i safe MOBILE IS-TH1xx.2 Barcode Scanner Trigger Handle Instruction Manual

June 8, 2024
i safe MOBILE

IS-TH1xx.2 Barcode Scanner Trigger Handle
Instruction Manual
i safe MOBILE IS-TH1xx.2 Barcode Scanner Trigger
Handle

IS-TH1xx.2 Barcode Scanner Trigger Handle

Document No. 1054MM01REV02
Version: 2022-10-27 (c) 2022 i.safe MOBILE GmbH
i.safe MOBILE GmbH i_Park Tauberfranken 10 97922 Lauda-Koenigshofen
Germany
Tel. +49 9343 60148-0
info@isafe-mobile.com
www.isafe-mobile.com
This Operating Manual complies with these standards: IEC 60079, IEC 82079, ANSI Z535.6
Diese Bedienungsanleitung erfüllt die Anforderungen der folgenden Normen:
IEC 60079, IEC 82079, ANSI Z535.6

READ AND UNDERSTAND THE INSTRUCTIONS
**PROTECT YOUR LIFE AND READ THE OPERATING MANUAL**
This Operating Manual is part of the device IS-TH1xx.2 (model MTHA10 / MTHA11). This Operating Manual provides important information for safe use of the device.

  • Before using the device, read this Operating Manual carefully and pay particular attention to the “Safety” section and the warnings highlighted with the warning symbol.
  • Make sure you have access to this Operating Manual when you need it. You can find the current Operating Manual at www.isafe-mobile.com/en/support/downloads
  • Follow all instructions given on the device and on the packaging.
  • Follow local safety regulations.

INTENDED USE
The device IS-TH1xx.2 is used for scanning barcodes. The device IS-TH1xx.2 is suitable for use in potentially explosive atmospheres classified zone 2/22 in accordance with directives 2014/34/EU, SI 2016 No. 1107 and 1999/92/EC, as well as the IECEx scheme.
Only use the device as described in this Operating Manual. Any other use is considered improper and can lead to death, severe injuries and damage to the device.
The manufacturer i.safe MOBILE GmbH does not assume any liability for damage caused by improper use. The warranty expires in the event of improper use.
WARRANTY
You can find the warranty conditions at www.isafe- mobile.com/en/support/service
EX MARKINGS

ATEX:
II 3G Ex ic op is IIC T4 Gc
II 3D Ex ic op is IIIC T135°C Dc
EU Type Examination Certificate:
EPS 21 ATEX 1 082 X
CE-designation:| North America:
Class I Div 2 Groups A, B, C, D, T4
Class II Div 2 Groups F, G, T135˚C
Class III Div 2
CSA21CA80083773X
---|---
IECEx:
Ex ic op is IIC T4 Gc
Ex ic op is IIIC T135°C Dc
IECEx Certificate: IECEx EPS 21.0028X| Temperature range:
-20°C … +60°C (EN/IEC 60079-0)
-10°C … +50°C (EN/IEC 62368-1)
UKEX:
II 3G Ex ic op is IIC T4 Gc
II 3D Ex ic op is IIIC T135°C Dc
UK Type Examination Certificate: CML 21UKEX21327X
UKCA-designation:| Manufactured by:
i.safe MOBILE GmbH
i_Park Tauberfranken 10 97922 Lauda-Koenigshofen
Germany

EU/UK DECLARATION OF CONFORMITY
You will find the EU/UK declaration of conformity at the end of this Operating Manual or at www.isafe-mobile.com/en/support/downloads
PRODUCT COMPLIANCE FOR NORTH AMERICA
Conforms to: STD UL 62368-1, STD UL 913
Certified to: CSA STD CSA C22.2#60079-0, CSA STD CSA C22.2#60079-11, CSA STD CSA C22.2#62368-1
DEVICE OVERVIEW![i safe MOBILE IS-TH1xx.2 Barcode Scanner Trigger Handle

NAME CONCEPT
The two “xx” in IS-TH1xx.2 are placeholders. The IS-TH1xx.2 comes in two variants with different scan ranges and scan engines:

name (model) scan range scan engine
IS-TH1MR.2 (MTHA10) mid range Zebra SE4750 (MR)
IS-TH1ER.2 (MTHA11) extended range Zebra SE4850 (ER)

SAFETY

Read the “Safety” section of this Operating Manual carefully before using the device. If you do not follow these instructions or do not understand them, this could lead to death, severe injuries and damage to the device.
USER
Only trained users who are qualified in the use of Ex devices in explosion hazardous areas and who have read and understood this Operating Manual may use this device.
EX-RELEVANT SAFETY REGULATIONS

  • Use of this device assumes that the operator observes the conventional safety regulations and has read and understood Operating Manual, Safety
  • Instructions and certificate. When used in explosion hazardous areas, the following Safety Instructions must also be complied with:
  • The device may be connected only outside ex-hazardous areas to the IS530.2 via the ISM interface.
  • To ensure the IP-protection, it has to be ensured that all gaskets are present and functional. There must be no large gap between the two halves of the housing.
  • The device must be securely fastened to the ISM interface when used in ex-hazardous areas.
  • The device may not be exposed to any aggressive acids or alkalis.
  • The device may only be used in zones 2 or 22.
  • Only accessories approved by i.safe MOBILE GmbH may be used.

EX-RELEVANT SAFETY REGULATIONS FOR NORTH AMERICA
Conditions of Acceptability:

  • The Barcode Scanner IS-TH1xx.2 must be protected from impacts with high impact energy, against excessive UV light emission and high electrostatic charge processes.
  • The 13-Pin connector of the IS-TH1xx.2 may only be assembled or disassembled from the ISM interface outside hazardous areas.
  • The 2 pin charging contacts of the IS-TH1xx.2 should only be used in non-hazardous locations.
  • Unauthorized repair is not allowed.
  • Apparatus is for use in pollution degree 2 or better.
  • Only designated charger may be connected to the charging contacts.
  • Not suitable for hazardous locations when enclosure is damaged.

USE IN EXPLOSION HAZARDOUS AREAS
DANGER
Improper use can result in death or severe injuries!

  • Only use the device in explosion hazardous areas of zones 2/22 or outside of explosion hazardous areas.
  • Only connect the device outside explosion hazardous areas to the ISM interface of the IS530.2.

Before entering an explosion hazardous area with the device,

  • make sure that the device is securely fastened to the ISM interface of the IS530.2,
  • make sure that no gap can be seen between the two halves of the device,
  • make sure the device is not damaged,
  • make sure that all the labels on the device are readable.

If you use the device in an explosion hazardous area, read and follow the instructions in the “Possible User Errors” section.
Switch off the device immediately and leave the explosion hazardous area without delay if

  • malfunctions occur on the device,
  • you have damaged the housing of the device,
  • you have exposed the device to excessive loads,
  • the labels on the device are no longer readable.

POSSIBLE USER ERRORS
DANGER
Improper use can result in death or severe injuries! Follow the instructions below:

  • Laser Light. Do not stare into beam class 2 laser product 630 – 680 nm, 1 mW.
  • Do not modify the device structurally.
  • Do not expose the device to high temperatures.
  • Do not expose the device to strong UV radiation.
  • Do not expose the device to processes with high electrical charges.
  • Do not expose the device to aggressive acids or bases.
  • When working in explosion hazardous areas, please note:
  • Do not loosen the screws on the device.
  • Do not open any interface cover.
  • Do not charge the IS530.2.
  • Do not open the device.
  • Do not damage the device.

SCOPE OF DELIVERY
Your device packaging contains the following:

  • 1 x IS-TH1xx.2
  • 1 x Operating Manual Safety Instructions
  • 1 x Screwdriver
  • 1 x Lanyard IS-TH

INSTALLATION

DANGER
Improper use can result in death or severe injuries! Only connect the device outside explosion hazardous areas to the ISM interface of the IS530.2.i safe
MOBILE IS-TH1xx.2 Barcode Scanner Trigger Handle - fig 1

  • Unscrew the cover of the ISM interface (1) located on the IS530.2.
  • Push the IS530.2 completely into the holder (2) of the device.
  • Unscrew the screw (3).
  • Loosen the plug (4).
  • Attach the plug on top of the ISM interface (5).
  • Fix the plug by pressing the rounded end of the plug (6).
  • Tighten the screw (7).
  • Check whether the plug is correctly and firmly attached to the ISM interface.

The device can now be used together with the IS530.2 in explosion hazardous areas.
POSSIBLE DEVICE PROBLEMS
You can find information on possible device problems and how to rectify them at www.isafe-mobile.com/en/support/service under the menu item “FAQ”.

If you have any further questions, please contact the i.safe MOBILE repair service at www.isafe-mobile.com/en/support/service

MAINTENANCE/REPAIR

The device itself has no serviceable parts.
WARNING
Incorrect repairs present a risk of explosion or fire, which can result in death or severe injuries! Do not open the device or carry out any repairs yourself.
Contact the i.safe MOBILE repair service at www.isafe- mobile.com/en/support/service if the device is not working normally, if the device needs to be repaired or if a replacement part is required.
RETURN SHIPMENT
Contact the i.safe MOBILE repair service at www.isafe- mobile.com/en/support/service
DISTRIBUTION PARTNER
You can find the specialist distribution partner responsible for your country at www.isafe-mobile.com/en/contact
CLEANING
NOTICE
Incorrect cleaning can cause damage to the device. Please note the following when cleaning:

  • Do not use chemical agents for cleaning.
  • Clean the device with a soft, moistened antistatic cloth.

STORAGE
NOTICE
Incorrect storage can cause damage to the device. Store the device at ambient temperatures between +5 °C to +35 °C (41 °F to +95 °F) and a humidity between 10 % to 60 %.
RECYCLING
NOTICE
Incorrect disposal of electronic products, batteries and packaging material puts the environment at risk. Please note the following when disposing of items:

  • DO NOT throw away batteries with household waste.
  • Always dispose electronic products, batteries and packaging material at the appropriate collection points.
    This way, you prevent uncontrolled waste disposal and promote the recycling of material resources.

 You can obtain further information from regional waste disposal companies, state authorities or the i.safe MOBILE service centre responsible for your country or  region at www.isafe-mobile.com/en/support/service
TRADEMARKS
i.safe MOBILE and the i.safe MOBILE logo are registered trademarks of the i.safe MOBILE GmbH. All other trademarks and copyrights are the properties of their respective owners.
EU/UK DECLARATION OF CONFORMITY
according to directive 2014/34/EU, SI 2016 No. 1107, 2014/30/EU, SI 2016 No. 1091, 2014/35/EU, SI 2016 No. 1101, 2011/65/EU (2015/863/EU), SI 2012 No. 3032
The company i.safe MOBILE GmbH declares under its sole responsibility that the product to which this declaration relates is in accordance with the provisions of the following data, directives and standards:

Name & address of the manufacturer in the EU| i.safe MOBILE GmbH
i_Park Tauberfranken 10
97922 Lauda – Koenigshofen
Germany
---|---
Description of the device| Trigger Handle
type: IS-TH1MR.2 and IS-TH1ER.2
model : MTHA10 and MTHA11
Ex – marking| II 3G Ex ic op is IIC T4 Gc
II 3D Ex ic op is IIIC T135°C Dc
Conformity statement 2014/34/EU issued by| EPS 21 ATEX 1 082 X Bureau Veritas
Consumer Products Services Germany GmbH Oehleckerring 40
22419 Hamburg, Germany identification number : 2004
EN IEC 60079-0:2018; EN 60079-11:2012;
EN 60079-28:2015
Applied harmonized standards
Conformity statement SI 2016 No. 1107 issuedby| CML 21UKEX21327X
Eurofins E&E CML Limited,
Newport Business Park, New Port Road, Ellesmere Port,
CH65 4LZ, United Kingdom identification number 2503
EN IEC 60079-0:2018; EN 60079-11:2012;
EN 60079-28:2015
Applied standards

EU/UK DECLARATION OF CONFORMITY

Conformity statement 2014/35/EU issued by
Applied harmonized standards| Shenzhen TCT Testing Technology Co., Ltd. 1B/F., Building 1, Yibaolai Industrial Park. Qiaotou, Fuyong, Baoan District,
Shenzhen, Guangdong, China
EN 62368-1:2014+A11:2017
---|---
Conformity statement SI 2016 No. 1101 issued by
Applied harmonized standards| Shenzhen TCT Testing Technology Co., Ltd. 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District,
Shenzhen, Guangdong, China
BS EN 62368-1:2014+A11:2017
Conformity statement 2014/30/EU issued by
Applied harmonized standards| Shenzhen TCT Testing Technology Co., Ltd. 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District,
Shenzhen, Guangdong, China
EN 55032:2015; EN 55035:2017
Conformity statement SI 2016 No. 1091 issued by
Applied harmonized standards| Shenzhen TCT Testing Technology Co., Ltd. 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District,
Shenzhen, Guangdong, China
BS EN 55032:2015; BS EN 55035:2017
Conformity statement 2015/863/EU amending 2011/65/EU issued by
Applied harmonized standards| Shenzhen TCT Testing Technology Co., Ltd. 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District,
Shenzhen, Guangdong, China
IEC 62321-2:2013; IEC 62321-3-1:2013; IEC 62321-5:2013;
IEC 62321-4:2013+AMD1:2017;
IEC 62321-7-1:2015; IEC 62321-7-2:2017; IEC 62321-6:2015; IEC 62321-8:2017
Conformity statement SI 2012 No. 3032 issued by
Applied harmonized standards| Shenzhen TCT Testing Technology Co., Ltd. 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District,
Shenzhen, Guangdong, China
BS EN 62321-2:2014; BS EN 62321-3-1:2014;
BS EN 62321-5:2014;
BS EN 62321-4:2014+AMD1:2017;
BS EN 62321-7-1:2015; BS EN 62321-7-2:2017; BS EN 62321-6:2015; BS EN 62321-8:2017
CE/UKCA Marking| ****
---|---

Lauda – Koenigshofen 27.10.2022i safe MOBILE IS-TH1xx.2 Barcode Scanner
Trigger Handle - fig 2 CONTACT/SERVICE CENTRE
FOR FURTHER QUESTIONS PLEASE CONTACT OUR SERVICE CENTRE:
i.safe MOBILE GmbH, i_Park Tauberfranken 10, 97922 Lauda-Koenigshofen, Germany
support@isafe-mobile.com
https://support.isafe-mobile.com
WWW.ISAFE-MOBILE.COM

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

i safe MOBILE User Manuals

Related Manuals