Ampeak BC0253 Smart Battery Charger Instruction Manual

June 9, 2024
Ampeak

Ampeak BC0253 Smart Battery Charger Instruction Manual
Ampeak BC0253 Smart Battery Charger

WELCOME

Thank you for purchasing Ampeak BC0253 Smart Battery Charger. Please save these instructions for future use. If any issues arise during product use, just feel free to contact us via customer.services@ampeak.com

ABOUT Ampeak SMART CHARGER

Ampeak BC0253 is a smart battery charger ideal for 12V STD, AGM, and GEL batteries. With intelligent 8 charging stages and multiple assist functions, it will smartly identify, charge, repair, and maintain your batteries. Fully- automatic features, manual selections, prior-setting memory, auto-stop when 100% charged, and auto-awake to pulse compensate after voltage drops enrich your pleasant charging experience.

WARNINGS

  • PLEASE READ CAREFULLY AND UNDERSTAND ALL SAFETY INFORMATION BEFORE USING THIS PRODUCT. Failure to follow these safety instructions may lead to Electrical Shock, Explosion, and Fire, which can result in property damage, serious injury, and even death.

  • Electrical Shock – The battery charger is an electrical device that may shock and cause serious injury. Do not use the charger if the power cords are damaged. Do not submerge in water or get wet.

  • Explosion – Do not attempt to charge any frozen, damaged, incompatible batteries. Never try to charge lithium batteries with high-voltage shock. Apply the charger only to batteries with recommended voltage.

  • Fire – Use the product in well-ventilated areas. Do not cover the product. Do not smoke or use any source of electrical spark or fire when using the charger. Keep product away from flammable materials.

  • Eye Injury – Wearing eye protection to use the charger is recommended. Batteries can explode and cause flying debris. Battery acid can cause eye and skin irritation. If needed, flush affected areas with running clean water and contact medical aid in time.

  • Explosive Gases – Batteries may generate explosive gases during normal battery operation. Please follow all safety instructions and also those published by the battery manufacturer. Review cautionary markings on these products and on the engine.

Product Overview

Product Overview
LCD Display Overview

PACKAGE OVERVIEW

  • One Ampeak Smart Battery Charger with Battery Clips

  • One Instruction Manual

SPECIFICATIONS

Low Voltage Detection 1V
Input AC 120V/60Hz, 9A
Output DC 12V, 2A/10A/25A/Automatic
Efficiency 84%
Type of Batteries 12V ONLY
Charging Progress Smart 8 Stages
Working Temperature 32°F/0°C ~ 104°F/40°C
Battery Types STD AGM GEL
Battery Capacity Up to 1000Ah; Maintain All Battery Sizes

CHARGING TIMES

The size of the battery (Ah) and its depth of discharge (DOD) greatly affect its charging time. The estimated charging time shown below is based on an average discharge depth of 50% to a fully charged battery and is only for reference purposes. Actual data may differ due to battery conditions and temperature. The charger has “24H Overtime Charging Protection”.

Battery Size Ah(Amp Hour)| ApproximateTime To Charge In Hours


---|---
2A **| 10A **| 25A
25| 12.3| 2.3| 0.75
50| 24.5| 4.5| 1.5
100| –| 9.0| 3
200| –| 18.0| 6
500| –| –| 15
1000| –| –| 30

OPERATING INSTRUCTIONS

Automatic Charging

  1. Connect the battery clips to the battery terminals. Red clip to the positive terminal (+), and black clip to the negative terminal (-).
  2. Plug the battery charger into the 120V AC outlet. Without any manual selections, the smart charger will take about 30 seconds to automatically identify and charge your battery with the optimal settings (2A & STD).

NOTE: The battery charger has prior-setting memory function. If you hav already charged a battery before and have not reset new modes for a new charging, it will automatically adopt your initial settings for the new charging.

Manual Charging

  1. Connect the battery clips to the battery terminals. Red clip to the positive terminal (+), and black clip to the negative terminal (-). Plug the battery charger into the 120V AC outlet.
  2. Select your desired charging rate, compatible battery and press “START”  button to start charging. All the data will be shown on the LCD screen.
  3. During the charging, you can press “Recondition” button to check the smart 8 charging stages. It will automatically switch back to the main interface in 5 seconds.
  4. If you would like to reset the charger during the charging, first press “START” button to pause charging, reset your desired modes, and then press “START” button again to continue charging.
  5. The battery power percentage on LCD display will be 100% once your battery is fully charged. Then the charger will auto-stop charging in this case.
  6. Regarding a long-term connection and charging, the smart charger will auto-restart to pulse maintain battery to 100% full again when it detects voltage dropping. Auto-stop charging when it is 100% full again

Smart 8-Stage Charging Program
Charging Program

  • Battery Desulfation – Adopt 15.8V pulse voltage for electrolytic removal of sulfated crystals. Automatically skip when not needed.

  • Soft Start – A slow and steady buildup of the charging process that limits the power input to protect your battery.

  • Bulk Charging – The main part of the whole charging process where the battery power will reach about 80% full.

  • Absorption – Fully charge the battery by slowly reducing the charging rate to allow your battery to absorb more power.

  • Battery Analysis – Auto-test the battery state after charging. Abnormal – enter the repair stage; Normal – turn to the next stage.

  • Battery Recondition – Restore over-discharged batteries. After repair, return to the “Bulk” stage. If it fails, an error will be reported.

  • Float Charging – Keep battery at 100% without overcharging or damages; Leave smart charger 24/7 plugged without worry.

  • Pulse Maintenance – Auto-wake up and pulse compensate to 100% full again when the voltage drops, with battery more durable.

  • Winter Mode Charging
    Ampeak smart battery charger, adding 0.2v more on the basis of the initial charging voltage, better boosts your battery activity and charges more thoroughly in low-temperature situations.
    Winter Mode Charging
    After connecting the battery charger to both your battery and the AC outlet, press “AMPS” button to select your desired charging rate, press “Battery Type” button to choose the compatible battery, then press ” ” to select winter mode charging, and press “START” button to start charging. All the data will be shown on the LCD screen.

  • Battery Recondition
    The “Recondition” function is for recovering idled or unused batteries that are deeply discharged, thus helping the battery last longer. Battery repair time up to 4 hours and “Battery Failure” will be reported if it fails to repair in 4 hours.
    Battery Recondition
    With the repair completed, you can directly press “START” button to start
    charging. Or you just wait for about 30 seconds, the battery charger will automatically switch to the charging status.

  • Battery Desulfation
    The smart battery charger will identify and restore severely-sulfated battery terminals to rehabilitate the lost performance. Battery desulfation time up to 24 hours and “Battery Failure” will be reported if it fails after 24 hours. This mode will automatically skip and switch to the next stage if your battery does not need to be desulfated.
    Battery Desulfation
    With the desulfation completed, you can directly press “START” button to start charging. Or you just wait for about 30 seconds, the battery charger will automatically switch to the charging status.

  • Engine Start Aid
    Engine start aid helps in activating your car battery with insufficient power to emergently start your vehicle in 100 seconds. You need to grasp the prompt in the picture below and start your car synchronously. If you miss this interface, you may not be able to start normally.
    Engine Start Aid

Operation Details:

  1. Select your battery type, press “Engine Start” button, the LCD screen will show and then press “START” button. LCD screen shows as follows. It switches to the 100s-count-down interface. You need to wait.

  2. In the 60-second interface, it will immediately show the prompt picture below. Now you need to simultaneously start your car.
    Operation Details

  3. If you fail to start your car for the first time, you need to wait for the 30S interface for a second attempt. Now you also need to seize the moment and simultaneously start your car.
    Operation Details

  4. If you fail to start your car for the second time, you need to wait until the count-down is over and show the prompt picture again for a third attempt.

If you fail to start your car in the three attempts above, the LCD display will show as follows. This is the whole working cycle for the “Engine Start” function. In this case, if you still want to have a try again, press “Engine Start” and “START” buttons again, then repeat previous steps.

TROUBLESHOOTING

Failure| Possible Cause|

Corrective Action

---|---|---
|

  1. The desulfurization stage exceeds 4h.
  2. Abnormal battery charging in soft start stage.
  3. Charging timeout in constant voltage phase(24H)
  4. Timeout in the repair phase(4H)
  5. Repair mode Repair timeout(4H)
  6. Desulphurization mode Desulphurization timeout(24H)

| Please replace the battery.
|

  1. Selected charging rate is too small for big-size battery;
  2.  The battery condition is not good.

|

  1. Select higher charging rate and recharge;
  2. Battery may be dead, check the battery condition. Replace battery if needed

| Clamps connected to wrong polarity| Correct the polarity to the right connection.
| The temperature of the charger is too high or the internal temperature sensor of the charger fails.| Make sure the vents are unblocked. The charger will recharge automatically after cooling down. If the charger has been unable to restore charging, the temperature sensor failure, by a professional maintenance personnel to check.
| Abnormal battery voltage.| Disconnect the AC power supply of the charger, let the battery stand for a period of time and then charge it again. If the same error occurs again, replace the battery.
| Abnormal charging current.| Disconnect the AC power supply of the charger, let the battery stand for a period of time and then charge it again. If the same error occurs again, replace the battery.

LIMITED WARRANTY

Ampeak brand series products are covered with a 30-day hassle-free return and an 18-month replacement on Amazon (With no man-made damage). For the defects reported during the warranty period, Ampeak will repair or replace the defective parts or items after technical analysis and confirmation.

Ampeak shall not be liable for any incidental or consequential damages arising from the disassembling, misuse, or modification of the device. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.

The limited warranty is void under the following conditions:

  • Misused, disassembled, altered, or repaired by unauthorized stores or technicians.
  • Careless handling and violation of operation.

Notice: All information in this manual is based on the latest information available at the time of publication and no warranty can be made for its accuracy or completeness. Ampeak reserves the right to make changes at any time without notice.

Ampeak Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals