Ring Motion Detector v2 EU Motion Detector v2 EU Manual
- June 8, 2024
- Ring
Table of Contents
- Ring
- Motion Detector v2 EU
- SKU: Motion Detector v2 EU
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Heartbeat Interval
- Parameter 10: Lighting Delay
- Parameter 11: Supervisory Report Timeout
- Parameter 2: Application Retriess
- Parameter 3: Application Level Retry Base Wait Time Period
- Parameter 4: LED Indicator Enable
- Parameter 5: Runtime Occ Clear Delay
- Parameter 6: Runtime Intrusion Clear Delay
- Parameter 7: Runtime Std Clear Delay
- Parameter 8: Motion Detection Mode
- Parameter 9: Lighting Enabled
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Ring
Motion Detector v2 EU
SKU: Motion Detector v2 EU
Quickstart
This is a
secure
Alarm Sensor
for
.
Please make sure the internal battery is fully charged.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Ring Alarm Motion Detector is a wireless sensor for the Ring Alarm system which provides users the ability to know when there is movement of a person or similar object within an area. After installing the sensor and setting up the sensor in the Ring app, monitor and receive notifications motion is detected. The Ring Alarm Base Station is required to enable Motion Detector features and functions within the Ring app.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 5| This is the Lifeline group with the following command class support
-1.Notification Reporta.See notification CC section for notifications that are
sent2.Battery Report3.Device Reset Locally Notification
---|---|---
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Heartbeat Interval
This parameter is the number minutes between heartbeats. Heartbeats are
automatic battery reports on a timer after the last event.
Size: 1 Byte, Default Value: 70
SettingDescription
1 – 70 | This parameter indicates the time between heartbeats in minutes. |
---|
Parameter 10: Lighting Delay
Delay used to turn off lights when motionis no longer detected
Size: 1 Byte, Default Value: 2
SettingDescription
0 – 60| This parameter indicates the Delay used to turn off lights when
motionis no longer detected.
---|---
Parameter 11: Supervisory Report Timeout
The number of milliseconds waiting for a Supervisory Report response to a
Supervisory Get encapsulated command from the sensor before attempting a
retry.
Size: 2 Byte, Default Value: 10000
SettingDescription
500 – 30000| This parameter indicates the number of milliseconds waiting for a
Supervisory Report.
---|---
Parameter 2: Application Retriess
Number of application level retries attempted for messages either not ACKed
or messages encapsulated via supervision get that did not receive a report.
Size: 1 Byte, Default Value: 1
SettingDescription
0 – 5 | This parameter indicates the Number of application level retries. |
---|
Parameter 3: Application Level Retry Base Wait Time Period
The number base seconds used in the calculation for sleeping between retry
messages.
Size: 1 Byte, Default Value: 5
SettingDescription
1 – 96| This parameter indicates the number base seconds used in the
calculation for sleeping between retry messages.
---|---
Parameter 4: LED Indicator Enable
This parameter allows a user, via software, to configure the various LED
indications on the device.0 == Don’t show green1 == Show green after
Supervision Report Intrusion (Fault)2 == Show green after Supervision Report
both Intrusion and Intrusion clear
Size: 1 Byte, Default Value: 1
SettingDescription
0 – 2| This parameter allows a user to configure LED indications on the
device.
---|---
Parameter 5: Runtime Occ Clear Delay
Delay time in secondsfor occupancy signal to clear
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 255 | Delay time in secondsfor occupancy signal to clear |
---|
Parameter 6: Runtime Intrusion Clear Delay
Delay time in secondsfor intrusion signal to clear
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 255 | Delay time in secondsfor intrusion signal to clear |
---|
Parameter 7: Runtime Std Clear Delay
Standard delay time in seconds
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 255 | This parameter is theStandard delay time in seconds |
---|
Parameter 8: Motion Detection Mode
Adjusts motion sensitivity
Size: 1 Byte, Default Value: 3
SettingDescription
0 – 4 | This parameter adjusts motion sensitivity |
---|
Parameter 9: Lighting Enabled
Enable or Disable light sensor
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 1 | This parameter is used to Enable or Disable light sensor |
---|
Technical Data
Hardware Platform | EFR32Z |
---|---|
Device Type | Notification Sensor |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 1 FW: 1.08:01.04 |
Z-Wave Version | 7.12.4 |
Certification ID | ZC12-21040218 |
Z-Wave Product Id | 0x0346.0x0301.0x0301 |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info V3
- Association V2
- Battery
- Configuration V4
- Device Reset Locally
- Firmware Update Md V5
- Indicator V3
- Manufacturer Specific V2
- Multi Channel Association V3
- Notification V8
- Powerlevel
- Security 2
- Supervision
- Transport Service V2
- Version V3
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>