Instructions INSTALLATION INSTRUCTIONS
RTE0RFB
WIRELESS DIGITAL ROOM THERMOSTAT AND RECEIVER
View all NEOMITIS thermostat manual
PACK CONTAINS
INSTALLATION – RECEIVER
For best performance, do not mount the receiver on metal wall boxes and leave
at least 30 cm distance from any metal objects including wall boxes and boiler
housing.
MOUNTING OF WALL MOUTING PLATE
The receiver is fixed on the wall with the standard wall plate which is
supplied with the product.
-
Unscrew the 2 screws under the receiver.
-
Remove the wall plate from the receiver.
-
Secure the wall plate with the two screws provided using the horizontal and vertical holes.
-
In case of surface mounting, a knock-out area is provided on the wall plate and on the corresponding area of the receiver.
WIRING
All electrical installation work should be carried out by a suitably qualified
Electrician or other competent person. If you are not sure how to install this
thermostat consult either with a qualified electrician or heating Engineer. Do
not remove or refit the receiver onto the backplate without the mains supply
to the system being isolated.
All wiring must be in accordance with IEE regulations. This product is for
fixed wiring only.
N = Neutral
L =Live
1 = Not used
2 = Not normally used
3 = Common – Power In 230V
4 = Call for heat – Power out 230VN = Neutral
L =Live
1 = Not used
2 = Not normally used
3 = Common – Power In: Voltage Free Connections
4 = Call for heat – Power Out. Voltage Free Connections
NOTE: The unit is double in insulated so does not require and earth but a
terminal is supplied for the spare wire.
MOUNTING OF THE RECEIVER
1- Replace the receiver on the wall mounting plate. 2- Secure the receiver by screwing the both locking screws under the receiver.
INSTALLATION -THERMOSTAT
Recommended locations for your thermostat.
To ensure that your thermostat provides accurate readings and controls
effectively, it must be installed approximately 1.5 m above floor level on an
inside wall, away from direct sunshine and any other sources of heat or cold
such as radiators, cold draughts, etc.
NB: In order to ensure
proper operation of the product, ensure that the thermostat is not positioned
near to an area which could be affected by interference from another source.
E.g.: a wireless transmitter or receiver, TV, PC, etc.
Important: The thermostat measures the temperature of the place where it
is installed. It does not take into account the temperature differences that
may exist between diffe-rent locations in the house if the temperature is not
uniform.
INSTALLING BATTERIES
-
Remove the batteries cover which is placed on the front of thermostat.
-
Insert the 2 batteries AA supplied.
Note the cor-rect polarity according to the engraving on the thermostat when inser-ting the batteries. -
Replace the batteries cover.
MOUNTING OF THERMOSTAT
• On the wall
-
Unscrew the 2 screws under the thermostat.
-
Remove the wall plate from the thermostat.
-
Secure the wall plate with the two screws provided using the horizontal and vertical holes.
-
Replace the thermostat on the wall mounting plate.
-
Secure the thermostat by screwing the locking screws under the thermostat.
• On the table stand
-
Insert the 2 pins inside the wallplate.
-
Slide the stand to the right.
-
Fold the stand and lock it into the wallplate.
-
Tilt the thermostat according to its placement in the room. 2 tilts are available.
The thermostat and the receiver are not bonded together at the factory. To bond the transmitter and the receiver together, proceed as below:
-
Press and hold for 5 seconds the RF test button on the receiver. RF test green light is blinking.
-
Within 1 minute, press and hold for 5 seconds the RF test button on the thermostat. Pairing icon is flashing.
-
The thermostat RF icon and receiver green light are blinking.
-
Thermostat RF icon and receiver green light will be solid when pairing is complete.
Note: the receiver is usually located near your boiler.
If you want to check the signal strength, press and release the RF test
button. The RF icon blinks and the signal strength appears. 10 is the best
signal strength.
OPERATING STATES OF THE SYSTEM
States of the indicator light | Operating states of the thermostat |
---|---|
Green | Receiver is connected to the thermostat |
Orange | System is calling for heat |
Red | RF Signal has been lost, no connection between thermostat and receiver. |
In order to re-bond the thermostat and receiver refer to the installation instructions (page 2).
TROUBLESHOOTING
Display disappears on thermostat.
– Check batteries.
– Replace the 2 batteries. Only use alkaline 1.SV AA (LR6) batteries.
Do not use rechargeable batteries.
The heating does not come on or does not go off.
– Your room thermostat may have been set up close to a source of heat or on a
cold wall – put it in a recommended location (see the “Installing” section on
page 2 for these locations).
– Check that the radio communication works between the thermostat and the
receiver.
– Check if the boiler controlled by the programmable room thermostat is
properly connected to the receiver.
Radio transmission is not working properly:
-
The receiver is not picking up the code sent by the thermostat.
– Check and replace thermostat batteries. -
The receiver does not recognize transmitter’s code.
– Pair the room thermostat transmitter with the receiver again See Pairing section. -
The receiver or the transmitter is affected by interference:
– Re site the transmitter.
– If possible, re site the receiver away from the source of the interference.
The radio link between the thermostat and the receiver is lost.
– Check the battery level status.
– Check that the radio communication works between the thermostat and the
receiver.
If the radio communication does not work between the receiver and the
thermostat.
– Repeat the pairing between the thermostat and receiver (refer to the user
instruc-tions).
The thermostat does not control properly.
– Thermostat sensor may be influenced by a source of heat or cold.
– Check that the radio communication works between the thermostat and
receiver.
If the problem persists, contact your installer.
TECHNICAL SPECIFICATIONS
Power supply: 2 alkaline 1.5 V AA (LR6) batteries.
Manual temperature setting range: from +5C to +30°C.
Battery life: approx. 2 years.
Receiver:
- Power supply: 230V50/60Hz.
- Relay outputs: 5(2)A.
- Rated impulse voltage: 4000V.
- Micro-disconnection: Type 1B.
- Pollution degree: 2.
- Automatic action: 100,000 cycles.
- Class II.
Maximum range in the home: 15m is typical but this varies depending on the
building construction eg plasterboard lined with metal foil the number of
walls and ceilings that
the signal has to pass through and by the surrounding electromagnetic
environment.
Signal sending: every 10 minutes, maximum time lag 1 minute after the set-
point temperature has been changed.
Environment :
– Operation temperature: 0°C to +40°C.
– Storage temperature: from -10C to +60°C.
– Humidity: 80% at +25°C (without condensation)
– Protection rating: IP30.
N.B.: this room thermostat is one part of a complete radio system and will
only work with the 230V AC receiver. Radio emitter, frequency from 2.40 to
2.48 GHz.
UKCA declaration of conformity: We, Neomitis Ltd, hereby declare under
our sole responsibility that the products described in these instructions
comply with statutory instruments 2017 No. 1206 (Radio Equipment Regulations),
2012 n”3032 (ROHS) and following designated standards listed below:
– 2017 No. 1206 (Radio Equipment Regulations):
– Article 3.la: Article 3.la: EN 60730-1:2011, EN 60730-2-9:2010, EN
62311:2008
– Article 3. lb: EN 301489-1 Vl.9.2
– Article 3.2 : EN 300 440 V2.1.1
– The Restriction of the Use of Certain Hazardous Substances in Electrical and
Electronic
Equipment Regulations 2012 (2012 No.3032) : EN IEC 63000:2018.
Neomitis Ltd: 16 Great Queen Street, Covent Garden, London, WC2B SAH UNITED
KINGDOM – contactuk@neomitis.com
EU declaration of conformity: We, Imhotep Creation, hereby declare under
our sole responsibility that the products described in these instructions
comply with the provisions of Directives and harmonized standards listed
below:
– RED:
– Article 3.la (Safety): EN60730-1:2011 / EN60730-2-9: 2010 / EN62311:2008
– Article 3.lb (EMC): ETSI EN 301489-1 V2.2.1(2019-03)/ ETSI EN 301489-3
V2.1.1
– Article 3.2 (RF): ETSI EN 300440 V2.1.1(2017)
– Ro HS 2011/65/UE, amended by Directives 2015/863/UE & 2017/2102/UE: EN IEC
63000:2018
Imhotep Creation: ZI Montplaisir – 258 Rue du champ de courses – 38780 Pont-
Ev~que
France – contact@imhotepcreation.com
Neomitis Ltd and Imhotep Creation belong to Axenco Group.
Control class and energy contribution, according to ERP 2009/125/EC and
related regulations
Class IV-PID Room Thermostat, for use with on/off heating devices.
Electronic room thermostat that controls both the cycle time of the thermostat
and the ratio between on and off periods during the same cycle of the heating
device, depending on the room temperature. PID control reduces the average
water temperature, improves the accuracy of room temperature control and
increases system efficiency.
The symbol , affixed on the product indicates that you must dispose of it at the end of its useful life at a special recycling point, in accordance with European Directive WEEE 2012/19/EU. If you are replacing it, you can also return it to the retailer from which you buy the replacement equipment. Thus, it is not ordinary household waste. Recycling products enables us to protect the environment and to use less natural resources.
Neomitis RTE0RFB WIRELESS DIGITAL ROOM THERMOSTAT Installation Manual
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>