i safe MOBILE M93A01 IS930.2 Industrial Tablet Instruction Manual

June 8, 2024
i safe MOBILE

i safe MOBILE M93A01 IS930.2 Industrial Tablet

SAFETY INSTRUCTIONS
IS930.2
MODEL M93A01

SAFETY INSTRUCTIONS

EX MARKINGS
ATEX:
II 3G Ex ic IIC T4 Gc IP64
II 3D Ex ic IIIC T135°C Dc IP64
Certificate of Conformity :
EPS 19 ATEX 1 072 X
CE-designation:
IECEx:
Ex ic IIC T4 Gc IP64
Ex ic IIIC T135°C Dc IP64
IECEx Certificate: IECEx EPS 19 .0035X
UKEX:
II 3G Ex ic IIC T4 Gc IP64
II 3D Ex ic IIIC T135°C Dc IP64
CML 21UKEX2491X
UKCA-designation:

North America:
Class I Div 2 Groups A, B, C, D, T4
Class II Div 2 Groups F, G , T135˚C
Class III Div 2
CSA20CA70220244
Temperature range:
-20°C …+60°C (EN/IEC 60079-0)
-10°C …+55°C (EN/IEC 62368-1)
Manufactured by:
i.safe MOBILE GmbH
i_Park Tauberfranken 10
97922 Lauda-Koenigshofen
Germany

EX-RELEVANT SAFETY REGULATIONS

Use of this device assumes that the operator observes the conventional safety regulations and has read and understood manual, safety instructions and certificate .
The following safety regulations must also be complied with:

  • Inside ex-hazardous areas the covers of all interfaces must be closed .
  • To ensure the IP-protection, it has to be ensured that all gaskets are present and functional . There must be no large gap between the two halves of the housing .
  • The device may only be charged outside ex-hazardous areas .
  • Physical connections to equipment are only allowed outside ex-hazardous areas using equipment approved by i.safe MOBILE GmbH.
  • The device may only be charged at ambient temperatures between +5°C . . . +35°C .
  • The device may not be exposed to any aggressive acids or alkalis .
  • The device may only be used in zones 2 or 22 .
  • Only accessories approved by i.safe MOBILE GmbH may be used .

EX-RELEVANT SAFETY REGULATIONS FOR NORTH AMERICA
Conditions of Acceptability:

  • The battery may be charged outside explosion hazardous areas only using approved external adapter model ICP12-050-2000B with output rated 5Vdc, 2A or other external approved AC/DC adapter which also complies with the requirements of LPS and has output rated 5Vdc, 2A .
  • Physical connections to other equipment are only allowed outside ex-hazardous areas .
  • Opening of any interface or connector covers in explosive atmosphere is not permitted .
  • The product has been evaluated with rechargeable Li-ion battery pack model MBP93A01 . The battery is not considered interchangeable .
  • The device must be protected against excessive UV light emission and high electrostatic processes .
  • The maximum rated operating temperature for charging is 35°C .

INFORMATION CONCERNING SAR CERTIFICATION (SPECIFIC ABSORBATION RATE)
Maximum SAR for this model and conditions under which it was recorded:
SAR (body – worn) 1 .53 W/kg

NB WARNING
CAUTION

  • Use careful with the earphone maybe possible excessive sound pressure from earphones and headphones can cause hearing loss
  • CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE . DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS .
  • Operation temperature: -20°C …+60°C (EN/IEC 60079-0)/ -10°C …+55°C (EN/IEC 62368-1) .
  • The device shall only be connected via accessory authorised by i.safe MOBILE GmbH . AC Adapter: Approved external adapter model ICP12-050-2000B (Input:
  • AC100-240V 50/60Hz 0 .3A; Output: 5VDC, 2A) or other approved external AC/DC adapter which complies with the requirements of LPS (Limited Power Source) and has output rated 5VDC/2A . Adapter shall be installed near the equipment and shall be easily accessible . The plug is considered independent of the adapter .
  • The device complies with RF specifications when the device used at 0 .5 cm from your body .

The i.safe MOBILE GmbH hereby declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU . This information has to be presented in such a way that the user can readily understand it . Typically, this will necessitate translation into every local language (required by national consumer laws) of the markets where the equipment is intended to be sold . Illustrations, pictograms and using international abbreviations for country names may help reduce the need for translation .

EU/UK-DECLARATION OF CONFORMITY
EU/UK – Declaration of Conformity
according to directive 2014/34/EU, SI 2016 No. 1107, 2014/53/EU, SI 2017 No. 1206,
2011/65/EU (2015/863/EU), SI 2012 No. 3032
The company i.safe MOBILE GmbH declares under its sole responsibility that the product to which this declaration relates is in accordance with the provisions of the following data, directives and standards:

Name & address of the manufacturer in the EU| i.safe MOBILE GmbH i_Park Tauberfranken 10 97922 Lauda – Koenigshofen Germany
---|---
Description of the device| Explosion protected tablet
type / Typ: IS930.2
model / Modell: M93A01
Ex – marking| II 3G Ex ic IIC T4 Gc IP64
II 3D Ex ic IIIC T135°C Dc IP64
Conformity statement 2014/34/EU issued by

Applied harmonized standards

| EPS 19 ATEX 1 072 X
Bureau Veritas
Consumer Products Services Germany GmbHOehleckerring 40 22419 Hamburg, Germany
identification number / Kenn-Nummer: 2004 EN IEC 60079-0:2018; EN 60079-11:2012
Conformity statement SI 2016 No. 1107 issued by

Applied standards

| CML 21UKEX2491X
Eurofins E&E CML Limited, Newport Business Park, New Port Road, Ellesmere Port, CH65 4LZ, United Kingdom identification number / Kenn-Nummer: 2503 EN IEC 60079-0:2018; EN 60079-11:2012
Conformity statement 2014/53/EU issued by| PHOENIX TESTLAB GmbH
Königswinkel 10
32825 Blomberg, Germany
identification number / Kenn-Nummer: 0700
EN 62368-1:2014/A11:2017;
EN 50332-1:2013; EN 50332-2:2013;
EN 50566:2017; EN 62209-2:2010+A1:2019;
EN 62479:2010; EN 50663:2017;
EN IEC 62311:2020; ETSI EN 301 489-1 V2.2.3;
ETSI EN 301 489-3 V2.1.1;
ETSI EN 301 489-17 V3.2.4;
ETSI EN 301 489-19 V2.1.1;
Draft ETSI EN 301 489-52 V1.1.0;
EN 55032:2015+A11:2020;
EN 55035:2017+A11:2020;
ETSI EN 301 511 V12.5.1;
ETSI EN 301 908-1 V13.1.1;
ETSI EN 301 908-2 V13.1.1;
ETSI EN 301 908-13 V13.1.1;
ETSI EN 300 328 V2.2.2;
ETSI EN 301 893 V2.1.1;
ETSI EN 300 440 V2.2.1;
ETSI EN 300 330 V2.1.1;
ETSI EN 303 413 V1.1.1
Conformity statement SI 2017 No. 1206 issued
by Applied standards| MiCOM Labs
575 Boulder Court
Pleasonton
California 94566, USA

EN 62209-2:2010+A1:2019; EN 50566:2017;
EN 50360:2017; EN 62479:2010;
EN 50663:2017; EN IEC 62311:2020;
EN 62368-1:2014+A11:2017; EN 50332-1:2013;
EN 50332-2:2013; EN 301 489-1 V2.2.3;
EN 301 489-17 V3.2.4; EN 301 489-19 V2.1.1;
EN 301 489-3 V2.1.1;
Draft EN 301 489-52 V1.1.0;
EN 55032:2015+A11:2020;
EN 55035:2017+A11:2020;
EN 301 511 V12.5.1; EN 301 908-1 V13.1.1;
EN 301 908-2 V13.1.1; EN 301 908-13 V13.1.1;
EN 300 328 V2.2.2; EN 301 893 V2.1.1;
EN 303 413 V1.1.1; EN 300 330 V2.1.1;
EN 300 440 V2.2.1

Conformity statement 2015/863/EU amending
2011/65/EU issued by Applied harmonized standards| SGS-CSTC Standards Technical Services Co.,
Ltd. Guangzhou Branch No. 198 Kezhu Road, Scientech Park,
Guangzhou Economic & Technology Development District
Guangzhou, Guangdong Province, 510663 China
IEC 62321-2: 2013; IEC 62321-1: 2013;
IEC 62321-3-1: 2013; IEC 62321-5: 2013;
IEC 62321-4: 2013 + A1: 2017;
IEC 62321-7-1: 2015;
IEC 62321-7-2: 2017 & ISO 17075-1: 2017;
IEC 62321-6: 2015;
IEC 62321-8: 2017
Conformity statement SI 2012 No. 3032 issuedby Applied standards| SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
No. 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology
Development District
Guangzhou, Guangdong Province, 510663 China
IEC 62321-2: 2013; IEC 62321-1:2013;
IEC 62321-3-1:2013;
IEC 62321-4:2013+A1:2017; IEC 62321-5:2013;
IEC 62321-7-1:2015; IEC 62321-7-2:2017;
ISO 17075-1:2017; IEC 62321-6:2015;
IEC 62321-8:2017
CE/UKCA Marking|

Lauda – Koenigshofen 27.10.2022

Dirk Amann
Managing Director
Geschäftsführer
1041CC14REV00_cmu All rights reserved, i.safe MOBILE GmbH ument No . 1041MM11REV01
Version: 2022-10-27
(c) 2022 i.safe MOBILE GmbH
i .safe MOBILE GmbH i_Park Tauberfranken 10
97922 Lauda-Koenigshofen
Germany
Tel . +49 9343 60148-0
info@isafe-mobile.com
www.isafe-mobile.com
Template: TEMPMM01REV10
WWW.ISAFE-MOBILE.COM

Documents / Resources

| i safe MOBILE M93A01 IS930.2 Industrial Tablet [pdf] Instruction Manual
M93A01 IS930.2 Industrial Tablet, M93A01, IS930.2 Industrial Tablet, Industrial Tablet, Tablet
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

i safe MOBILE User Manuals

Related Manuals