Ring Motion Detector v2 EU Motion Detector v2 EU Manual

June 8, 2024
Ring

Ring

Motion Detector v2 EU

SKU: Motion Detector v2 EU

Quickstart

This is a
secure
Alarm Sensor
for
.

Please make sure the internal battery is fully charged.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

Ring Alarm Motion Detector is a wireless sensor for the Ring Alarm system which provides users the ability to know when there is movement of a person or similar object within an area. After installing the sensor and setting up the sensor in the Ring app, monitor and receive notifications motion is detected. The Ring Alarm Base Station is required to enable Motion Detector features and functions within the Ring app.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1| 5| This is the Lifeline group with the following command class support -1.Notification Reporta.See notification CC section for notifications that are sent2.Battery Report3.Device Reset Locally Notification
---|---|---

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Heartbeat Interval

This parameter is the number minutes between heartbeats. Heartbeats are automatic battery reports on a timer after the last event.
Size: 1 Byte, Default Value: 70

SettingDescription

1 – 70 This parameter indicates the time between heartbeats in minutes.

Parameter 10: Lighting Delay

Delay used to turn off lights when motionis no longer detected
Size: 1 Byte, Default Value: 2

SettingDescription

0 – 60| This parameter indicates the Delay used to turn off lights when motionis no longer detected.
---|---

Parameter 11: Supervisory Report Timeout

The number of milliseconds waiting for a Supervisory Report response to a Supervisory Get encapsulated command from the sensor before attempting a retry.
Size: 2 Byte, Default Value: 10000

SettingDescription

500 – 30000| This parameter indicates the number of milliseconds waiting for a Supervisory Report.
---|---

Parameter 2: Application Retriess

Number of application level retries attempted for messages either not ACKed or messages encapsulated via supervision get that did not receive a report.
Size: 1 Byte, Default Value: 1

SettingDescription

0 – 5 This parameter indicates the Number of application level retries.

Parameter 3: Application Level Retry Base Wait Time Period

The number base seconds used in the calculation for sleeping between retry messages.
Size: 1 Byte, Default Value: 5

SettingDescription

1 – 96| This parameter indicates the number base seconds used in the calculation for sleeping between retry messages.
---|---

Parameter 4: LED Indicator Enable

This parameter allows a user, via software, to configure the various LED indications on the device.0 == Don’t show green1 == Show green after Supervision Report Intrusion (Fault)2 == Show green after Supervision Report both Intrusion and Intrusion clear
Size: 1 Byte, Default Value: 1

SettingDescription

0 – 2| This parameter allows a user to configure LED indications on the device.
---|---

Parameter 5: Runtime Occ Clear Delay

Delay time in secondsfor occupancy signal to clear
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 255 Delay time in secondsfor occupancy signal to clear

Parameter 6: Runtime Intrusion Clear Delay

Delay time in secondsfor intrusion signal to clear
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 255 Delay time in secondsfor intrusion signal to clear

Parameter 7: Runtime Std Clear Delay

Standard delay time in seconds
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 255 This parameter is theStandard delay time in seconds

Parameter 8: Motion Detection Mode

Adjusts motion sensitivity
Size: 1 Byte, Default Value: 3

SettingDescription

0 – 4 This parameter adjusts motion sensitivity

Parameter 9: Lighting Enabled

Enable or Disable light sensor
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 1 This parameter is used to Enable or Disable light sensor

Technical Data

Hardware Platform EFR32Z
Device Type Notification Sensor
Network Operation Listening Sleeping Slave
Firmware Version HW: 1 FW: 1.08:01.04
Z-Wave Version 7.12.4
Certification ID ZC12-21040218
Z-Wave Product Id 0x0346.0x0301.0x0301
Security V2 S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info V3
  • Association V2
  • Battery
  • Configuration V4
  • Device Reset Locally
  • Firmware Update Md V5
  • Indicator V3
  • Manufacturer Specific V2
  • Multi Channel Association V3
  • Notification V8
  • Powerlevel
  • Security 2
  • Supervision
  • Transport Service V2
  • Version V3
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals