PLNetworks PLG400 LoRaWAN Gateway Instruction Manual

June 6, 2024
pLNetworks

PLNetworks PLG400 LoRaWAN Gateway Instruction Manual
PLNetworks PLG400 LoRaWAN Gateway

Revision History

Who| Version| Date|

Comment

---|---|---|---

Benjamin Lee

| 1.0| Jul 17, 2019|

Initial release

Aaron Hwang

| 1.1|

Feb 03, 2020

Introduction

IT refers to the connection of wireless and wired-based sensing systems to the Internet and the web. Through this, the value of sensing data is maximized by facilitating the use of sensing data

LoRa Gateway is located between the Node and the Network Server system and converts the sensing data provided by the Node into a Network Server compatible format and transmits the commands sent from the Network Server to the Node. Usually, a Linux router with wired (Ethernet) and wireless (Bluetooth, LoRa, ZigBee, etc.) communication interfaces based on processors such as ARM Cortex-A series and MIPS.

PLG400 is a LoRaWAN gateway that can be installed outdoors. LoRaWAN is a low power wide area (LPWA) wireless network technology widely used in the Internet of Things, and the PLG400 connects various installed LoRa sensors to the Internet.

Hardware Specification

Category|

Description

---|---

H/W

|

CPU

| 800MHz Sitara™ ARM® Cortex®-A8 32-Bit RISC Processor (AM3352ZCZA80)

SDRAM

| 512MB DDR3L SDRAM

Flash

| 4GB NAND Flash with MMC controller

Power Supply

| DC 48V PoE, 24W

Dimension

| 226 x 183 x 65 (W x H x D, mm)

Weight

| 1.7Kg

RF

|

LoRa

| SX1301

I/O

|

Ethernet

| 10/100/1000 B-TX 1 Port With POE

Console

| Micro USB

USB

| 2.0 Full-Speed x2 (USB A Type)

S/W

|

OS

| Linux kernel 4.14.79 (32bit)

The hardware specifications of the PLG400 are as follows

Description of each part of PLG400 is as follows.

  • Front
    Front
  1. LoRa: LoRa Antenna connection Port.
  2. GPS: GPS Antenna connection Port.
  • Rear
    Rear
  1. PoE 48V: Power & WAN connection Port
  2. Pressure valve

Components

Category|

Quantity

---|---

PLG400 Gateway

| 1
LoRa Antenna|

1

GPS Antenna

| 1
PoE Injector|

1

Quick Start

The PLG400 is set up to connect to the WAN using DHCP. Therefore, a PoE injector can be used to connect a LAN for the Internet connection to the WAN and connect the power. When the power is connected, the PWR, WAN inside the device turn on.

Preferences

Connection & Login

To change various settings of the PLG400, you need to access the built-in web interface.

  • Access the assigned IP through the WAN port of the gateway. If you are using a static IP or know the IP address assigned through a DHCP server, you can use that IP address to connect.
  • Enter port 8080 after the IP address to connect. Ex) http: // [IP address]: 8080

When connected, the login screen will appear as shown below.
Connection & Login

ID and Password to input are as follows.

ID|

root

---|---
Password|

admin

After logging in, the PLG400 system screen appears.
Connection & Login

Shows the model and network, firmware and kernel versions currently reflected in the PLG400.

Networks

Networks

The displayed parameters represent the values currently set in the PLG400. Set the IP address that the PLG400 will use to connect to the WAN.

  • Static / DHCP: Set whether to use static or dynamic IP.
  • Local IP: If you are using a static IP, enter the IP address to use.
  • Net mask: Enter the sub net mask if using static IP.
  • Gateway: If using a static IP, enter the gateway IP address to use

Click on the ‘Save’ button at the bottom to save the settings.

LoRaWAN

LoRaWAN

LoRaWAN parameter value can be set.

  • You can adjust Keep Alive interval of IP, Port and Gateway of Network Server.
  • Io Town GID can get the basic information (Boot Time, Recent Act., Etc.) of the Gateway by using the same name when registering the Gateway in the Network Server..
OpenVPN

OpenVPN

You can configure the settings for using Open VPN (Protocol, VPN Server IP, etc.).

Log

Log

t shows the status window and log related to the linkage between PLG400 and LRR (server).
If you press ‘Shell’ button, you can search the status by typing Shell command at the bottom.
Four Commands can be entered.

  • ps
  • cat
  • ls –al
  • systemctl stop [process name]
Software Update

Software Update

You can update configuration files, applications, and kernel files.
To update the file, press File Select to select the file, click Upload to upload the file, and then click the ‘Apply’ button. Reboot proceeds after applying and takes 2 ~ 30 seconds.

Gateway installation environment and examples

  • Gateway installation environment
    • Erect and install a separate pole on the roof of a building or on a high terrain to accommodate multiple node sensors.
    • Install directly using a bracket on the pole or install it in a separate dedicated enclosure.
  • Gateway installation examples

Gateway installation environment and examples
Gateway installation environment and examples

Troubleshooting

  • The PWR LED does not light up.
    • Make sure the 48V PoE adapter provided with the gateway is physically connected
    • After removing the adapter, apply power again after a full discharge (approximately 20 to 30 seconds).
  • LoRa LED does not light up.
    • Check that the gateway is registered in the network server as a compatible device.
    • After pressing the reset switch, check if it operates normally.
  • The WAN LED does not light up.
    • LAN Check if the LAN cable is properly connected to the WAN port.
    • Check that the gateway is registered in the network server as a compatible device.

FCC Statement

Caution
Any changes or modifications (including the antenna) made to this device that are not expressly approved by the manufacturer may void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference. and
  2. This device must accept any interference received, including interference that may cause undesired operation.

To comply with FCC RF exposure compliance requirements, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons. This device must not be co-located or operation in conjunction with any other antenna or transmitter.

This equipment complies with FCC

Copyright © 2018 PLNetworks
The information contained herein is the property of PLNetworks and is provided without liability of errors, omissions, and mistakes. No part may be reproduced or copied without written permission or contract.

Documents / Resources

| PLNetworks PLG400 LoRaWAN Gateway [pdf] Instruction Manual
PLG400, 2AUV6-PLG400, 2AUV6PLG400, PLG400 LoRaWAN Gateway, PLG400, LoRaWAN Gateway
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals