Laserliner 082 390 MultiWet-Master Compact Plus Material Moisture Meter Instruction Manual
- June 9, 2024
- Laserliner
Table of Contents
- 1 Insert battery
- 2 Room climate – measured values
- 3 Material moisture measurement Measuring mode selection
- 4 Capacitive measuring principle
- 5 Resistance measuring principle
- 6 Wet/dry LED indicator
- 7 Setting the wet/dry threshold values in index mode and Index Zoom mode
- 8 Temperature units of measure setting
- 9 Wood moisture/temperature compensation
- 10 AutoHold
- 11 LCD backlight
- 12 AUTO OFF function
- 13 Self-test function
- 14 Instruction for use – resistance measuring principle
- 15 Instruction for use – capacitive measuring principle
- 16 General instruction for use
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Laserliner 082 390 MultiWet-Master Compact Plus Material Moisture Meter Instruction Manual
! Completely read through the operating instructions, the ,,Warranty and Additional Information” booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and passed on together with the device.
Function / application
This material moisture measuring device operates in accordance with the
resistance and capacitive measuring principle. Material moisture is measured
by 2 conductive sensor pads on the underside of the device or by the
integrated measuring probes and calculated in % with internal material-
dependent characteristics. The displayed value shown in % refers to the dry
mass. Example: 1 kg of material containing 500 g of water = 100% relative
material moisture. The device is used to determine the moisture content in
wood and building materials with the aid of the corresponding measuring
method. An additional pop-out sensor on the side of the device determines the
ambient temperature and relative humidity and calculates the resulting dew
point temperature.
The integrated building materials characteristics correspond to the specified building materials and their designation. Building materials of the same type but with different designation / composition / strength / density can however affect the measurement result. Furthermore, ! building materials will vary from manufacturer to manufacturer due to the way they are produced. This is why, in the event of different product compositions or unfamiliar construction materials, a one-off comparative moisture measurement should be taken using methods that can be calibrated (e.g. kiln-drying method). If different measured values occur, they should either be viewed relatively or the index mode for moisture/drying behaviour should be used.
General safety instructions
-
The device must only be used in accordance with its intended purpose and within the scope of the specifications.
-
The measuring tools and accessories are not toys.
Keep out of reach of children. -
Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
-
Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
-
Do not use the measuring probe with an external voltage.
-
The device must no longer be used if one or more of its functions fail or the battery charge is weak.
Safety instructions Dealing with electromagnetic radiation
- The measuring device complies with electromagnetic compatibility regulations and limits in accordance with the EMC Directive 2014/30/EU which is covered by the Radio Equipment Directive 2014/53/EU.
- Local operating restrictions for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
- The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.
Safety instructions
Dealing with RF radiation
- The measuring device is equipped with a wireless interface.
- The measuring device complies with electromagnetic compatibility and wireless radiation regulations and limits in accordance with the RED 2014/53/EU.
- Umarex GmbH & Co. KG hereby declares that the Multi Wet-Master Compact Plus radio equipment complies with the essential requirements and other provisions of the European Radio Equipment Directive 2014/53/EU (RED). The EU Declaration of Conformity can be found in its entirety at the following address: http://laserliner.com/info?an=muwemacopl
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,
scouring agents and solvents. Remove the battery(ies) before storing for
longer periods. Store the device in a clean and dry place.
Calibration
The meter needs to be calibrated and tested on a regular basis to ensure it
produces accurate measurement results. We recommend carrying out calibration
once a year.
1 Insert battery
Open the battery compartment on the housing`s rear side and insert a 9V battery (6LR61 9V). Correct polarity must be observed.
-
Measuring probes, resistance measuring principle
-
Sensor pads capacitive measuring principle
-
Pop-out sensor for measuring ambient temperature and humidity
-
Battery compartment
-
LC display
-
Wet/dry LED indicator
-
Measuring mode selection (Resistance measuring principle, Capacitive measuring principle)
-
Material selection
-
ON/OFF
-
Bluetooth active
-
Ambient temperature in °C/°F
-
Relative humidity in %
-
Dew point temperature in °C/°F
-
Material indicator for wood Resistance measuring principle: A, B, C Capacitive measuring principle: softwood (S), hardwood (H)
-
Capacitive measuring principle
-
Battery charge
-
Material indicator for building materials
Resistance measuring principle: 1…8 -
Index mode / Index Zoom mode
-
Measured value in % of relative material moisture
-
Resistance measuring principle
2 Room climate – measured values
The measuring device features a fold-out sensor that measures the ambient temperature (A-Temp, 11) and relative humidity (RH, 12) while also calculating the dew point temperature (D-Temp, 13). By folding out the sensor, the improved through-flow of air speeds up the measurement procedure.
! When changing location and/or where there are large differences in the room climate, it is important to give the measuring device time to adapt until the measured values in the display have stabilized.
3 Material moisture measurement Measuring mode selection
The device features two different measuring modes. Resistance measurement uses the test prods whereas capacitive measurement uses the sensor pads on the underside of the device.
4 Capacitive measuring principle
4.1 Tables of materials
S (softwood) low-density woods: e.g. spruce, pine, limewood, poplar, cedar,
mahogany
H (hardwood) higher-density woods: e.g. beech, oak, ash, birch
4.2 Index mode
Index mode is used to rapidly locate moisture with comparative measurements, without a direct output of material moisture in %. The output value (0 through 1000) is an indexed value that increases as material moisture becomes greater. Measurements made in index mode are independent of material type and particularly useful with materials for which no characteristics are stored. When comparative measurements reveal strongly deviating values, the course of moisture in the material can be localized quickly.
Tip: Before using Index mode on hard building materials, first try out Index Zoom mode as this mode provides a higher resolution. Switch to Index mode when Index Zoom mode reaches the lower measuring range (measured value = 0).
4.3 Index Zoom mode
Index Zoom mode has been specially developed for hard building materials such as screed and concrete in order to track the drying progression of these materials. Index Zoom mode provides higher resolution in a specific measuring range.
5 Resistance measuring principle
5.1 Material characteristics
The material characteristics available for selection in the measuring device are listed in the tables below. The different types of wood are divided into Groups A … C. Please set the measuring device for the respective group in which the type of wood to be measured is found. A similar setting must also be made for measurements performed on building materials. Building materials are divided into groups 01 through 08. (refer Section 5)
5.2 Index mode (refer to Section 6.2)
In addition to the material characteristics stored in the measuring device, index mode makes it possible to measure other building materials (0931) using the resistance measurement method (see index mode conversion table). The displayed value (0 through 1000) serves as the basis.
Activate index mode in your measuring device (Section 5). In order to determine the degree of moisture in a type of building material, first find the material number for the building material to be measured. Following this, read the measured value from the scale displayed on the measuring device for index mode. Now determine the value for the corresponding material number in the table. If this value has a dark grey background, the material is to be classified as ,,wet”, values without coloured background are considered to be ,,dry”.
5.3 Index mode conversion tables
6 Wet/dry LED indicator
In addition to numeric measurement display in % of relative material moisture, the LED display also provides a material-dependent evaluation of moisture. The LED display bar becomes larger, from left to right, with increasing moisture content. The 12-position LED display is subdivided into 4 green (dry), 3 yellow (moist) and 5 red (wet) segments. Wet material causes an additional acoustic signal.
! The classification ,,dry” means that materials in a heated room have reached a balanced moisture level and are thus suitable for further processing.
7 Setting the wet/dry threshold values in index mode and Index Zoom mode
The wet/dry LED indicator is programmed in line with the relevant material characteristics so the LEDs also provide information about whether the material should be classified as dry, moist or wet. However the values in index mode and Index Zoom mode, which is independent of the material type, are output on a neutral scale whose value increases as the moisture level rises.
8 Temperature units of measure setting
The units of measure for ambient temperature and material compensation can be
set to either °C or °F. The setting is stored and remains in effect until it
is changed manually.
9 Wood moisture/temperature compensation
The relative material moisture of wood is dependent on temperature. The device
automatically compensates for different wood temperatures by measuring the
ambient temperature and using it for the internal calculation. To increase
measuring accuracy, however, the measuring device also offers an option for
setting the temperature manually. This value is not stored and must be set
again each time the device is switched on.
10 AutoHold
The AutoHold function is activated as standard and can be deactivated in the
menu. With AutoHold activated, as soon as the measured value is stable it is
automatically held on the display. This status is signalled acoustically. With
AutoHold deactivated, the measured value is continuously updated on the
display.
! Tip: The AutoHold function is suitable for measurements with no movement. Switch off the AutoHold function for scanning walls.
11 LCD backlight
LED display illumination can be varied with 3 different settings: AUTO:
Display illumination switches off during periods of inactivity and
switches on again automatically for measurement procedures. ON: Display
illumination remains on permanently. OFF: Display illumination remains off
permanently. The setting is stored and remains in effect until it is changed
manually.
12 AUTO OFF function
The AUTO-OFF function has 3 different settings:
ON: The device switches off automatically after 3 minutes
OFF: The device does not switch off automatically
AUTO: The device does not switch off automatically; after switching off
manually, this function is set back to ,,ON” and, after switching on, the
device again switches off automatically after 3 minutes.
13 Self-test function
14 Instruction for use – resistance measuring principle
14.1 Measuring material moisture
Be sure neither supply lines (electric lines, water pipes, etc) nor a metal subsurface is present at the location to be measured. Insert the electrodes as far into the material as possible but never use excessive or sudden impact force as this could damage the device. Always pull the device out of the material with left/right twisting motion. Perform several comparative measurements at different locations to minimise measurement error. The sharply pointed electrodes present an injury hazard. Always put the safety cap on the device when it is not in use or being transported.
14.2 Wood
The location to be measured should be untreated, free of knots, dirt and resin. Measurements should not be made on the end faces of wood because these areas dry particularly quickly such that they produce incorrect measurement results. Perform multiple comparative measurements. Wait until the % symbol stops blinking and remains constantly lighted. Only then are measurement values stable.
14.3 Mineral building materials
Be aware that walls (or surfaces) with differing material structures, or even variations in material composition, can cause measurement results to be falsified. Perform multiple comparative measurements. Wait until the % symbol stops blinking and remains constantly lighted. Only then are measurement values stable.
15 Instruction for use – capacitive measuring principle
– Make sure that the sensor pads make good contact with the material with no
air inclusions.
– The contact pressure compensates for unevenness of the surface and small
dust particles.
– Measured surface should be free of dust and dirt
– Always take spot measurements while exerting a contact pressure of 2.5 kg.
– For quick checks, while exerting light pressure, you can slide the device
over the surface. (Look out for nails and pointed objects! Danger of injury
and damage to sensor pads!) Measure again at the highest deflection point
while applying 2.5 kg contact pressure.
– Keep at least a 5 cm distance from metal objects
– Metal pipes, electric lines and reinforcing steel can falsify measurement
results
– Always measure at several different spots
Wood: The measured depth in wood is 30 mm maximum but does vary somewhat
with differing wood densities. Measurements made on thin wood boards should,
if possible, be made on a stack of these boards as otherwise the measurement
will be too low. Measurements made on installed wooden structures are
influenced by the structural conditions and their chemical treatments (e.g.
paints) with various materials. Thus such measurements should only be viewed
relatively.
Maximum accuracy is achieved between 6% and 30% wood moisture. In very dry
wood (< 6 %) irregular moisture distribution can be detected, in very wet wood
(> 30 %) saturation of the wood fibres begins.
16 General instruction for use
The operating principle of the device can only determine the material moisture measurement in % and show the moisture content on the LED display when the material matches the specified internal material characteristics.
Material relative moisture reference values, in %, for use with wood:
– Outdoor usage: 12% … 19%
– Use in unheated rooms: 12% … 16%
– In heated rooms (12 °C … 21 °C): 9% … 13%
– In heated rooms (> 21 °C): 6% … 10%
This moisture measuring device is a sensitive tool. This means that the measurement results may be subject to slight deviations when someone touches the device with their hand or when contact is broken between the device and the material being measured. However, contact with the user’s hand forms the basis for calibrating the measuring device, so we recommend holding onto the device whilst taking your measurements.
Functional and operational safety is only warranted when the instrument is operated within the specified climatic conditions and is only used for those purposes for which it is designed. The assessment of measurement results and actions taken as a consequence lie in the user`s scope of responsibility, depending on the given type of work.
Data transfer
The device features a Bluetooth® function that enables wireless data transfer
to mobile devices with a Bluetooth® interface (such as a smartphone or
tablet). The system prerequisites for a Bluetooth® connection are specified
at http://laserliner.com/info?an=ble The device can set up a Bluetooth®
connection with Bluetooth 4.0 compatible devices. The range is set to a
maximum distance of 10 m from the terminal device and greatly depends on the
ambient conditions such as the thickness and composition of walls, sources of
interference as well as the transmit / receive properties of the terminal
device. Once it has been activated, Bluetooth®* remains switched on
indefinitely as the radio system is designed with exceptionally low power
consumption. A mobile device can link up to the active measuring device via an
app.
Application (app)
An app is required to use the Bluetooth®* function. You can download the app
from the corresponding stores for the specific type of terminal device:
http://videos.press-and-test.de/Dmc_Portal_de/
! Make sure that the Bluetooth® interface of the mobile device is activated. After starting the app and activating the Bluetooth® function, a connection can be set up between a mobile device and the measuring device. If the app detects several active measuring devices, select the matching device. This measuring device can be connected automatically the next time it is switched on.
- The Bluetooth® word mark and the logo are registered trademarks of Bluetooth SIG Inc
Technical data
EU directives and disposal
This device complies with all necessary standards for the free movement of
goods within the EU.
This product is an electric device and must be collected separately for
disposal according to the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=muwemacopl
MultiWet-Master Compact Plus
SERVICE
Umarex GmbH & Co. KG Laserliner Möhnestraße 149, 59755 Arnsberg,
Germany
Tel.: +49 2932 638-300,
Fax: +49 2932 638-333
info@laserliner.com
Umarex GmbH & Co. KG Donnerfeld 2 59757 Arnsberg, Germany
Tel.: +49 2932 638-300,
Fax: -333
www.laserliner.com
References
Read User Manual Online (PDF format)