FOAMit FI-WC-11AP High Concentration Foam Unit with All-Poly Fittings User Manual

June 9, 2024
FOAMit

FOAMit FI-WC-11AP High Concentration Foam Unit with All-Poly Fittings

FOAMit-FI-WC-11AP-High-Concentration-Foam-Unit-with-All-Poly-Fittings-
PRO

WARNING

Read this manual completely and understand the machine before operating or servicing it.

  • Read all instructions before installing or operating unit.
  • Always wear appropriate personal protective equipment (PPE) when operating or servicing unit.
  • Always follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and Safety Data Sheet (SDS).
  • If this unit is modified or serviced with parts not listed in this manual, the unit may not operate correctly.
  • Never point the discharge wand at yourself, another person, or any object you do not want covered in chemical.
  • Always depressurize unit after use (as described in the After Use Instructions). Always store unit depressurized, with the discharge valve in the closed position.
  • Do not exceed an incoming air pressure of 100 psi (7 bar).
  • Do not exceed a fluid temperature of 100˚F (37˚C).
  • Always flush the unit with fresh water for 2-4 minutes when switching from an alkaline to an acid or an acid to an alkaline.
  • Only use clean and dry air. Air must be filtered and free of moisture or pump life will be diminished. If needed, install an air dryer before unit.
  • Do not use an air lubricator before the unit.
  • Never use unit with hydrocarbons or flammable products.

PROTECT THE ENVIRONMENT
Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations.

OPTIONS: (unit with 1-product pick up)

 | Pump Seal Material

FI-WC-11AP

| Santoprene (standard)
Viton (V)
Kalrez (K)
Add bold option codes to item number as shown. For standard options, no option code is needed.

Examples:

•      FI-WC-11AP (standard unit with Santoprene pump seals)

•      FI-WC-11APV (unit with Viton pump seals)

OPTIONS: (unit with 2-products pick up)

 | Pump Seal Material|

FI-WC-11AP

| Santoprene (standard)|

2

Viton (V)
Kalrez (K)
Add bold option codes to item number as shown. For standard options, no option code is needed.

Examples:

•      FI-WC-11AP2 (standard unit with Santoprene pump

seals)

•      FI-WC-11APK2 (unit with Kalrez pump seals)

REQUIREMENTS

Compressed air requirements| 40-80 psi (2.8-5.5 bar) with 5-10 cfm (141.6-283.2 l/min)
Water requirements| 10-100 psi (0.7 – 6.9 bar)

Backflow prevention is required – consult local plumbing ordinances for more information.

Liquid temperature range| 40-100˚F (4.4-37.8˚C)
Chemical compatibility| Chemical products used with this equipment must be formulated for this type of application and compatible with unit materials and pump seals. For more information on chemical compatibility, consult the manufacturer or MSDS for your product or contact our customer service department.
SPECIFICATIONS

 | FI-WC-11AP| FI-WC-11AP2
Power type| Compressed air
Chemical pickup type| Draws from concentrated product
Dilution ratio range (water:chemical)| 1:1 to 16:1
Number of products unit can draw from| One product| Two products, one at a time
Suction line length/diameter| 8 ft. (2.4 m) clearbraid hose with 1/2 in. (12.7 mm) inside diameter (for each product)
Discharge hose diameter/length| 50 ft. (15.2 m) hose, with 3/4 in. (19 mm) inside diameter
Discharge wand/tip type| 32 in. (81.3 cm) polypropylene wand with zero tip and polypropylene ball valve
Output distance| 15-20 ft. (4.6-6.1 m)
Output volume| 20 gal/min (75.7 l/min) of foam
Flow rate
| 1.6 gal/min (6.1 l/min)
Pump seals| Santoprene, Viton, or Kalrez
Fluid fittings type| All-poly

Installation Instructions

  1. Remove all components from packaging.

  2. Select desired area to mount the control box.
    Note: We recommend mounting the control box at a height of 6 feet or less. The chemical suction lines must reach the bottom of the chemical container. The bottom of the chemical container should not be positioned higher than the bottom of the control box.

  3. Attach the control box mounting feet to the back of the control box, using the four screws provided in the parts package.

  4. Mount the control box to the wall using four of the screws and plastic anchors provided in the parts package. Note: To drill holes for the plastic anchors, use a 5/16 inch drill bit.

  5. Mount the hose hanger in a convenient location using the remaining two screws and anchors provided in the parts package.

  6. Attach the discharge hose assembly to the discharge hose barb (HB1234) and secure it with the larger hose clamp provided in the parts package.

  7. Connect the air inlet hose barb (HBSS1438) provided in the parts package to the air inlet valve (BVB14) located on the side of the control box. Then attach a 3/8 inch I.D. air line from your air compressor to the air inlet hose barb, and secure it with the smaller hose clamp provided in the parts package.

  8. Connect a water line to the water inlet fitting (SNB34GH). Note: A back-flow preventer must be installed in the water line – check local plumbing codes to ensure proper installation.

  9. Insert the proper metering tips and connect the chemical intake lines to the inlet barbs. Note: Use the included metering tip color charts to determine the appropriate metering tip based on the product and dilution rate you will be using.

  10. Place the other end of each chemical intake line into a chemical container.

METERING TIP COLOR CHART

Metering Tip Color

| Diameter

(Inches)

| Ratios (Water:Chemical)**
NO TIP| NO TIP| 1:1
GREY| 0.128| 1.5:1
BLACK| 0.098| 2.25:1
BEIGE| 0.07| 3.25:1
RED| 0.052| 4.25:1
WHITE| 0.043| 6.5:1
BLUE| 0.04| 7.5:1
TAN| 0.035| 9:1
GREEN| 0.028| 11:1
ORANGE| 0.025| 16:1
BROWN | 0.023| 22:1
YELLOW
| 0.02| 27:1
PURPLE | 0.014| 43:1
PINK
| 0.01| 53:1
* Use of these metering tips is not recommended. At ratios greater than 16:1 (water:chemical), the output volume of the unit may be greatly reduced.

** Injection rates will vary based on chemical viscosity, air pressure, and many other factors. We recommend testing unit output to verify injection rate prior to use.

Operation Instructions

  1. Slowly open the discharge valve (HV34) to begin foaming. The discharge valve should be completely open while foaming.
  2. Adjust the needle valve (NV14Y), located inside the control box, to regulate the wetness or dryness of the foam following the steps below:
    • a. Close needle valve (NV14Y) completely in clockwise direction.
    • b. Open needle valve (NV14Y) in counter-clockwise direction 3 complete turns.
    • c. Continue to open needle valve in ¼ turn increments, allowing 30 seconds between adjustments, until desired consistency of foam is achieved.

After Use Instructions:

  1. Place the chemical suction line into a container of water.
  2. Open the discharge valve (HV34), and allow the unit to be flushed with water for approximately 2-4 minutes or until all chemical has been discharged from system.
  3. Close air inlet valve (BVB14).
  4. Shut off the water supply to the unit.
  5. Open the discharge valve to relieve any pressure remaining in the unit.
  6. Close the discharge valve after all pressure has been relieved from the unit. Store the unit with the discharge valve in the closed position.

Maintenance Instructions

To keep your foam unit operating properly, periodically perform the following maintenance procedures:
Note: Before performing any maintenance, ensure that the unit has been disconnected from the air/water supply and depressurized according to the “After Use Instructions” above.

  • Inspect the pump (P56/P56K/P56V) for wear and leaks.
  • Inspect all hoses for leaks or excessive wear. Make sure all hose clamps are in good condition and properly secured.
  • Replace the filter located within the air regulator (R25) as needed. Clean by unthreading the air regulator bowl from the air regulator (R25).
  • Check the chemical metering tips, intake lines and strainers for debris and clean as needed.
  • Drain the air compressor tank on a regular basis to help extend pump life. An air source with a high moisture content will accelerate pump wear.
    Note: If the air source has a high moisture content, you may wish to install a water separator (WS-20CFM) before the unit.

Troubleshooting Instructions

  • Check to ensure that the discharge hose is uncoiled properly, and that there are no kinks that could obstruct fluid flow.

  • Check the air regulator bowl and air filter for debris such as water, oil, or rust particles. Clean by unthreading the air regulator bowl from the air regulator (R25).

  • If air passes through the pump (P56/P56K/P56V) without cycling, the pump needs to be replaced.

  • If solution backs up into the air regulator bowl, the check valve (CV38-AP) needs to be replaced.

  • Check for proper air pressure on the air gauge (AG100). The air regulator (R25) is factory set at 50 psi (3.4 bar). Operating range is 40 to 80 psi (3 to 5 bar) with 5 to 10 CFM (141.6 to 283.3 l/min).

  • If the unit operates at a reduced pressure:

    • Check the air compressor supplying the unit. If the pressure is less than 40 psi (3 bar), turn the unit off until the compressor can catch up.
    • If the air supply is 50 psi (3.4 bar) or above, check the air gauge (AG100), which should read near 50 psi (3.4 bar). If the air gauge reads more or less than 50 psi (3.4 bar), adjust the pressure by turning the knob on the top of the air regulator (R25).
  • Check the chemical metering tips, intake lines and strainers for debris or damage. Clean or replace as needed. To prevent damage to the unit, strainers must always be used.

  • Make sure proper foaming chemical and concentration are being used.

  • If the needle valve (NV14Y) is open too far, the pump
    (P56/P56K/P56V) may cycle improperly due to lack of air pressure. If this occurs, close and readjust the needle valve (NV14Y) as described in Operation Instruction.

  • If foam comes out wet, no matter where the needle valve (NV14Y) is positioned, the check valve (CV38-AP) may need to be replaced.

  • Check for proper water pressure on the water pressure gauge (WRG14). To check the pressure:

    • With the unit running, open the discharge valve
      (HV60/HV34) and allow the unit to run for about 1 minute.

    • Close the discharge valve (HV60/HV34).

    • Check the water pressure gauge (WRG14). The pressure should read 30 psi (2.1 bar).

    • If necessary, adjust the water regulator using the flathead screw on the regulator body. The water pressure should be set at 30 psi (2.1 bar). Setting the pressure higher or lower may damage the unit or cause it to malfunction.

PARTS DIAGRAMS – UNITS WITH STANDARD FITTINGS

FOAMit-FI-WC-11AP-High-Concentration-Foam-Unit-with-All-Poly-
Fittings-1

PARTS DIAGRAMS

  1. PRODUCT PICK UP LINEFOAMit-FI-WC-11AP-High-Concentration-Foam-Unit-with-All-Poly-Fittings-2
  2. PRODUCT PICK UP LINEFOAMit-FI-WC-11AP-High-Concentration-Foam-Unit-with-All-Poly-Fittings-3

ZERO TIP FOAM WAND ASSEMBLY ITEM NUMBER: PWA32

50 ft (15 m) HOSE ASSEMBLY ITEM NUMBER: H34-50-AP

ANTI-KINK SPRING ASSEMBLY ITEM NUMBER: AKSS34

OPTIONAL COMPONENT
WATER SEPARATOR ITEM NUMBER: WS-20CFM

LEGACY WATER REGULATOR ASSEMBLY

ITEM NUMBER DESCRIPTION
AG100 1.5 INCH DRY MODEL 20 DUAL SCALE GAUGE
AKSS34-P SS ANTI-KINK SPRING FOR 3/4 INCH HOSE
AKSS-HPC ANTI-KINK STAINLESS STEEL HITCH PIN CLIP
BCVR1 10-32 X 1/2 PHIL PAN HEAD SS
BVB14 AIR INLET VALVE – VA BRS 025-4F4F-BT, NICKEL
CV12FM7-AP WHITE ½ INCH FEMALE NPT INLET – BLACK ½ INCH MALE NPT OUTLET – EP

SLEAS 7 PSI HASTELLOY SPRING
CV12-NS| 1/2in BARB X 1/2in BARB PVC CHECK VALVE – NO SPRING

– TEFLON BALL

CV38-AP| WHITE PVC CHECK VALVE 3/8 BARBS – HASTELLOY SPRING

– TEFLON BALL

EC14-2| OETIKER CLAMP 13.8
FR079| 687 SERIES FLOW RESTRICTOR – 0.79 GPM — FP FR

687-12F12F-E.79 GPM

FV2| FOOT VALVE, VITON, BLUE
FWLG14| .569 ID X 1.28 OD X .08 THICK FLAT WASHER SS 18-8
FWP12| 7/8 ID X 1.5 OD X 0.05 THK SSFW
FWP78| 7/8in BY .137 BY 1 1/4in FLATWASHER 18-8 PLN
H12CB| 1/2 IN (ID) CLEARBRAID RF SERIES
H14B-H| 1/4 INCH BLUE HOSE- GOODYEAR HORIZON – Available

per ft.

H34B-H| 3/4 INCH BLUE GOODYEAR HORIZON HOSE – Available

per ft.

H38B-H| 3/8 INCH BLUE GOODYEAR HORIZON HOSE – Available

per ft.

HB1234| 1/2in MPT X 3/4in HOSE BARB
HB1238| 1/2in MPT X 3/8in HOSE BARB
HB3434| POLY HOSE BARB 3/4in X 3/4in
HBEL1212-T| HOSE BARB ELBOW 1/2in MPT X 1/2in BARB – TAPPED FOR METERING TIP
HBEL1238| HOSE BARB ELBOW 1/2 X 3/8
HBELF1212-T| HOSE BARB ELBOW 1/2in BY FPT 1/2in – TAPPED FOR METERING TIP
HBSS1438| STAINLESS HOSE BARB 1/4 MPT X 3/8 BARB
HBSSEL1438| STAINLESS HOSE BARB ELBOW 1/4 INCH NPT X 3/8 HOSE

BARB

HBSSEL1814| 304 STAINLESS ELBOW 1/8 INCH NPT X 1/4 INCH HOSE

BARB

HHPB1214| HEX HEAD POLY REDUCER BUSHING 1/2in X 1/4in
HHSB34GH12| STAINLESS HEX HEAD BUSHING 3/4in MGH BY 1/2 FPT
HV34| 3/4in POLY BALL VALVE
HV50-3| 3-WAY BALL VALVE – 1/2 INCH – FIBER GLASS RE- ENFORCED POLYPROPELENE BODY – TEFLON SEATS – EPDM O-RING
HV50-3-BRKT| SS BRACKET FOR HV50-3
MTK 511| METERING TIP KIT – 511/530
N1032| 10-32 HEX MACH SCREW NUT 18-8
NV14Y| FLOW CONTROL VALVE – INCLUDES BLACK KNOB
NV14Y- HNDL| KNOB FOR 2839-1/4 NEEDLE VALVE
P56| 5700 PUMP WITH SANTOPRENE SEALS – INCLUDES HOSE BARBS, AIR FITTING, AND AIR PORT
P56K| 5700 PUMP WITH KALREZ SEALS – INCLUDES HOSE BARBS, AIR FITTING, AND AIR PORT
ITEM NUMBER| DESCRIPTION
---|---
P56V| 5700 PUMP WITH VITON SEALS – INCLUDES HOSE BARBS, AIR FITTING, AND AIR PORT
20756103B| Polypro G57 Air Port x HB Straight, w/ Viton o-ring
HB14P| 1/4in BRASS HB AIR FITTING /G57/P56
HB5638| HOSE BARB FOR P56 PUMP
HB5638K| HOSE BARB FOR P56K PUMP
HB5638V| HOSE BARB FOR P56V PUMP
P56-BRKT| PUMP BRACKET- STAINLESS STEEL
P56-BRKT-SCREW| HI LO SCREW FOR RETAINING P56-BRKT
PB16138| POLYPROPYLENE CONTROL BOX – WORKING DIMS 16x13x8 – PUMP MOUNT
PB16138-GSKT| NEOPRENE GASKET 0.220 INCH ROUND CORD STOCK –

61.125 INCHES

PB16138-LATCH| LATCH FOR PB16138
PB16138-PIN| STAINLESS STEEL HINGE PIN FOR CONTROL BOX PB16138 –

1/8 x 4 3/4 x 1/2inches

PBFT-PP| MOUNTING FEET FOR POLYBOX – PB16138 – POLYPROPYLENE
PL16138| CONTROL BOX LID – POLYPROPYLENE – 16x13x8 – HINGED LOCKABLE LID
PN1212| 1/2in MPT X 1/2in MPT POLY NIPPLE
PN3412| 3/4in MPT X 1/2in MPT POLY NIPPLE
PW32| 3/4in BLACK POLY PRO X 32in – FPTOE & MPTOE – SCH.80
R25| AIR REGULATOR – 1/4fpt TWO PORT 1/8fpt TWO PORT – INCLUDES FILTER AND BOWL
AFR25| AIR FILTER for R25
ABR25| METAL AIR BOWL for R25
R25DT| 3/16 X 5/16 CLEAR PVC TUBING – Available per ft.
S1034FHL| 10 X 3/4 PHIL FLAT HI-LO THRD SCREW 18-8
SA12B| GARDEN HOSE SWIVEL ADAPTER X 1/2 MPT
SHW3| 3in LONG COATED WEIGHT
SN1414| STAINLESS 1/4MPT X 1/4MPT NIPPLE
SNB34GH| BRASS 3/4 GH SWIVEL NUT
SSA12| STAINLESS MALE/FEMALE S.S. ADAPTOR 1/2in X 1/2in
SSA14| SS304 MALE/FEMALE ADAPTOR 1/4 NPT X 1/4 NPT
SSC12| WORM GEAR CLAMP, S/S (.31-.91)
SSC34| WORM GEAR CLAMP, S/S (.75-1.25)
SSC38| WORM GEAR CLAMP, S/S (.25-.63)
SSHH-F| S.S. LASER CUT HOSE HANGER – FLAT STOCK
STR34| 1in SEAL/STRAINER FOR 3/4 GH FITTINGS
T5| 1/2 POLY TEE
WMS14| 14 X 1 1/4 HEX W/H SMS SLOTT, S/S
WMS14A| 5/16 X 1 1/2 STRAIGHT PLASTIC ANCHOR
WR12SS| WATER PRESSURE REGULATOR – STAINLESS STEEL – 1/2 INCH FPT
WR15G34| WATER PRESSURE REGULATOR – 3/4in FGH BY 3/4in MPT

Body ABS, internal parts, SS, PP and Santo

WRG14| WATER PRESSURE REGULATOR GAUGE FOR WR12SS
WS-20CFM| TSUNAMI WATER SEPARATOR 20 CFM

Model Number: FI-WC-11AP, FI-WC-11AP2 AND RELATED UNITS