LS-E-EU Series-5A-30A PWM Charge Controller
※ Thank you for selecting the LandStar E/EU series solar charge
controller. Please read this manual carefully before using the product and pay
attention to the safety information.
※ Do not install this product in humid, salt spray, corrosion, greasy,
flammable, explosive, dust accumulative, or other severe environments.
Solar Charge Controller
Safety Information
- Read all the instructions in the manual before installation.
- DO NOT disassemble or attempt to repair the controller.
- Install an external fast-acting fuse or breaker as required.
- Disconnect the solar module and fast-acting fuses/breakers near the batterybefore installing or moving the controller.
- Power connections must remain tight to avoid excessive heating from a loose connection.
- Only charge batteries that comply with the controller’s parameters.
- The battery connection may be a single battery or a bank of batteries.
- Risk of electric shock! The PV and load can produce high voltages when thecontroller is working.
Overview
The LandStar E/EU series controller is a PWM charge controller that adopts the most advanced digital technique. It’s an easy operation and cost-efficient controller featured as:
-
3-Stage intelligent PWM charging: Bulk, Boost/Equalize, and Float
-
Support 3 charging options: Sealed, Gel, and Flooded
-
Battery status LED indicator indicates battery situation
-
Battery temperature compensation function
-
With humanized settings, the operation is more comfortable and convenient
-
The USB provides a power supply that can charge electronic equipment(LS
EU series only) -
Battery type and load output can be set via the button
-
Extensive Electronic protection
Product Features
1 | PV Terminals | 6 | Load Switch Button |
---|---|---|---|
2 | Battery Terminals | 7 | Battery status LED indicator |
3 | Load Terminals | 8 | Load status LED indicator |
4 | USB output interface | ||
(LS EU series only) | 9 | Charging status LED indicator | |
5 | Mounting Hole Φ4.5 |
Wiring
Connect the system in the order of ❶battery load PV array following Figure
2-2,” Schematic Wiring Diagram,” and disconnect the system in the reverse
order❸❷❶.
NOTE: Do not connect the circuit breaker or fast-acting fuse while wiring
the controller. Ensure that the leads of “+” and “-” poles are connected
correctly.
NOTE: A fast-acting fuse whose current is 1.25 to 2 times the
controller’s rated current must be installed on the battery side with a
distance from the battery not greater than 150 mm.
WARNING: The controller has no PV reverse connection protection; please
connect it correctly.
LED Indicators
- Charging and load status indicator
Indicator| Color| Status| Instruction
---|---|---|---
Charging status LED indicator| Green| On Solid| In Charging
OFF| No Charging
Fast Flashing| Battery Over
Voltage
Load status LED indicator| Green| On Solid| Load ON
OFF| Load OFF
Slowly Flashing| Overload
Fast Flashing| Load short circuit - Battery status indicator
LED1| LED2| LED3| LED4| Battery Status
---|---|---|---|---
Slowly Flashing| X| X| X| Under voltage
Fast Flashing| X| X| X| Over-discharge
| Battery LED indicator status during voltage is up
0| | 0| X| X| 12.8V< Ubat<13.4V
0| | 0| 0| X| 13.4V< Ubat<14.1V
0| | 0| 0| 0| 14.1V < Ubat
| Battery LED indicator status during voltage is down
0| | 0| 0| X| 12.8V<Ubat<13.4V
0| | 0| X| X| 12.4V<Ubat<12.8V
0| | X| X| X| Ubat<12.4V
NOTE:
① The above voltage values are measured in the 12V system at 25℃; please
double the values in the 24V system.
② “○” states LED indicator on; “×” states LED indicator off.
Operating
- Load ON/OFF Setting Press the button to control the load output when the controller is powered on.
- Battery Type Setting
Operation:
Step 1: Enter the setting mode by pressing the button for 5s until the
battery status LEDs are flashing.
Step 2: Select the desired mode by pressing the button.
Step 3: The mode is saved automatically without any operation for 5S, and
the LED stops flashing. Battery Type Indicator shows as below:
LED1 | LED2 | LED3 | Battery type |
---|---|---|---|
0 | X | X | Sealed(Default) |
0 | 0 | X | Gel |
0 | 0 | 0 | Flooded |
NOTE: “○” states LED indicator on “×” states LED indicator off
Battery Voltage Control Parameters Below parameters are measured in the 12V
system at 25 ºC; please double the values in the 24V system
Battery Type | Sealed | Gel | Flooded |
---|---|---|---|
Over Voltage Disconnect Voltage | 16.0V | 16.0V | 16.0V |
Charging Limit Voltage | 15.0V | 15.0V | 15.0V |
Over Voltage Reconnect Voltage | 15.0V | 15.0V | 15.0V |
Equalize Charging Voltage | 14.6V | —— | 14.8V |
Boost Charging Voltage | 14.4V | 14.2V | 14.6V |
Float Charging Voltage | 13.8V | 13.8V | 13.8V |
Boost Reconnect Charging Voltage | 13.2V | 13.2V | 13.2V |
Low Voltage Reconnect Voltage | 12.6V | 12.6V | 12.6V |
Under Voltage Warning Reconnect Voltage | 12.2V | 12.2V | 12.2V |
Under Voltage Warning Voltage | 12.0V | 12.0V | 12.0V |
Low Voltage Disconnect Voltage | 11.1V | 11.1V | 11.1V |
Discharging Limit Voltage | 10.6V | 10.6V | 10.6V |
Equalize Duration | 120 min. | —— | 120 min. |
Boost Duration | 120 min. | 120 min. | 120 min. |
Protection
-
Battery Over Voltage Protection
When the battery voltage reaches the Over Voltage Disconnect Voltage(OVD), the controller stops charging the battery to protect the battery from being overcharged. -
Battery Over Discharge Protection
When the battery voltage reaches the Low Voltage Disconnect Voltage(LVD), the controller stops discharging the battery to protect the battery from being over-discharged. -
Overload Protection
The load is switched off after a delay when the load current exceeds 1.25 times the rated current. The user must reduce the load appliance, press the button, or restart the controller. -
Load Short Circuit Protection
The load is switched off when the load short circuit (≥3 times the rated current) happens. The user must clear the short circuit faults, press the button, or restart the controller. -
High Voltage Transients Protection
The controller is protected against small high voltage transients. In lightning-prone areas, an external lightning arrester is recommended.
Troubleshooting
Faults | Possible reasons | Troubleshooting |
---|
The charging LED turns off during the daytime when sunshine falls on PV
modules properly.| PV array disconnection| Confirm that PV and battery wire
connections are correct and tight.
No LED indicator| Battery voltage may be less than 8V| Measure battery voltage
with the multi-meter. Min.8V can start up the controller.
Charging LED fast flashes.| Battery over voltage| Check if the battery voltage
is higher than the OVD, and disconnect the PV.
LED1 fast flashes.| Battery over-discharged| The load will recover when the
battery voltage is restored to or above the LVR (low voltage reconnect
voltage).
Load LED flashesslowly.| Overload*| 0 Please reduce the number of electric
equipment.
C) Press the button or restart the controller.
Load LED fastflashes.| Load short circuit| (i) Check carefully loads
connection, clear the fault.
® Press the button or restart the controller.
- When the load current exceeds 1.25 times, 1.5 times, and 2 times the rated value, the controller can automatically turn off loads after 60s, 5s, and 1s, respectively.
Disclaimer
This warranty does not apply under the following conditions:
- Damage from improper use or use in an unsuitable environment.
- PV or load current, voltage, or power exceeds the controller’s rated value.
- User disassembly or attempted to repair the controller without permission.
- The controller is damaged due to natural elements such as lighting.
- The controller is damaged during transportation and shipment.
Technical Specifications
Item| LS0512E| I LS1012E| LS1024E| I LS2024E|
LS0512EU| I LS1012EU| LS1024EU| I LS2024EU| I LS3024EU
---|---|---|---|---|---|---|---|---|---
Nominal system voltage| 12VDC| 12/24VDC Auto| 12VDC| 12/24VDC Auto
Rated charge current| 5A| 10A| 20A| 5A| 10A| 20A| 30A
Rateddischarge current| 5A| 10A| 20A| 5A| 10A| 20A| 30A
Battery input voltage range| 8V – -16V| 8V- 32V| 8V – -16V| 8V – -32V
Max. PV open circuit voltage| 30V| 50V| 30V| 50V
Self-consumption| 12V55mA; 24V57mA
Charge Circuit Voltage Drop| 50.21V| 50.13V
Discharge Circuit Voltage Drop| 50.12V| 50.17V
USB input interface| —| 5VDC/1.2A| I 5VDC/2A
Temperature compensation coefficient| -5mV/C/2V
Environment temperature| -35-C — +50`C
Humidity| 595°/0,(N.C.)
Enclosure| IP30| IP20
Grounding| Common Positive
Dimension(L x W x H)| 92.8×65
x20.2mm| 101.2×67 x21.8mm| 101.2×67
x21.8mm| 128×85.6
x34.8mm| 109.7×65.5
x20.8mm| 120.3×67
x21.8mm| 120.3×67 x21.8mm| 148×85.6
x34.8mm| 148×106.8 X43.7mm
Mounting size| 84.4mm| 92.7mm| 92.7mm| 118mm| 100.9mm| 111.5mm| 138mm
Mounting hole size| 04.5
Terminals| 14AWG/2.5mm=| 12AWG/4mm=| 12AWG/4mm=| 1OAWG/6mm=| 14AWG/2.5m m=|
12AWG/4mm=| 12AWG/4mm=| 1OAWG/6mm=| 8AWG/10mm=
Net weight| 0.07kg| 0.08kg| 0.08kg| 0.15kg| 0.09kg| 0.10kg| 0.10kg| 0.18kg|
0.29kg
Any changes without prior notice! Version number: V4.2