FLASH F7100566 4x LED Moving Head Light User Manual
- June 9, 2024
- FLASH
Table of Contents
F7100566 4x LED Moving Head Light
User Manual
F7100566 4x LED Moving Head Light
(EN) THANK YOU FOR PURCHASING THIS FLASH-BUTRYM PRODUCT. BEFORE BEGINNING TO OPERATE THIS UNIT, PLEASE READ THE INSTRUCTIONS CAREFULLY TO ENSURE THE BEST POSSIBLE PERFORMANCE.
INTRODUCTION
THANK YOU FOR PURCHASING 36X10W RGBW 4IN1 ZOOM 3 SECTIONS VER.0922. FOR SAFETY REASONS AND TO ENSURE THE TROUBLE-FREE OPERATION, CAREFULLY READ THE INSTRUCTIONS.
SAFETY INFORMATION
- Please keep this User Manual for future consultation. If you sell the fixture to another user, be sure that they also receive this instruction booklet.
- Unpack and check carefully there is no transportation damage before using the fixture.
- Before operating, ensure that the voltage and frequency of power supply match the power requirements of the fixture.
- It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
- Disconnect main power before servicing and aintenance.
- Use safety chain when fixes this fixture. Don’t handle the fixture by taking its head only, but always by taking its base.
- Maximum ambient temperature is: 40°C Don’t operate it where the temperature is higher than this.
- In the event of serious operating problem, stop using the fixture immediately. Never try to repair the fixture by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
- Do not connect the device to any dimmer pack.
- Do not touch any wire during operation and there might be a hazard of electric shock.
- To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain or moisture.
- The housing must be replaced if they are visibly damaged.
- Do not look directly at the LED light spot while the fixture is on.
WARNING
WARNING! The Led Moving Head (LMH) has a powerful pan motor. The torque
reaction when the head is panned suddenly can cause the base to move if the
fixture is standing unsecured on a surface. Do not apply power to the LMH
unless the baase is securely fastened to a surface or to rigging hardware.
WARNING! Use 2 clamps to rig the fixture. Do not hang the fixture from
only one clamp. Lock each clamp with both 1/4-turn fasteners. Fasteners are
locked only when turned a full 900 clockwise.
WARNING! When clamping the fixture to a truss or other structure at any
other angle than with the yoke hanging vertically downwards, use two clamps of
half-coupler type. Do not use any type of clamp that does not completely
encircle the structure when fastened.
WARNING! Position or shade the head so that the front lens will not be
exposed to sunlight or any other strong light source from any angle – even for
a few seconds. See Figure 1. The LMH lens can focused the sun’s rays, creating
a potential fire hazard and causing damage.
IMPORTANT! Do not point strong light output from other fixtures at the
LMH, as intense illumination can damaged the display. Figure 1. Lenses can
focused sunlight and strong light, presenting a risk of fire and damage to the
fixture. Shield or shade the head if necessary.
PRODUCT INFORMATION
Power consumption: 360W | Number of DMX channels: 16/24 |
---|---|
Power supply voltage: 110 – 230V | DMX standard: DMX 512 |
Voltage frequency: 50/60Hz | Control interface: 4 buttons |
Diode type: 4in1 | AC IN: powerCON |
Number of diodes: 36 | AC OUT: powerCON |
Diode power: 10W | DMX IN: XLR – 3 pin |
Display: Color LCD | DMX OUT: XLR – 3 pin |
Color: RGBW | IP Rating: IP20 |
ZOOM: YES | Housing made: ABS |
Dimming: Linear: 0 – 100% | Cooling: Active |
Flash frequency (min): 0Hz | Net Weight: 8,8kg |
Flash frequency (max): 20Hz | Dimensions: H(44 )xW(33)xD(22) cm |
PAN range: 540° | Dim. (case): H(64/53,5/ )xW(55)xD(87) cm |
TILT range: 270° | Weight (case): 64,6kg |
INSTALLATION
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture. The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of people and has no one pass by or under it.
CONNECTION
The device is equipped with the following interfaces:
- DMX (in/out): XLR 3(5)-pin socket
- Power (in/out): powerCON socket
5.1 Connecting DMX signal
The connection is performed using cable with XLR-female -> XLR-Male plugs.
CAUTION! At the last fixture, the DMX signal has to be terminated with a
terminator. Solder a 120Ω resistor between signal (-) and signal (+) into a
XLR plug and plug it in the DMX output of the last fixture. 5.2 Voltage
specification
Input Voltage | Total Power | Frequency |
---|---|---|
100~230V AC | 210W | 50/60Hz |
5.3 Connecting power supply
The connection is performed using power cable with PowerCon connector
(included). The device must be operated by qualified personnel.
Make sure that the power grid supply parameters are consistent with device
parameters and limitations are not exceeded.
CAUTION! In the case of cable damage do not attempt to repair.
Replacement or repair can be made only on the manufacturer or by a person with
appropriate permissions.
Using lamp, the change rate of power voltage should be within ±10%, if the
voltage is too high, it will shorten the light’s life; if it’s not enough, the
lamp will be dark. Please restart it after turning off light for 20 minutes
until full-cooling. Frequent switching will reduce the life span of lamps and
bulbs; intermittent using will improve the life of bulbs and lamps.
5.4 Set DMX Address Code
The control panel is equipped with 4-digit display and 4 control buttons
with the following functions:
- MENU – choose function
- DOWN – change value
- UP – change value
- ENTER – confirm changes
DMX CHANNEL LIST
6.1 CH16 Mode
CH | Function | Value | Description |
---|---|---|---|
1 | Pan | 0-255 | 0-540° |
2 | Tih | 0-255 | 0-270° |
3 | Pan/Tilt speed | 0-255 | Fast – Slow |
4 | Dimmer | 0-255 | 0-100% |
5 | Red | 0-255 | 0-100% |
6 | Green | 0-255 | 0-100% |
7 | Blue | 0-255 | 0-100% |
8 | White | 0-255 | 0-100% |
9 | Strobe | 0-9 | Open |
10-255 | Strobe | ||
10 | Zoom | 0-255 | Wide – Narrow |
11 | Macro | 0-29 | Open |
30-39 | Macro 1 | ||
40-49 | Macro 2 | ||
50-59 | Macro 3 | ||
60-69 | Macro 4 | ||
70-79 | Macro 5 | ||
80-89 | Macro 6 | ||
90-139 | Macro 7 | ||
140-169 | Macro 8 | ||
170-199 | Macro 9 | ||
200-208 | Macro 10 | ||
209-228 | Macro 11 | ||
229-238 | Macro 12 | ||
239-255 | Macro 13 | ||
12 | Macro Rate | 0-255 | Slow – Fast |
13 | Pan fine | 0-255 | |
14 | lift fine | 0-255 | |
15 | Reset | 0-149 | Open |
150-255 | Reset | ||
16 | Empty |
6.2 CH24 Mode
CH | Funtion | Value | Description |
---|---|---|---|
1 | Pan | 0-255 | 0-5409 |
2 | TM | 0-255 | 0-2709 |
3 | PanfrItt speed | 0-255 | Fast – Slow |
4 | Dimmer | 0-255 | 0-100% |
5 | RI Red | 0-255 | 0-100% |
6 | RI Green | 0-255 | 0-100% |
7 | RI Blue | 0-255 | 0-100% |
8 | RI Mite | 0-255 | 0-100% |
9 | R2 Red | 0-255 | 0-100% |
10 | R2 Green | 0-255 | 0-100% |
11 | R2 Blue | 0-255 | 0-100% |
12 | R2 Mite | 0-255 | 0-100% |
13 | R3 Red 3 | 0-255 | 0-100% |
14 | R3 Green 3 | 0-255 | 0-100% |
15 | R3 Blue 3 | 0-255 | 0-100% |
16 | R3 Mite 3 | 0-255 | 0-100% |
17 | Strobe | 0-9 | Open |
10-255 | Strobe | ||
18 | Zoom | 0-255 | Wide-Narrow |
19 | Macro Colon | 0-29 | Open |
30-39 | Macro 1 | ||
40-49 | Macro 2 | ||
50-59 | Macro 3 | ||
60-69 | Macro 4 | ||
70-79 | Macro 5 | ||
80-89 | Macro 6 | ||
90-139 | Macro 7 | ||
140-169 | Macro 8 | ||
170-199 | Macro 9 | ||
200-208 | Macro 10 | ||
209. | Macro 11 | ||
229. | Macro 12 | ||
239. | Macro 13 | ||
20 | Macro Rate | 0-255 | Slow – Fast |
21 | Pan fine | 0-255 | |
22 | TM fine | 0-255 | |
23 | Reset | 0-149 | Open |
150-255 | Reset | ||
24 | Empty |
F7100566
www.flash-butrym.pl
Read User Manual Online (PDF format)