PACK CONTAINS
**Thermostat x1
**
AA Batteries (LR6) x2
Screw Anchor x2
Screws x2
INSTALLATION
Recommended locations for your thermostat
To ensure that your ther- mostat provides accurate readings and controls effec- tively, it must be installed approximately 1.5 m above floor level on an inside wall, away from direct sunshine and any other sources of heat or cold such as radiators, cold draughts, etc.
Important: The thermostat measures the temperature of the place where it
is installed. It does not take intoaccount the temperature differences that
may exist between different locations in the house if the temperature is not
uniform.
INSTALLING BATTERIES
-
Remove the batteries cover which is placed on the front of thermostat
-
Insert the 2 batteries AA supplied. Note the correct polarity according to the engraving on the thermostat when inserting the batteries
-
Replace the batteries cover
MOUNTING OF WALL MOUTING PLATE
The digital room thermostat is fixed on the wall with the wall plate which is supplied with the product
-
Unscrew the 2 screws under the thermostat
-
Remove the wall plate from the ther- mostat
-
Secure the wall plate with the two screws provided using the horizontal and vertical holes
WIRING
All electrical installation work should be carried out by a suitably qualified Electrician or other competent person. If you are not sure how to install this thermostat consult either with a qualified electrician or heating En- gineer. Do not remove or refit the appliance onto the backplate without the mains supply to the system being isolated.
All wiring must be in accordance with IEE regulations. This product is for
fixed wiring only.
C OM= Live
NC= Normally closed switch out (Satisfied)
NO = Normally open switch out (call for heat)
MOUNTING OF THE THERMOSTAT
-
Replace the thermostat on the wall mounting plate
-
Secure the thermostat by screwing the both locking screws under the thermostat
TROUBLESHOOTING
Display disappears on thermostat.
- Check batteries.
- Replace the 2 batteries. Only use alkaline 1.5V AA (LR6) batteries. Do not use rechargeable batteries.
Do not use rechargeable batteries.
The heating does not come on or does not go off.
- Your room thermostat may have been set up close to a source of heat or on a cold wall − put it in a recommended location (see the “Installing” section on page 1 for these locations).
- Check that the communication works between the thermostat and the boiler
TECHNICAL SPECIFICATIONS
- Power supply: 2 alkaline 1.5 V AA (LR6) batteries.
- Battery life: approx. 2 years.
- Relay outputs: 5(2)A.
- Rated impulse voltage: 4000V.
- Micro disconnection: Type 1B.
- Pollution degree: 2.
- Automatic action: 100,000 cycl
- Class II.
Note: It is recommended to replace annually as part of the normal system service and
before leaving the property empty for a prolonged period.
Environment
- Operation temperature: 0˚C to +40˚C.
- Manual temperature setting range: from +5˚C to +30˚C.
- Storage temperature: from −10˚C to +60˚C.
- Humidity: 80% at +25˚C (without condensation)
- Protection rating: IP30
UKCA declaration of conformity: We, Neomitis Ltd, hereby declare under our sole responsibility that the products described in these instructions comply with statutory instruments 2016 No.1101 (Electrical Equipment safety Regulations), ), 2016 No.1091 (Electromagnetic Compatibility
Regulations) , 2012 n˚3032 (ROHS) and following designated standards
- 2016 No.1101 (Safety): EN 60730−1:2011, EN 60730−2−9:2010, EN 62311:2008
- 2016 No.1091 (EMC): EN 60730−1:2011/ EN 60730−2−9:2010
- 2012 n˚3032 (ROHS): EN IEC 63000:2018
Neomitis Ltd: 16 Great Queen Street, Covent Garden, London, WC2B 5AH UNITED KINGDOM − contactuk@neomitis.com
EU declaration of conformity: We, Imhotep Creation, hereby declare under our sole responsibility that the products described in these instructions comply with th provisions of Directives and harmonized standards listed below
- − Article 3.1a (Safety): EN60730−1:2011/ EN60730−2−9:2010 / EN62311:2008
- Article 3.1b (EMC): EN60730−1:2011/ EN60730−2−9:2010
- RoHS 2011/65/UE, amended by Directives 2015/863/UE & 2017/2102/UE : EN IEC 63000:2018
Imhotep Creation: ZI Montplaisir − 258 Rue du champ de courses − 38780 Pont−Evêque − France − contact@imhotepcreation.com Neomitis Ltd and Imhotep Creation belong to Axenco Group.
Control class and energy contribution, according to ERP 2009/125/EC and
related regulations
Class IV − PID Room Thermostat, for use with on/off heating devices. Electronic room thermostat that controls both the cycle time of the thermostat and the ratio between on and off periods during the same cycle of the heating device, depending on the room temperature. PID control reduces the average water temperature, improves the accuracy of room temperature control and increases system efficiency.
The symbol __, affixed on the product indicates that you must dispose of it at the end of its useful life at a special recycling point, in accordance with European Directive WEEE 2012/19/EU. If you are replacing it, you can also return it to the retailer from which you buy the replacement equipment. Thus, it is not ordinary household waste. Recycling products enables us to protect the environment and to use less natural resources.
OVERVIEW
Thank you for purchasing our RTO, digital room thermostat with PID and backlight. It is by listening to your requirements we have created and designed our products to be easy to operate and install. The thermostat is designed to make your life easier by helping you to save energy and money through ease of operation.
CONTROLS AND DISPLAY
- THERMOSTAT
SETTINGS
INSTALLING BATTERIES
-
Remove the batteries cover which is placed on the front of thermostat
-
Insert the 2 batteries AA supplied. Note the cor- rect polarity according to the engraving on the thermostat when inser- ting the batteries.
-
Replace the batteries cover.
INITIAL POWER UP
-
Once batteries are fitted all symbols will be displayed on the LCD screen as shown for two seconds.
-
After 2 seconds, the LCD will light upand show :
- The ambient temperature (˚C) solid.
- The icon is solid when the heating is turned ON.
- The setpoint temperature (˚C) solid.
Note: When the batteries must be changed, a low battery level indicator
lights up on the device.
Remember to take used batteries to battery collection points so they can be
recycled.
OPERATING
TEMPERATURES SETTING
The desired temperature can be set.
To set the temperature, turn the dial clo- ckwise, to increase the temperature, turn the dial counter−clockwise, to decrease the temperature.
The default temperature is 2O˚C (68˚F).
FACTORY SETTINGS
Settings | Factory settings |
---|---|
Set temperature | 20°C |
Note : To restore factory settings, press and hold down this part for more than 3 seconds using the tip of a pen.
All LCD display will be turned ON for 2 seconds and the factory settings will be res- tored.
TROUBLESHOOTING
The boiler is not heating:
- Check that the Thermostat is calling for heat if yes then the thermostat would appear to be working check that the boiler has not switched itself off. If no increase set temperature.
- Check the position of the batteries. Remove them for 3O seconds and reinsert them. If the problem persists, replace the 2 batteries.
Nothing in the display :
- Check the position of the batteries. Remove them for 3O secondes and reinsert them. If the problem persists, replace the 2 batteries.
The room temperature is not high enough, the boiler is not providing
enough heat:
- Check the active desired temperature and increase it if needed (see page 1).
You made a mistake while setting:
-
You just need to restore factory settings, as explained in the “Factory settings” section (see page 2). This will reverse any changes you might have made.
-
The system is not heating but is on:
-
If and indicator light is on but the system remains cold, then you should contact your installer.
If the problem persists, then contact your installer.
The system is not heating but is on:
- If and indicator light is on but the system remains cold, then you should contact your installer.
If the problem persists, then contact your installer.
TECHNICAL SPECIFICATIONS
Please refer to the installing instructions for any informations about batteries life, stan- dards and product environment.
WHAT IS A ROOM THERMOSTAT
… an explanation for householders
A room thermostat simply switches the heating system on and off as necessary.
It works by sensing the air temperature, switching on the heating when the
aitemperature falls below the thermostat setting, and switching it off once
this set temperature has been reached.
Turning a room thermostat to a higher set- ting will not make the room heat up
any faster. How quickly the room heats up de- pends on the design of the
heating system, for example, the size of boiler and radiators. Neither does
the setting affect how quickly the room cools down.
Turning a room thermostat to a lower setting will result in the room being
controlled at a lower temperature, and saves energy.
The heating system will not work if a time switch or programmer has switched
it off. The way to set and use your room thermostat is to find the lowest
temperature setting that you are comfortable with, and then leave it alone to
do its job. The best way to do this is to set the room thermostat to a low
temperature − say 18ºC − and then turn it up by one degree each day until you
are comfortable with the temperature. You won’t have to adjust the thermostat
further. Any adjustment above this setting will waste energy and cost you more
money.
If your heating system is a boiler with radiators, there will usually be only
one room thermostat to control the whole house. But you can have different
temperatures in indi- vidual rooms by installing thermostatic radiator valves
(TRVs) on individual radiators. If you don’t have TRVs, you should choose a
temperature that is reasonable for the whole house. If you do have TRVs, you
can choose a slightly higher setting to make sure that even the coldest room
is comfortable, then prevent any overheating in other rooms by adjusting the
TRVs.
Room thermostats need a free flow of air to sense the temperature, so they
must not be covered by curtains or blocked by furniture. Nearby electric
fires, televisions, wall or table lamps may prevent the thermostat from
working properly.
WHAT IS PID
The PID feature works by using a formula to calculate the difference between the de- sired temperature setpoint and current ambient temperature, the PID feature then predicts how much power to use to ensure the ambient temperature remains as close to the temperature setpoint as possible by eliminating the impact of environmental temperature changes
Costumer Support
NEOMITIS® LIMITED – 16 Great Queen Street, Covent Garden, London, WC2B 5AH
UNITED KINGDOM
Registered in England and Wales No: 9543404
Tel+44(0)2071250236 -Fax+44(0)2071250267
-E-mail:constact@neomitis.com
Neomitis RTE0B WIRED DIGITAL ROOM THERMOSTAT INSTALLATION INSTRUCTIONS