Popp 10 Year Smoke Detector POPE700342 Manual
- June 8, 2024
- POPP
Table of Contents
- Popp
- 10 Year Smoke Detector
- SKU: POPE700342
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Installation
- Inclusion/Exclusion
- Product Usage
- Node Information Frame
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Firmware-Update over the Air
- Association – one device controls an other device
- Configuration Parameters
- Technical Data
- Supported Command Classes
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Popp
10 Year Smoke Detector
SKU: POPE700342
Quickstart
This is a
secure
Alarm Sensor
for
Europe.
To run this device please insert fresh *1 ER14250 1/2AA** batteries.
Please make sure the internal battery is fully charged.
Please insert the Z-Wave module including the battery into the smoke detector main device” first. Pressing the “Z-Wave button” includes and excludes the device. Keeping the button pushed for 3 seconds will force secure inclusion.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
This smoke detector will report smoke alarms wirelessly and securily into a Z-Wave network and is able to control other devices using associations The smoke detector?s sensor head is certified with the Q quality label, conforms DIN EN 14604 and satisfies all contemporary legal requirements. The High-End 10-years smoke detector offers a large test button conveniently accessible even with a broomstick when mounted on the sealing. The smoke chamber is monitored electronically to avoid any malfunction and wrong alerts. The device will also report its end of life to make sure it is getting replaced on time. Tampering a smoke detector by removing it from the mounting base will issue a wireless alarm command as well.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
To reset the device keep the button pushed for 10 seconds. After 5 seconds the led starts flashing and after another 5 seconds there is a short beep signaling the successful reset back to factory defaults.
Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is
not used.
Do not mix batteries of different charging level or different brands.
Installation
Please refer to the installation guide of the smoke sensor for information about how and where the smoke sensor should be installed. The installation guide complies with the norm DIN EN 14676.
- The first step is to mount the mounting base on the desired place in the home using screws.
- Remove the battery isolation strip from the wireless module. The yellow LED will start blinking.
- Include the Smoke Sensor into your existing Z-Wave based Smart Home Network using the Z-Wave button.
- Place the Smoke Detector on the mounting base and turn clockwise. Now the Smoke Detector is armed.
- Battery Change: The battery of the wireless module will be empty much earlier than the 10 years soldered in battery of the smoke sensor. To replace the battery, remove the Smoke Detector, pull off the wireless module from the smoke sensor. Then you can replace the 1/2 AA battery and replug the wireless module.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Secure Inclusion: Push the button for 3 seconds
Unsecure Inclusion: Push the button for 1 seconds
Exclusion
Push the button for 1 second
Product Usage
In case smoke is detected by the smoke detector the device will sound and the wireless module will issue a Z-Wave alarm command to the main controller and BASIC commands other associated devices. The value of the BASIC message is defined in Configuration Parameters 3 and 4. The device will report the battery level of the module but not the level of the built-in battery of the detector head. ” Once the device is placed on the mounting plate the tamper protection is active. Whenever the smoke detector head will be removed from the base for more than 4 seconds a tamper alarm will be sent wirelessly to the main controller. Note: All communication of the wireless module is performed with application-level security if the device was included securely and all communication partners support secure communication as well. In case a non- secure device is associated with switching on smoke alarms (in association group 2), the smoke detector will detect this and change the communication style to non-secure for this very device only. This process happens one time and will take about 20 seconds. This delay will happen on first communication only.
Alarm Messages
The device will issue the following (unsolicited) alarm messages:
- Smoke Detected (this alarm message will be issued as well when the test button is pressed)
- Low Battery Alarm (when the battery of the wireless modules goes low), indicated by yellow LED
- Tamper Detected (ON, when the smoke detector head is removed from the base; OFF, when the detector head is mounted to the base)
- End of Life (issued, when the Detector Main Head has reached its end of life after 10+ years.)
Node Information Frame
The Node Information Frame (NIF) is the business card of a Z-Wave device. It
contains
information about the device type and the technical capabilities. The
inclusion and
exclusion of the device is confirmed by sending out a Node Information Frame.
Beside this it may be needed for certain network operations to send out a Node
Information Frame. To issue a NIF execute the following action:
A single click on the Z-Wave sends out a NIF.
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
A double” click on the Z-Wave button wakes up the device.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Firmware-Update over the Air
This device is capable of receiving a new firmware ‘over the air’. The update
function
needs to be supported by the central controller. Once the controller starts
the update
process, perform the following action to confirm the firmware update:
Once the firmware update process has been started on the controller wakeup the device with a double” click. The device will check the firmware request. When accepted the LED will blink to await confirmation on the device. Double click on the button to finally start firmware update.
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 10 | Z-Wave Plus Lifeline |
---|---|---|
2 | 10 | Switching Command. All devices in this group will receive a BASIC SET |
command on Smoke Alarms. Configuration parameter 3 and 4 will define” the BASIC command sent.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 3: Value of ON-Command
This value is sent as BASIC Set to Association Group 2 when an Smoke Alarm
occurs.
Size: 1 Byte, Default Value: 99
SettingDescription
0 – 99 | Value |
---|---|
255 | Value |
Parameter 4: Value of Off-Command
This value is sent as BASIC Set to Association Group 2 when an Smoke Alarm
is cleared.
Size: 1 Byte, Default Value: 99
SettingDescription
0 – 99 | Value |
---|---|
255 | Value |
Technical Data
Dimensions | 115x115x47 mm |
---|---|
Weight | 202 gr |
Hardware Platform | ZM5202 |
EAN | 4251295700342 |
IP Class | IP 20 |
Battery Type | 1 * ER14250 1/2AA |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | 3.05 |
Z-Wave Version | 6.51.09 |
Z-Wave Product Id | 0x0154.0x0004.0x0010 |
Frequency | Europe – 868,4 Mhz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Association Group Information V2
- Association V2
- Battery
- Device Reset Locally
- Firmware Update Md V3
- Manufacturer Specific V2
- Notification V5
- Powerlevel
- Security
- Sensor Binary V2
- Version V2
- Zwaveplus Info V2
Controlled Command Classes
- Basic
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>