranken 10
97922 Lauda-Koenigshofen
Germany

You can obtain further information from regional waste disposal companies, state authorities or the i.safe MOBILE service centre responsible for your country or region at www.isafe-mobile.com/en/support/service

TRADEMARKS
i.safe MOBILE and the i.safe MOBILE logo are registered trademarks of the i.safe MOBILE GmbH. All other trademarks and copyrights are the properties of their respective owners.

CONTACT/SERVICE CENTRE

FOR FURTHER QUESTIONS PLEASE CONTACT OUR SERVICE CENTRE:
i.safe MOBILE GmbH, i_Park Tauberfranken 10, 97922 Lauda-Koenigshofen, Germany
[email protected]
https://support.isafe-mobile.com

www.isAFE-MOBILE.COM

Document No. 1062MM10REV00
Version: 2022-11-14
(c) 2022 i.safe MOBILE GmbH
i.safe MOBILE GmbH
i_Park Tauberfranken 10
97922 Lauda-Koenigshofen
Germany
Tel. +49 9343 60148-0
[email protected]
www.isafe-mobile.com

This Operating Manual complies with these standards:
IEC 60079, IEC 82079, ANSI Z535.6 Diese Bedienungsanleitung erfüllt die Anforderungen der folgenden Normen: IEC 60079, IEC 82079, ANSI Z535.6

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

i safe MOBILE User Manuals

Related Manuals