i safe MOBILE IS330.1 Cell Phone Instruction Manual
- June 8, 2024
- i safe MOBILE
Table of Contents
Cell Phone Instruction Manual
IS330.1
MODEL M33A01
IS330.1 Cell Phone
EX MARKINGS
ATEX:
II 2G Ex ib IIC T4 Gb
II 2D Ex ib IIIC T135°C Db IP6X
EU Type Examination Certificate:
EPS 19 ATEX 1 073 X
CE-designation: ****2004
IECEx:
Ex ib IIC T4 Gb
Ex ib IIIC T135°C Db IP6X
IECEx Certificate: IECEx EPS 19 .0036X
UKEX:
II 2G Ex ib IIC T4 Gb
II 2D Ex ib IIIC T135°C Db IP6X
CML 21UKEX2492X
UKCA-designation: **** 2503
North America:
Class I Div 1 Groups A, B, C, D, T4
Class II Div 1 Groups E, F, G , T135˚C
Class III Div 1
CSA20CA70220247
Temperature range:
-20°C … +60°C (EN/IEC 60079-0)
-10°C … +50°C (EN/IEC 62368-1)
Manufactured by:
i.safe MOBILE GmbH
i_Park Tauberfranken 10
97922 Lauda-Koenigshofen Germany
EX-RELEVANT SAFETY REGULATIONS
Use of this device assumes that the operator observes the conventional safety
regulations and has read and understood manual, safety instructions and
certificate .
The following safety regulations must also be complied with:
- Inside ex-hazardous areas the covers of all interfaces must be closed . To ensure the IP64-protection, it has to be ensured that all gaskets are present and functional . There must be no large gap between the two halves of the housing .
- The device may only be charged outside ex-hazardous areas using the i.safe PROTECTOR 2.0
- USB (type C)-cable or other equipment approved by i.safe MOBILE GmbH .
- The USB interface (type C) can be used for data transmission in non-hazardous areas . It is not permitted to open the USB interface cover in hazardous locations .
- The ISM interface of the device can be used within hazardous areas with approved headsets,
- Remote Speaker Microphones (RSM) and add-ons .
- For the ISM interface-connection the intrinsically safe approved accessories must comply with entity parameters according to document 1029AD04 – i .e . Headset IS-HS1.1 is approved to be used on ISM interface .
- If the ISM interface is not used, it must be securely closed by the cover provided for this purpose .
- The device may only be charged at ambient temperatures between +5°C . . . +35°C .
- The device may not be exposed to any aggressive acids or alkalis .
- The device may only be used in zones 1, 2, 21, or 22 .
EX-RELEVANT SAFETY REGULATIONS FOR NORTH AMERICA
Conditions of Acceptability:
- The battery may be charged outside explosion hazardous areas only using approved external adapter model ICP12-050-2000B with output rated 5Vdc, 2A or other external approved AC/
- DC adapter which also complies with the requirements of LPS and has output rated 5Vdc, 2A .
- The battery may be replaced with an identical one outside of the explosion hazardous areas only .
- To ensure the IP64 protection, it has to be ensured that all gaskets are present and functional .
- There must be no gap between the two halves of housing and between the battery cover and housing .
- The USB interface (type C) located at the left side is for data transmission and it is used in non hazardous areas . It is not permitted to open the USB interface cover in hazardous locations .
- The ISM interface of the device located at the right side can be used within hazardous areas with approved headsets, Remote Speaker Microphones(RSM) and add-ons .
- For the ISM interface-connection the intrinsically safe approved accessories must comply with entity parameters according to document 1029AD04 i .e . Headset IS-HS1.1 is approved to be used on ISM interface . If the ISM interface is not used, it must be securely closed by the cover provided for this purpose .
- The device must be protected against excessive UV light emission and high electrostatic processes .
- The device may only be charged at temperatures between +5°C . . . +35°C .
INFORMATION CONCERNING SAR CERTIFICATION
(SPECIFIC ABSORBATION RATE)
Maximum SAR values for this model and the conditions under which these were determined:
SAR (head) | 0 .62 W/kg |
---|---|
SAR (body – worn) | 0 .93 W/kg |
This device was tested for typical body-worn operations with the back of the handset kept 5 mm from the body .
NB WARNING
CAUTION
- Use careful with the earphone maybe possible excessive sound pressure from earphones and headphones can cause hearing loss .
- CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE . DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS .
- Operation temperature: -20°C …+60°C (EN/IEC 60079-0)/ -10°C …+50°C (EN/IEC 62368-1) .
- The device shall only be connected via the i.safe PROTECTOR 2.0 USB cable or another accessory authorised by i.safe MOBILE GmbH .
AC Adapter:
-
Approved external adapter model ICP12-050-2000B (Input: AC100-240V 50/60Hz 0 .3A;
Output: 5VDC, 2A) or other approved external AC/DC adapter which complies with the requirements of LPS (Limited Power Source) and has output rated 5VDC/2A. -
Adapter shall be installed near the equipment and shall be easily accessible .
-
The plug is considered independent of the adapter .
The device complies with RF specifications when the device used at 0 .5 cm from your body .
The i.safe MOBILE GmbH hereby declares that this smart phone is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU . This information has to be presented in such a way that the user can readily understand it . Typically, this will necessitate translation into every local language (required by national consumer laws) of the markets where the equipment is intended to be sold . Illustrations, pictograms and using international abbreviations for country names may help reduce the need for translation .
Restrictions in the 5 GHz band:
According to Article 10 (10) of Directive 2014/53/EU, the packaging shows that
this radio equipment will be subject to some restrictions when placed on the
market in Belgium (BE),Bulgaria (BG), the Czech Republic (CZ),Denmark (DK),
Germany (DE), Estonia (EE), Ireland (IE), Greece (EL), Spain(ES), France (FR),
Croatia (HR), Italy (IT), Cyprus (CY), Latvia (LV), Lithuania(LT), Luxembourg
(LU), Hungary (HU), Malta (MT), Netherlands (NL), Austria (AT), Poland (PL),
Portugal (PT), Romania (RO), Slovenia (SI), Slovakia (SK),Finland (FI),
Sweden (SE), the United Kingdom (UK), Turkey (TR), Norway(NO), Switzerland
(CH), Iceland (IS), and Liechtenstein (LI) .The WLAN function for this device
is restricted to indoor use only when operating in the 5150 to 5350 MHz
frequency range .
| AT| BE| BG| CH| CY| CZ| DE| DK
---|---|---|---|---|---|---|---|---
EE| EL| ES| Fl| FR| HR| HU| IE
IS| IT| LI| LT| LU| LV| MT| NL
PL| PT| RO| SE| SI| SK| TR| UK
EU/UK-DECLARATION OF CONFORMITY
according to directive 2014/34/EU, SI 2016 No. 1107, 2014/53/EU, SI 2017 No.
1206, 2011/65/EU (2015/863/EU), SI 2012 No. 3032
The company i.safe MOBILE GmbH declares under its sole responsibility that the
product to which this declaration relates is in accordance with the provisions
of the following data, directives and standards:
Name & address of the manufacturer in the EU| i.safe MOBILE GmbH
i_Park Tauberfranken 10
97922 Lauda – Koenigshofen
Germany
---|---
Description of the devices| Explosion protected mobile phone
type / : IS330.1 & IS-HS1.1
model / : M33A01
Ex – marking| II 2G Ex ib IIC T4 Gb
II 2D Ex ib IIIC T135°C Db IP6X
Type examination certificate 2014/34/EU
issued by Applied harmonized standards| EPS 19 ATEX 1 073 X
Bureau Veritas Consumer Products Services
Germany GmbH
Oehleckerring 40
22419 Hamburg, Germany
identification number / : 2004 EN IEC 60079-0:2018;
EN 60079-11:2012
Type examination certificate SI 2016 No. 1107 issued by
Applied standards| CML 21UKEX2492X
Erofins E&E CML Limited,
Newport Business Park, New Port Road,
Ellesmere Port,
CH65 4LZ, United Kingdom identification number /: 2503
EN IEC 60079-0:2018; EN60079-11:2012
EU/UK-DECLARATION OF CONFORMITY
Conformity statement 2014/53/EU issued by Applied harmonized standards|
Notified Body
PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg
Germany
identification number : 0700
EN 62368-1:2014+A11:2017;
EN 50332-1:2013; EN 50360:2017;
EN 50566:2017; EN 62209-1:2016;
EN 62209-2:2010+A1:2019;
EN 62479:2010; EN 50663:2017;
EN IEC 62311:2020;
ETSI EN 301 489-1 V2.2.3;
ETSI EN 301 489-3 V2.1.1;
ETSI EN 301 489-17 V3.2.4;
ETSI EN 301 489-19 V2.1.1;
Draft ETSI EN 301 489-52 V1.1.0;
EN 55032:2015+A11:2020;
EN 55035:2017+A11:2020;
ETSI EN 301 511 V12.5.1;
ETSI EN 301 908-1 V13.1.1;
ETSI EN 301 908-2 V13.1.1;
ETSI EN 300 328 V2.2.2;
ETSI EN 301 893 V2.1.1;
ETSI EN 300 440 V2.2.1;
ETSI EN 300 330 V2.1.1;
ETSI EN 303 413 V1.1.1
---|---
Conformity statement SI 2017 No. 1206 issued
by Applied standards| MiCOM Labs Inc.
575 Boulder Court,
Pleasanton, California 94566
USA
identification number : 2280
EN IEC 62368-1:2014+A11:2017;
EN 62209-1:2016;
EN 62209-2:2010/A1:2019
EN 50360:2017; EN 50566:2017;
EN 50663:2017; EN 50332-1:2013;
EN 50332-2:2013; EN IEC 62311:2020;
EN 62479:2010; Draft EN 301 489-52 V1.1.0;
EN 301 489-19 V2.1.1; EN 301 489-17 V3.2.4;
EN 301 489-3 V2.1.1; EN 301 489-1 V2.2.3;
EN 55032:2015+A11:2020;
EN 55035:2017+A11:2020;
EN 300 328 V2.2.2;
EN 301 893 V2.1.1; EN 300 440 V2.2.1;
EN 303 413 V1.2.1; EN 301 511 V12.5.1;
EN 301 908-1 V13.1.1; EN 301 908-2 V13.1.1;
EN 301 908-13 V13.1.1; EN 300 330 V2.1.1;
Conformity statement 2015/863/EU amending
2011/65/EU issued by Applied harmonized standards| SGS-CsTC Standards
Technical Services Co.,
Ltd.
198 Kezhu Road,
Scientech Park Guangzhou Economic &
Technology Development District,
Guangzhou, China 510663
IEC 62321-2: 2013; IEC 62321-1: 2013;
IEC 62321-3-1: 2013; IEC 62321-5: 2013;
IEC 62321-4: 2013 + A1: 2017;
IEC 62321-7-1: 2015;
IEC 62321-7-2: 2017 & ISO 17075-1: 2017;
IEC 62321-6: 2015;
IEC 62321-8: 2017
Conformity statement SI 2012 No. 3032 issued by Applied standards| SGS-CsTC
Standards Technical Services Co.,
Ltd.
198 Kezhu Road,
Scientech Park Guangzhou Economic &
Technology Development District,
Guangzhou, China 510663
IEC 62321-2: 2021; IEC 62321-1: 2013;
IEC 62321-3: 2013; IEC 62321-5: 2013;
IEC 62321-4: 2013 + A1: 2017;
IEC 62321-7-1: 2015; IEC 62321-7-2: 2017;
IEC 62321-6: 2015; IEC 62321-8: 2017;
ISO 17075-1:2017
CE/UKCA Marking|
Document No . 1027MM11REV02
Version: 2022-10-31
(c) 2022 i.safe MOBILE GmbH
i .safe MOBILE GmbH
i_Park Tauberfranken 10
97922 Lauda-Koenigshofen
Germany
Tel . +49 9343 60148-0
info@isafe-mobile.com
www.isafe-mobile.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>