i safe MOBILE MTHA10, MTHA11 Multifunctional Set Instruction Manual
- June 8, 2024
- i safe MOBILE
Table of Contents
i safe MOBILE MTHA10, MTHA11 Multifunctional Set
This Operating Manual complies with these standards : IEC 60079, IEC
82079, ANSI Z535.6
Diese Bedienungsanleitung erfüllt die Anforderungen der folgenden Normen
: IEC 60079, IEC 82079, ANSI Z535.
READ AND UNDERSTAND THE INSTRUCTIONS
- ROTECT YOUR LIFE AND READ THE OPERATING MANUAL
- This Operating Manual is part of the device IS-TH1xx.1 (model MTHA10 / MTHA11). This
- Operating Manual provides important information for safe use of the device.
- Before using the device, read this Operating Manual carefully and pay particular attention to the “Safety” section and the warnings highlighted with the warning symbol.
- Make sure you have access to this Operating Manual when you need it. You can find the current Operating Manual at www.isafe-mobile.com/en/support/downloads
- Follow all instructions given on the device and on the packaging. Follow local safety regulations.
INTENDED USE
- The device IS-TH1xx.1 is used for scanning barcodes. The device IS-TH1xx.1 is suitable for use in potentially explosive atmospheres classified zone 1/21 and 2/22 in accordance with directives 2014/34/EU, SI 2016 No. 1107 and 1999/92/EC, as well as the IECEx scheme.
- Only use the device as described in this Operating Manual. Any other use is considered improper and can lead to death, severe injuries and damage to the device.
- The manufacturer i.safe MOBILE GmbH does not assume any liability for damage caused by improper use. The warranty expires in the event of improper use.
WARRANTY
You can find the warranty conditions at www.isafe- mobile.com/en/support/service
EX MARKINGS ATEX:
- II 2G Ex ib op is IIC T4 Gb
- II 2D Ex ib op is IIIC T135°C Db
- EU Type Examination Certificate:
- EPS 20 ATEX 1 203 X
CE-designation: 2004
IECEx:
- Ex ib op is IIC T4 Gb
- Ex ib op is IIIC T135°C Db
- IECEx Certificate: IECEx EPS 20.0075X
UKEX:
- II 2G Ex ib op is IIC T4 Gb
- II 2D Ex ib op is IIIC T135°C Db
- UK Type Examination Certificate:
- CML 21UKEX21326X
- UKCA-designation: 2503
North America:
- Class I Div 1 Groups A, B, C, D, T4
- Class II Div 1 Groups E, F, G , T135˚C
- Class III Div 1
- CSA21CA80083774X
Temperature range:
- -20°C … +60°C (EN/IEC 60079-0)
- -10°C … +50°C (EN/IEC 62368-1)
Manufactured by:
- i.safe MOBILE GmbH
- i_Park Tauberfranken 10
- 97922 Lauda-Koenigshofen Germany
EU/UK DECLARATION OF CONFORMITY
You will find the EU/UK declaration of conformity at the end of this Operating Manual or at www.isafe-mobile.com/en/support/downloads
PRODUCT COMPLIANCE FOR NORTH AMERICA
Conforms to:
STD UL 62368-1, STD UL 913
Certified to:
CSA STD CSA C22.2#60079-0, CSA STD CSA C22.2#60079-11, CSA STD CSA
C22.2#62368-1
DEVICE OVERVIEW
- HOLDER: Holder for IS530.1
- PLUG: Connecting IS530.1
- SCAN BUTTON: Scanning barcodes
- EYELET: Eyelet for Lanyard IS-TH
NAME CONCEPT
The two “xx” in IS-TH1xx.1 are placeholders. The IS-TH1xx.1 comes in two variants with different scan ranges and scan engines:
SAFETY
Read the “Safety” section of this Operating Manual carefully before using the
device. If you
do not follow these instructions or do not understand them, this could lead to
death, severe
injuries and damage to the device.
USER
Only trained users who are qualified in the use of Ex devices in explosion
hazardous areas andv who have read and understood this Operating Manual may
use this device.
EX-RELEVANT SAFETY REGULATIONS
- Use of this device assumes that the operator observes the conventional safety regulations and has read and understood Operating Manual, Safety Instructions and certificate. When used in explosion hazardous areas, the following Safety Instructions must also be complied with:
- The device may be connected only outside ex-hazardous areas to the IS530.1 via the ISM interface.
- To ensure the IP-protection, it has to be ensured that all gaskets are present and functional. There must be no large gap between the two halves of the housing.
- The device must be securely fastened to the ISM interface when used in ex-hazardous areas.
- The device may not be exposed to any aggressive acids or alkalis.
- The device may only be used in zones 1, 2, 21, or 22.
- Only accessories approved by i.safe MOBILE GmbH may be used.
EX-RELEVANT SAFETY REGULATIONS FOR NORTH AMERICA
Conditions of Acceptability:
The Barcode Scanner IS-TH1xx.1 must be protected from impacts with high impact
energy, against excessive UV light emission and high electrostatic charge
processes.
The 13-Pin connector of the IS-TH1xx.1 may only be assembled or disassembled
from the ISM
interface outside hazardous areas.
The 2 pin charging contacts of the IS-TH1xx.1 should only be used in non-
hazardous locations.
Unauthorized repair is not allowed. Apparatus is for use in pollution degree 2
or better. Only designated charger may be connected to the charging contacts.
Not suitable for hazardous locations when enclosure is damaged.
USE IN EXPLOSION HAZARDOUS AREAS
Improper use can result in death or severe injuries!
Only use the device in explosion hazardous areas of zones 1/21 and 2/22 or
outside of explosion hazardous areas.
Only connect the device outside explosion hazardous areas to the ISM interface
of the IS530.1.
Before entering an explosion hazardous area with the device,
make sure that the device is securely fastened to the ISM interface of the
IS530.1
make sure that no gap can be seen between the two halves of the device,
make sure the device is not damaged,
make sure that all the labels on the device are readable.
If you use the device in an explosion hazardous area, read and follow the
instructions in the “Possible User Errors” section.
Switch off the device immediately and leave the explosion hazardous area
without delay if malfunctions occur on the device, you have damaged the
housing of the device, you have exposed the device to excessive loads, the
labels on the device are no longer readabl
POSSIBLE USER ERRORS
DANGER
- Improper use can result in death or severe injuries! Follow the instructions below:
- Laser Light. Do not stare into beam class 2 laser product 630 – 680 nm, 1 mW.
- Do not modify the device structurally.
- Do not expose the device to high temperatures.
- Do not expose the device to strong UV radiation.
- Do not expose the device to processes with high electrical charges.
- Do not expose the device to aggressive acids or bases.
When working in explosion hazardous areas, please note:
- Do not loosen the screws on the device.
- Do not open any interface cover.
- Do not charge the IS530.1.
- Do not open the device.
- Do not damage the device.
SCOPE OF DELIVERY
Your device packaging contains the following:
- IS-TH1xx.1
- x Operating Manual Safety Instructions
- x Screwdriver
- 1 x Lanyard IS-TH
INSTALLATION
DANGER
Improper use can result in death or severe injuries! Only connect the device
outside explosion hazardous areas to the ISM interface of the
IS530.1
- Unscrew the cover of the ISM interface (1) located on the IS530.1.
- Push the IS530.1 completely into the holder (2) of the device.
- Unscrew the screw (3).
- Loosen the plug (4).
- Attach the plug on top of the ISM interface (5).
- Fix the plug by pressing the rounded end of the plug (6).
- Tighten the screw (7).
- Check whether the plug is correctly and firmly attached to the ISM interface.
- The device can now be used together with the IS530.1 in explosion hazardous areas
POSSIBLE DEVICE PROBLEMS
You can find information on possible device problems and how to rectify them
at
www.isafe-mobile.com/en/support/service under the menu item “FAQ”.
If you have any further questions, please contact the i.safe MOBILE repair
service at
www.isafe-mobile.com/en/support/service
MAINTENANCE/REPAIR
The device itself has no serviceable parts.
WARNING
Incorrect repairs present a risk of explosion or fire, which can result in death or severe injuries! Do not open the device or carry out any repairs yourself. Contact the i.safe MOBILE repair service at www.isafe- mobile.com/en/support/service if the device is not working normally, if the device needs to be repaired or if a replacement part is required.
RETURN SHIPMENT
Contact the i.safe MOBILE repair service at www.isafe- mobile.com/en/support/service
DISTRIBUTION PARTNER
You can find the specialist distribution partner responsible for your country at www.isafe-mobile.com/en/contact
NOTICE
- Incorrect cleaning can cause damage to the device. Please note the following when cleaning:
- Do not use chemical agents for cleaning.
- Clean the device with a soft, moistened antistatic cloth.
STORAGE
NOTICE
Incorrect storage can cause damage to the device. Store the device at ambient
temperatures between +5 °C to +35 °C (41 °F to +95 °F) and a humidity between
10 % to 60 %.
RECYCLING
NOTICE
Incorrect disposal of electronic products, batteries and packaging material
puts the environment at risk. Please note the following when disposing of
items:
DO NOT throw away batteries with household waste. Always dispose electronic
products, batteries and packaging material at the appropriate collection
points. This way, you prevent uncontrolled waste disposal and promote the
recycling of material resources.
You can obtain further information from regional waste disposal companies,
state authorities or the i.safe MOBILE service centre responsible for your
country or region at
www.isafe-mobile.com/en/support/service
TRADEMARKS
i.safe MOBILE and the i.safe MOBILE logo are registered trademarks of the
i.safe MOBILE GmbH. All other trademarks and copyrights are the properties of
their respective owners.
CONTACT/SERVICE CENTRE
FOR FURTHER QUESTIONS PLEASE CONTACT OUR SERVICE CENTRE: i.safe MOBILE GmbH,
i_Park Tauberfranken 10, 97922 Lauda-Koenigshofen, Germany
support@isafe-mobile.com
https://support.isafe-mobile.com
EU/UK DECLARATION OF CONFORMITY
EU/UK – Declaration of Conformity EU/UK – Konformitätserklärung according to
directive 2014/34/EU, SI 2016 No. 1107, 2014/30/EU, SI 2016 No. 1091,
2014/35/EU, SI 2016 No. 1101, 2011/65/EU (2015/863/EU), SI 2012 No. 3032 nach
Richtlinie 2014/34/EU, SI 2016 No. 1107, 2014/30/EU, SI 2016 No. 1091,
2014/35/EU, SI 2016 No. 1101, 2011/65/EU (2015/863/EU), SI 2012 No. 3032
The company i.safe MOBILE GmbH declares under its sole responsibility that the
product to which this declaration relates is in accordance with the provisions
of the following data, directives and standards:
Name & address of the manufacturer in the EU | i.safe MOBILE GmbH |
---|---|
Name & Anschrift des Herstellers innerhalb der | i_Park Tauberfranken 10 |
europäischen Gemeinschaft | 97922 Lauda – Koenigshofen |
Germany |
Description of the device
Beschreibung der Geräte
| Trigger Handle
type / Typ : IS-TH1MR.1 and IS-TH1ER.1 model / Modell : MTHA10 and MTHA11
Ex – marking
Ex – Kennzeichnung
| II 2G Ex ib op is IIC T4 Gb
II 2D Ex ib op is IIIC T135°C Db
Type examination certificate 2014/34/EU issued by
Baumusterprüfbescheinigung 2014/34/EU ausgestellt durch
| EPS 20 ATEX 1 203 X
__
Bureau Veritas
Consumer Products Services Germany GmbH Oehleckerring 40
22419 Hamburg, Germany
identification number / Kenn-Nummer : 2004
Applied harmonized standards
Angewandte harmonisierte Standards
| EN IEC 60079-0:2018; EN 60079-11:2012;
EN 60079-28:2015
Type examination certificate SI 2016 No. 1107
issued by
Baumusterprüfbescheinigung SI 2016 No. 1107 ausgestellt durch
| CML 21UKEX21326X
__
Eurofins E&E CML Limited,
Newport Business Park, New Port Road, Ellesmere Port, CH65 4LZ, United Kingdom identification number / Kenn-Nummer : 2503
Applied standards
Angewandte Standards
| EN IEC 60079-0:2018; EN 60079-11:2012;
EN 60079-28:2015
Conformity statement 2014/35/EU issued by Konformitätsaussage 2014/35/EU ausgestellt durch
Applied harmonized standards
Angewandte harmonisierte Standards
| Shenzhen TCT Testing Technology Co., Ltd. 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District, Shenzhen, Guangdong, China
EN 62368-1:2014+A11:2017
---|---
Conformity statement SI 2016 No. 1101 issued by
Konformitätsaussage SI 2016 No. 1101 ausgestellt durch
Applied harmonized standards
Angewandte harmonisierte Standards
| Shenzhen TCT Testing Technology Co., Ltd. 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District, Shenzhen, Guangdong, China
BS EN 62368-1:2014+A11:2017
Conformity statement 2014/30/EU issued by Konformitätsaussage 2014/30/EU ausgestellt durch
Applied harmonized standards
Angewandte harmonisierte Standards
| Shenzhen TCT Testing Technology Co., Ltd. 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District, Shenzhen, Guangdong, China
EN 55032:2015;
EN 55035:2017
Conformity statement SI 2016 No. 1091 issued by
Konformitätsaussage SI 2016 No. 1091 ausgestellt durch
Applied harmonized standards
Angewandte harmonisierte Standards
| Shenzhen TCT Testing Technology Co., Ltd. 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District, Shenzhen, Guangdong, China
BS EN 55032:2015;
BS EN 55035:2017
Conformity statement 2015/863/EU amending 2011/65/EU issued by
Konformitätsaussage 2015/863/EU ergänzt 2011/65/EU ausgestellt durch
Applied harmonized standards
Angewandte harmonisierte Standards
| Shenzhen TCT Testing Technology Co., Ltd. 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District, Shenzhen, Guangdong, China
IEC 62321-2:2013; IEC 62321-3-1:2013;
IEC 62321-5:2013;
IEC 62321-4:2013+AMD1:2017;
IEC 62321-7-1:2015; IEC 62321-7-2:2017;
IEC 62321-6:2015; IEC 62321-8:2017
Conformity statement SI 2012 No. 3032 issued by
Konformitätsaussage SI 2012 No. 3032 ausgestellt durch
Applied harmonized standards
Angewandte harmonisierte Standards
| Shenzhen TCT Testing Technology Co., Ltd. 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District, Shenzhen, Guangdong, China
BS EN 62321-2:2014; BS EN 62321-3-1:2014;
BS EN 62321-5:2014;
BS EN 62321-4:2014+AMD1:2017; BS EN 62321-7-1:2015;
BS EN 62321-7-2:2017;
BS EN 62321-6:2015; BS EN 62321-8:2017
CE/UKCA Marking
CE/UKCA-Kennzeichnung
| CE2004
2503
---|---
WWW.ISAFE-MOBILE.COM
Document No. 1040MM01REV06 Version: 2022-10-27 (c) 2022 i.safe MOBILE GmbH
i.safe MOBILE GmbH i_Park Tauberfranken 10 97922 Lauda-Koenigshofen Germany
Tel. +49 9343 60148-0
info@isafe-mobile.com
www.isafe-mobile.com
References
- Zertifizierte Smartphones, Tablets und Mobiltelefone für IECEx und ATEX Zonen
- Wir beraten Sie weltweit
- Betriebsanleitungen, Produktflyer, Datenblätter uvm.
- Service & Support
- We advise you worldwide
- Datasheets, Manuals, Certificates and Product Folders
- Our service team will be happy to assist you
- I.SAFE MOBILE À L'ÉCHELLE MONDIALE
- Service chez
- Support - Official i.safe MOBILE Support
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>