Minuteman R100C Rush Carpet Extractor Instruction Manual

June 13, 2024
Minuteman

Minuteman-LOGO

Minuteman R100C Rush Carpet Extractor

Minuteman-R100C-Rush-Carpet-Extractor-PRODUCT

Product Information

Model R100C
Capacity 12 gallon solution tank, 11 gallon recovery tank
Motor Type Dual 2-stage
Operating Pressure 100 psi
Vacuum Power 150
Tank Material Polyethylene
Wheel Type 4 locking wheels
Dimensions (H x L x W) 35″ x 31″ x 18″
Weight 19 lbs
Heating System No Heat
Cord Length 15′
Construction Material Stainless Steel

Product Usage Instructions

Inspection and Unpacking

When your package is delivered, check the carton carefully for signs of rough handling. If your R100C is damaged, notify the carrier immediately and request an inspection.
Be sure to keep the carton, packing inserts, packing lists, and carrier’s receipt until the inspector has verified your claim.

Operating Instructions

Before operating your new R100C, please read the safety instructions provided below:

Safety Instructions

  • The machine was designed for use on carpet cleaning applications as per instructions and recommendations written in this manual. Any deviation from its proper use or purpose and the consequential damage that may occur is the sole responsibility of the end user.
  • Disconnect the power cord from the outlet before servicing. Do not leave the machine connected to an electrical outlet when unattended.
  • Do not immerse or use this machine in standing water. Such use may cause electric shock.
  • When using an extension cord, use only a 3-prong conductor grounding cord-12 gauge wire or heavier.
  • To avoid electric shock, do not expose the unit to rain or snow. Store it indoors in a heated location.
  • Flush and clean solution lines after each day’s use.
  • Use only commercially available carpet cleaning solutions and defoamer intended for use with machines of this type. Do not use dyes, bleaches, ammonia, or other additives.
  • The use of powdered cleaning solution, if not diluted properly, may result in damage to the pump. Powdered chemical is not recommended. If powdered chemicals are used, premix in a separate container before placing in the solution tank.
  • Always read and understand your chemical’s MSDS (Material Safety Data Sheet) before use.
  • This equipment is not designed to handle or use combustible/volatile substances such as gasoline or kerosene, in, on, or near the machine. The use of such materials will cause an extreme hazardous condition.
  • Do not expose the machine to freezing temperatures.
  • All repairs must be done by an authorized MINUTEMAN repair station.
  • Do not use replacement parts other than original MINUTEMAN parts.
  • Do not allow your spray stream to remain in one fixed location as surface damage may occur.
  • Check that all spray nozzles are securely fastened. Loose nozzles could be ejected from equipment at high pressure.

TECHNICAL SPECIFICATIONS

Minuteman-R100C-Rush-Carpet-Extractor-
FIG-7

  • UNPACKING YOUR NEW R100C: When your package is delivered, check the carton carefully for signs of rough handling. If your R100C is damaged, notify the carrier immediately and request an inspection. Be sure to keep the carton, packing inserts, packing lists and carrier’s receipt until the inspector has verified your claim.
  • MINUTEMAN’s liability ceases when the carrier picks up the shipment. However, our customer service staff will be happy to furnish any information needed in connection with the claim and will attempt to expedite a resolution.

PLEASE READ BEFORE OPERATING YOUR NEW R100C:

  • Read the manual carefully and completely before attempting to operate the unit. This manual has important information for the use and safe operation of the machine. Keep this manual handy at all times.
  • This equipment has been engineered and manufactured to provide excellent performance and service. To ensure that your equipment will continue to perform as intended:
  • Maintain equipment regularly- following the suggested maintenance schedule provided.
  • Use only original MINUTEMAN parts when servicing.
  • Operate equipment with care.

If additional information is needed, please contact:

  • MINUTEMAN INTERNATIONAL 630- 627-6900
  • All information and specifications printed in the manual are current at the time of printing; however because of MINUTEMAN’s policy of continual product development, we reserve the right to make changes at any time without notice.
  • FAILURE TO COMPLY WITH THE FOLLOWING WARNINGS AND INSTRUCTIONS WILL VOID THE WARRANTY.

WARNING!

  • The machine was designed for use on carpet cleaning applications as per instructions and recommendations written in this manual. Any deviation from its proper use or purpose and the consequential damage that may occur is the sole responsibility of the end user.

  • Disconnect the power cord from the outlet before servicing. Do not leave machine connected to an electrical outlet when unattended.

  • Do not immerse or use this machine in standing water. Such use may cause electric shock.

  • When using an extension cord, use only a 3-prong conductor grounding cord-12 gauge wire or heavier.

  • To avoid electric shock, do not expose the unit to rain or snow. Store it indoors in a heated location only.

  • Do not use the machine for dry vacuuming.

  • Use defoamer at all times to prevent damage to the vacuum motor.

  • Do not use water in excess of 130°F (54°C) in the solution tank

  • To prevent seal damage and chemical build-up to the pump system, run clean water through the solution lines after each day’s use.

  • Use only commercially available carpet cleaning solutions and defoamer intended for use with machines of this type. Do not use dyes, bleaches, ammonia, or other additives.

  • The use of powdered cleaning solution, if not diluted properly, may result in damage to the pump.

  • Powdered chemical is not recommended. If powdered chemicals are used, premix in a separate container before placing in the solution tank.
    Always read and understand your chemical’sMSDS (Material Safety Data Sheet) before use.

  • This equipment is not designed to handle or use combustible/volatile substances such as gasoline or kerosene, in, on, or near the machine. The use of such materials will cause extreme hazardous condition.

  • Do not expose machine to freezing temperatures.

  • All repairs must be done by an authorized MINUTEMAN repair station.

  • Do not use replacement parts other than original MINUTEMAN parts.

  • Do not allow your spray stream to remain in one fixed location as surface damage may occur.

  • Check that all spray nozzles are securely fastened. Loose nozzles could be ejected from equipment at high speeds.

  • This is not a toy. Keep away from children.

  • Do not pull by the power or use power cord as a handle. Always unplug by grabbing the plug and pulling, do not unplug by pulling the power cord.

  • Inspect cord for damage. Do not use damaged cords. Connect only to properly grounded outlets.

  • Keep hair, fingers, loose clothing, and body parts away from moving parts and openings.

  • Turn off all controls before disconnecting machine

  • Use caution with ejected liquid or chemicals. High pressures and temperatures could be hazardous to nearby people or surroundings.

  • ELECTRICAL – 115 Volt

    • Model: R100C
  • This machine is designed to operate on a standard 15 amp, 120 volt, 60 Hz, AC circuit. Voltages below 105 volt AC or above 125 volts AC could cause serious damage to the motor.

GROUNDING INSTRUCTIONS:

  • This piece of equipment must be grounded. Should an electrical malfunction occur, grounding provides a path of least resistance for electrical current- reducing the risk of electric shock. This piece of equipment is furnished with a cord that has a grounding conductor and grounding plug. The grounded plug must only be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING:

  • Connecting the equipment to an improperly grounded outlet can result in an increased risk of electric shock. A qualified electrician should be consulted if you are unsure that the outlet is properly grounded.
  • Do not modify the plug provided with the equipment. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.
  • This appliance is designed for use on a 120-volt circuit. The grounding plug provided looks like the plug illustrated in Figure 1. Replace the power cord if the grounding pin is damaged or broken.
  • Extension cords connected to this machine should be 12 gauge, three-wire cords with three-prong plugs and outlets. DO NOT use extension cords more than 25 feet (7.6 m) long

MAINTENANCE

  • This R100C has been engineered and built to require minimum maintenance. But like any machine, it does require some care to keep it in optimum working condition. Careful attention to these maintenance instructions will give you maximum operating performance and life expectancy of the machine.

  • CAUTION: Disconnect the power cord from the outlet before doing any clean up or maintenance on the machine

  • Keep the machine clean. Do not allow dust to accumulate on external surfaces or near any moving parts.
    After every job, wipe down the surface of the machine with a clean damp cloth.

  • Inspect cord for damage. Do not use machine with a damaged cord.

PERIODIC MAINTENANCE

  • Use only chemicals safe for extractors
  • Adhere to the appropriate mix ratios for all chemicals
  • For optimal performance, it is suggested that the operator flush the system after every job or at the end of the day.
  • Pump seals and valves may need to be replaced at the 1000 hour mark if a loss in pressure is noted

Daily:

  1. Always keep the machine clean inside and out.
  2. Pour 2 gallons of clean hot water in the solution tank. Turn the pump on and flush the entire system through the wand nozzles for about a minute to pre- vent alkaline build-up.
  3. Remove dirt and lint build-up inside the filter screen in the recovery tank. Lint should be cleaned off so that air flow is not impeded.
  4. Check the solution tank strainer in the solution tank. If lint has accumulated in the screen, remove and rinse it in clear running water.

Weekly:

  1. Check and clean solution filter
  2. Check for obstructions in vacuum pathway

Quarterly:

  1. Check pump, plumbing and fittings for leaks
  2. Check power cords and hoses for tears

CORD STORAGE:

  • While not in use, storage can be accomplished by winding cord around handle assy. Cord should be completely unwound during operation.

CORD SAFETY

  • Do not leave appliance when plugged in. Unplug from outlet when not in use and before servicing
  • Do not use with damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return to service center for inspection and repair.
  • Do not pull or carry by cord, use cord as handle, close a door on cord, or pull cord around sharp edges or corners. Do not run this over cord. Keep cord away from heated surfaces.
  • Do not unplug by pulling cord. To unplug, grasp the plug, not the cord.
  • Do not handle plug or appliance with wet hands.
  • This equipment should be stored indoors and not exposed to rain.
  1. Handle- Used to maneuver and position the R100C. Contains switch box (For switchbox, see #10)
  2. Recovery tank and lid- Tank collects recovered waste water. Lid allows access to recovery tank and creates a seal to ensure suction.
  3. Solution tank and lid- Tank used to store clean water or solution for your job. Lid allows access to the solution tank and prevents external contamination of solution tank.
  4. Non-marking front 4” locking casters and rear 10” wheels
  5. Recovery/vacuum hose inlet barb- connect your recovery vacuum hose to this barb
  6. Solution line Q.D.- Pressurized connection for solu-tion line
  7. Twist lock pigtail- connects to 50ft power cord
  8. Cool air intake for vacuum
  9. Recovery tank dump valve- Pull up to open
  10. Switch box- Two switches marked “VACUUM” and one switch marked “PUMP”. Switches light up when powered on.Minuteman-R100C-Rush-Carpet-Extractor-FIG-3

CLEANING CARPET

  • Using a dedicated dry vacuum, pre-vacuum the space to be cleaned to remove as much dirt as possible. Do not use the extractor to dry vacuum as it does not have a dry filter.
  • Pre-spray the carpet
  • Pour clean water or solution into the solution tank. Do not use water over 130 degrees F.
  • Slide vacuum hose on to the black hose adapter (located at the back of machine) and the wand or upholstery tool.
  • Connect the female on your solution hose to the male Q.D. on the machine.
  • Connect the male end of the solution hose to the wand.
  • Make sure the drain valve (#9 on page 10) is closed by pushing the T-handle all the way in.
  • Always use de-foamer. Previously shampooed carpets usually have a heavy build-up of old shampoo residue which can cause the vacuum system to ingest foam and result in damage to the vacuum motor.
  • Turn on the vacuum and solution switches. Slowly pull the tool towards you with the solution valve trigger engaged. Then make a pass forward and backward with only the vacuum motor on (no spray) over the cleaned area to remove as much dirt and solution as possible. Do not over wet carpet! Make overlapping passes to prevent streaking.
  • If the carpet is heavily soiled, squeeze solution valve lever on the forward pass as well as backwards, allow- ing cleaning solution a few seconds longer to work- prior to vacuuming. Another method is to raise the wand 8″ above the carpet and pre-spray lightly prior to cleaning passes. On extremely soiled carpets, we recommend using a pre-spray solution.
  • When you are close to running out of solution, turn off the pump. Attach the drain elbow on the drain valve. Place a pail under the downspout and pull up the drain valve T-handle. Dirty solution will pour out until the tank is empty. Close the drain valve. Use a clean bucket when you refill the solution tank.
  • When the job is completed, turn the switches off, disconnect the vacuum and solution hoses from the carpet tool and the machine. Drain the recovery tank through the drain valve as before.

CLEANING UPHOLSTERY:

  • Cleaning upholstery with success requires a good knowledge of the type of fabric to be worked on. Look for the cleaning instruction label sewn on the underside of the furniture for the recommended method of cleaning the fabric. If it calls for dry cleaning, do not attempt to clean with the wet extraction method. Otherwise, damage to the fabric could occur. Extraction works perfectly on most synthetic fabrics including synthetic velvets.
  • Before proceeding, test the fabric for colorfastness. Apply a small amount of ready-to-use cleaning solution on the fabric in an inconspicuous spot. Wait for 2 to 3 minutes and rub the area with a white terry cloth towel. If no color comes off the towel, the fabric should be safe to clean. If a little color comes off, there is some risk of colors running when you clean. It may be possible to stabilize colors by cleaning with an acidic rinse.
  • Prepare the machine in the same manner as for carpet cleaning (see CLEANING CARPET), except attach the upholstery tool to the vacuum and the solution hose.
  • Pour hot water into the solution tank. Add recommended amount of cleaning concentrate into the solution tank. Do not use water over 130 degrees F.
  • ‘Turn on the vacuum and pump switches.
  • Clean with the upholstery tool using as little solution as possible. Make overlapping passes to prevent streaking. Go over the area you just cleaned with- out depressing the lever (vacuum only) and gauge the amount of moisture extracted through the view window for dryness. On heavily soiled areas like arm rests, pre-treat with a recommended pre-spray and / or hold the upholstery tool a few inches above the fabric and press lever to spray on the solution before making a pass.

R100C WIRING

Minuteman-R100C-Rush-Carpet-Extractor-
FIG-4Minuteman-R100C-Rush-Carpet-Extractor-
FIG-5

BILL OF MATERIAL

ITEM| PART NO.| QTY| DESCRIPTION| ITEM| PART NO.| QTY| DESCRIPTION
1| F11787-MM| 1| SOLUTION TANK| 23| B00177-1| 4| TERMINAL LUG, FEMALE, QD, 0.25 X 0.032
2| F11788-MM| 1| RECOVERY TANK| 24| B00185- 30| 1| WIRE,14 GA WHITE, UL1015, 10 IN
3| E11124| 1| GASKET, RECOVERY TANK| 25| C02315| 2| LOCKWASHER, #10 INT. STR, SS
4| 12904A| 1| STAND PIPE ASSEMBLY| 26| C00264| 1| NUT, 10-32
4-A| K11965| 1| ELBOW, 180 DEG. FLOAT BALL| 27| C11141| 8| SCREW, ALLEN HEAD, 10-24 X

1.25 IN

4-B| K00672| 1| PVC PIPE, 1.5 X 12 IN, SCH 40 WHT| 28| K00665-1| 1| HOSE ADAPTER, 1.5IN, BLACK
4-C| 10989-2A| 1| FLOAT BALL SCREEN| 29| E11128| 2| GASKET, DRAIN VALVE
4-D| K00741| 1| ADAPTER| 30| K00710| 1| ELBOW, DRAIN VALVE, BLACK
5| F11785-MM| 1| LID, RECOVERY TANK| 31| K00711| 1| DRAIN VALVE, BLACK
6| C12039| 2| WASHER, 1/4 X 1, SS| 32| C00233| 2| WASHER, FLAT, .25 IN
7| C02322| 2| 1/4 X 20 BOLT| 33| C00254| 2| LOCK WASHER, 1/4IN SPLIT
8| B11769| 1| EXTENSION CORD, 12-3 SJTW| 34| C02294| 2| SCREW, 1/4 – 20 X 1.25
9| B12915| 1| VELCRO STRAP| 35| K11185| 1| ELBOW, 90, 1.5 IN, MT-MS, PVC
10| H02548-2| 1| LABEL, IMPORTANT, CORD| 36| K00672-1| 1| PVC PIPE, 1.5 X 2.25 IN,
11| B00185-30| 1| WIRES, 73 IN| 37| E11129| 1| GASKET, BASE
12| B00185-40| 1| WIRES, 73 IN| 38| A00060| 1| 3/8 BARB X 1/4MP, BRASS
13| B010314| 1| WIRE HARNESS| 39| A00052| 1| .25 X .375 M-F 90 DEG
14| F11786-MM| 1| HANDLE| 40| C11244| 1| WASHER, .56 X 1.5 X 0.05
15| B00177| 2| TERMINAL LUG, FEMALE, QD,

0.25 X .032, 16-14 AWG, FULLY

| 41| A00124| 1| HEX NUT, .25 NPT BRASS
16| B00185-40| 1| WIRE,14 GA BLACK, UL1015, 10 IN| 42| D00373| 1| INLET FILTER, .25 NPT
17| C00295-1| 2| #10 X .75IN PAN, BLACK SMS, PHILLIPS| 43| C11143| 2| SCREW, 1/4 – 20 X 1.5 IN, SS
18| C00293| 2| #8 X .5IN PAN, BLACK SMS, PHILLIPS| 44| S11179| 1| NON-SKID TAPE, 1 IN. ROLL
19| D11168| 1| COVER, SWITCHPLATE| 45| F11791- MM| 1| LID, SOLUTION TANK
20| B02211-1| 3| SWITCH, ROCKER, GREEN LIGHT| 46| D13153| 1| STAINLESS STEEL LANYARD
21| D010284| 1| SWITCHPLATE| 47| C00311| 2| SCREW, 8-32 X 3/8
22| E010453| 1| GASKET, SWITCHPLATE| 48| K00666| 1| 90 ELBOW, SCHD 40, 1.5″

Minuteman-R100C-Rush-Carpet-Extractor-FIG-6

BILL OF MATERIAL

ITEM| PART NO.| QTY| DESCRIPTION| ITEM| PART NO.| QTY| DESCRIPTION
1| J13152| 1| DOUBLE GRIP HOSE CLAMP| 27| B00192| 1| MOUNT, NYLON TIE
2| J11863| 1| HOSE, 3 IN| 28| B11606| 1| STRAIN RELIEF, PIGTAIL
3| J00639| 3| SCREW CLAMP, 1.63 – 2.43IN.| 29| K10510| 1| PLUG, 1.25 IN, BLACK
4| J00618| 1| VACUUM HOSE, 2IN GREY, WIRE, 22 IN LG| 30| H03545| 1| COVER, SERIAL # LABEL
5| F11178-BLK| 1| INTERCOOLER, , BLACK| 31| H00565-5| 1| LABEL, SERIAL NUMBER
6| C00273| 16| LOCKNUT, 1/4 X 20, NYLON, SS| 32| C02305| 2| CAP NUT, .5IN PUSH-ON
7| C00233| 22| WASHER, FLAT, .25 IN| 33| C00240| 4| WASHER, SHOULDER, NYLON
8| E00449| 6| GROMMET| 34| G11767| 2| WHEEL, 10 IN
9| C00284| 2| SCREW, 10-32 X .375| 35| D11170| 1| AXLE
10| B11150| 2| GROUND WIRE,| 36| F11789- MM| 1| BASE
11| G00537| 2| VACUUM MOTOR, 82 IN, 115 V| 37| C00314-1| 8| HEX BOLT, 1-4 X 20 X 1IN
12| J00657| 1| HOSE CLAMP, 2 INSLDPRT| 38| G03518-L| 2| LOCKING CASTER, 4 IN
13| J00618| 1| VACUUM HOSE, 2 IN GREY, WIRE, 4 IN LG| 39| J00613B| 1| SOLUTION HOSE, BLACK, 33 IN
14| C00254| 1| LOCK WASHER, 1/4IN SPLIT| 40| J11508| 4| SCREW CLAMP #6, .43 TO
15| C00261| 6| NUT, .25-20, HEX| 41| A00054| 2| ELBOW, 90, .375MP X .375B,
16| D11134-1| 1| VAC PLATE| 42| B00191| 4| NYLON TIE, 11IN BLACK
17| C11189| 5| SCREW, 1-4 X 20 X 4.5 IN,| 43| B00190| 13| NYLON TIE, 4IN
18| C11516| 1| SCREW, 1-4 X 20 X 4.5 IN,| 44| G13761| 1| PUMP, 120 PSI, 115 V
19| C02312| 1| LOCKWASHER, .25 IN., INTER- NAL STAR| 45| D11194| 1| PUMP PLATE
20| H02564-2| 1| LABEL, CAUTION, MOTOR HOUSING| 46| J11154| 1| SOLUTION HOSE, .375 X 14 IN, WIRE REINFORCED
21| A00060| 1| .25 MALE X .375 BARB, BRASS| 47| J00618| 1| VACUUM HOSE, 2 IN GREY, WIRE, 7 IN LG
22| C11244| 2| WASHER, .5 ID X 1,5 OD| 48| E11169| 2| GASKET, VAC MOTOR
23| A00104| 1| QD, 1-4 M X 1-4 FP, BRASS| 49| B00179-2| 1| CLOSED END CNTR, 16-3
24| C11165,| 4| SCREW, #8 X 1 IN, PAN, BLACK| 50| B00179-1| 3| CLOSED END CNTR, 16-3
25| F11790-MM| 1| HEATER, TUNNEL COVER| 51| B11779| 1| 12/3 TWIST LOCK PIGTAIL
26| C00293| 2| #8 X .5IN PAN, BLACK SMS, PHILLIPS|  |  |  |

ELECTRICAL SYSTEM

PROBLEM SOLUTION
NO ELECTRICAL POWER 1.      Defective power cord.

2.      House or building circuit breaker tripped

POWER IS INTERMITTENT TO ONE OR ALL MO- TORS| 1.      Faulty electrical cable.

2.      Defective switches.

3.      Loose terminal or discolored terminal connections.

VACUUM SYSTEM

PROBLEM SOLUTION
NO VACUUM SUCTION 1.      Drain Valve open.

2.      Vacuum lid is not sealed against tank.

3.      Loose vacuum hose, vacuum connection

LOW VACUUM SUCTION| 1.      Accumulated dirt on lid screen.

2.      Worn out vacuum lid gasket.

3.      Lint & dirt build-up on wand head.

4.      Defective vacuum hose.

5.      Loose connection in the vacuum motor(s).

SOLUTION SYSTEM

PROBLEM SOLUTION
PUMP MOTOR RUNS BUT NO SPRAY THROUGH SPRAY TIPS 1.      Clogged spray tips.

2.      Clogged solution intake filter screen.

3.      Clogged female quick disconnect coupler.

4.      Quick disconnects not fully connected

5.      Dirty or damaged pump head valves.

6.      Defective pump check valve.

7.      Crack in pump housing.

8.      Lost Prime.

UNEVEN OR WEAK SPRAY FOR SPRAY TIPS| 1.      Clogged or dirty spray tips.

2.      Accumulated dirt on solution intake filter screen.

3.      Accumulation of debris inside pump and plumbing.

4.      Worn pump bearing (excessive noise).

5.      Punctured pump diaphragm.

6.      Defective rectifier or motor.

7.      Worn nozzles.

ERRATIC PRESSURE| 1.      Pump check valves defective or dirty

2.      Lost prime.

  • Minuteman is a Full Line Manufacturer of Sweepers and Scrubbers, for Industrial Facilities.
  • 14N845 U.S. Route 20, Pingree Grove, IL 60140 USA
  • Phone 800-323-9420 www.minutemanintl.com
  • A Member of the Hako Group

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals