Ampeak 1200W Pure Sine Wave Safe Power Inverter Instruction Manual

June 10, 2024
Ampeak

1200 Watts
Pure Sine Wave Safe Power Inverter
Instruction Manual

12-Volt DC to 110-Volt AC with
3AC Outlets and 2USB Ports

1200W Pure Sine Wave Safe Power Inverter

What is included?

EASY OPERATION STEPS

|
---|---
1. Make sure the inverter power switch is OFF.| 2. Connect the red positive (+) ring terminal cable to the red positive (+) terminals of the battery and inverter.
|
3. Connect the black negative (-) ring terminal cable to the black negative (-)terminals of the battery and inverter.| 4. Turn on the inverter power switch and plug in your appliance.

Make sure the inverter is turned OFF when not in use.

Applications

Load Appliance
(Do not power electric appliances which exceed 1200 watts.)|
Modified Sine Wave|
Pure Sine Wave
---|---|---
Refrigerator| |
Microwaver| |
Television| |
Audio| |
Printer| |

Specifications

Continuous output 1000 Watts
Max full load output 1200 Wafts
Surge output 2400 Watts
Input voltage DC 11V-15V
Output voltage AC 100V-120V
Low battery alarm 10.5V ± 0.5V
Low battery shut-off 9.5V± 0.5V
USB Output Current Dual 2.4A
High battery shut-off 16V± 0.5V
Fuse Mini fuse 4*40A

Attention

  1. When the input voltage is at 10.5V, the product will have an audible alarm intermittent low voltage warning reminder.
  2. When the voltage is lower than 9.5V or higher than 16V, the audible alarm will appear as a long warning.
  3. When the loaded equipment exceeds the power of the product itself, the audible alarm will show a long warning; At this time, the customer needs to adjust the power to work within the allowable power range, and after it lasts twice, the third time will enter the protection state, and the 1200 watts pure sine wave inverter needs to be restarted before it can work normally.
  4. This product has passed the ETL 1000 Watts ,while the max full load continuous output is 1200 Watts.

Sate Protections

1| | Busover Voltage
Protection| Internal control voltage at 250V, when the DC busvoltage is higher than 310V
Inverter stops working
Screen display BUSOVER VOLTAGE
Intermittent alarm for 60 seconds
Inverter will auto-shut down if the error is not processed in 60s
---|---|---|---
2| | Buslow Voltage
Protection| DC output busvoltage will be above 120V, when the DC busvoltage is below 80V
Inverter stops working
Screen display BUSLOW VOLTAGE
Intermittent alarm for 60 seconds
Inverter will auto-shut down if the error is not processed in 60s
3| | VCC Power Down
Protection| Inverter power down
Inverter stops working
Screen display VCCLOW VOLTAGE
Intermittent alarm for 60 seconds
Inverter will auto-shut down if the error is not processed in 60s
4| | Battery Over Voltage
Protection| Inverter power down
Inverter stops working
Screen display VCCLOW VOLTAGE
Intermittent alarm for 60 seconds
Inverter will auto-shut down if the error is not processed in 60s
5| | Battery Low Voltage
Protection| Input voltage = 16V
Inverter stops working
Screen display BATOVER VOLTAGE
Continuous alarm for 60 seconds
Inverter will auto-shut down if the error is not processed in 60s
6| | Output Over Current
Protection| Input voltage<9.5V
Inverter stops working
Screen display BATLOW VOLTAGE
Continuous alarm for 60 seconds
Inverter will auto-shut down if the error is not processed in 60s
7| | Output of
Inverter Overcool
Protection| Internal output electronic components of inverter temperature<-11°C/12.2°F
Inverter stops working
Screen display OVERCOOL
Intermittent alarm for 60 seconds
Inverter will auto-shut down if the error is not processed in 60s
8| | Output of
Inverter Overheat
Protection| Internal output electronic components of inverter temperature

105°C/221°F
Inverter stops working
Screen display OVERHEAT
Intermittent alarm for 60 seconds
Inverter will auto-shut down if the error is not processed in 60s
9| | Reverse Polarity
Protection| The positive and negative terminals of the inverter or battery are reversed
Inverter stops working
Screen display REVERSE POLARITY
No alarm remind
10| | Front Overcool
Protection| Internal Input electronic components of inverter temperature<-11°C/12.2°F
Inverter stops working
Screen display OVERCOOL
Intermittent alarm for 60 seconds
Inverter will auto-shut down if the error is not processed in 60s
11| | Front Overheat
Protection| Internal Input electronic components of inverter temperature 105°C/221°F
Inverter stops working
Screen display FRONT OVERHEAT
Intermittent alarm for 60 seconds
Inverter will auto-shut down if the error is not processed in 60s
12| | Output Short Circuit
Protection| Inverter stops working
Screen display SHORT CIRCUIT
Continuous alarm for 60 seconds
13| | Inverter Overvoltage
Protection| Output voltage = 130V
Inverter stops working
Screen display INVOVER VOLTAGE
Intermittent alarm for 60 seconds
Inverter will auto-shut down if the error is not processed in 60s
14| | Inverter Low Voltage
Protection| Output voltage< 90V
Inverter stops working
Screen display INVLOW VOLTAGE
Intermittent alarm for 60 seconds
Inverter will auto-shut down if the error is not processed in 60s
15| | Communication
Error
Protection| Communication error
Inverter stops working
Screen display COMMWARN
Intermittent alarm for 60 seconds
16| | Output Overload
Protection| Output wattage>1200W
Inverter stops working
Screen display OVERLOAD
Intermittent alarm for 60 seconds
Allow Two Restores Pragram locked
Permanently in the Third Time
Need to power off and restart
17| | Anti-Sparks| The positive and negative terminals of the inverter or
battery are reversed
No sparking during connect

LIMITED WARRANTY

18-MONTH LIMITED WARRANTY POLICY
18-Month Limited Warranty Policy is the only one that applies to this unit, and it sets forth all the responsibilities of Ampeak. There is no other warranty, other than those described herein.
Any implied warranty of merchant ability or fitness for a particular purpose on this unit is limited in duration to the duration of this warranty. This unit is warranted to the original purchaser only to be free of defects in materials and workmanship for 18-month from the date of purchase without additional charge. The warranty does not extend to subsequent purchasers or users.
Ampeak will not be responsible for any amount of damage in excess of the retail purchase price of the unit under any circumstances. Incidental and consequential damages are specifically excluded from coverage under this warranty. This unit is not intended for commercial use. This warranty does not apply to damage to units from misuse or incorrect installation/connection. Misuse includes wiring or connecting to improper polarity power sources.

RETURN/REPAIR POLICY
If you are experiencing any problems with your unit, please contact Ampeak Customer Service Department at: [email protected] returning the product to Amazon. After speaking to a customer service representative, if products are deemed non-working or malfunctioning, the product may be returned to amazon within 30 days of original purchase.
Any defective unit that is returned to Amazon within 30 days of the date of purchase will be replaced free of charge or fully refunded at the buyer’s option.
If such a unit is returned more than 30 days but less than 18-month from the purchase date, the manufacturer will repair the unit or at its option, replace it, free of charge. If the unit is repaired, new or reconditioned replacement parts may be used, at the manufacturer’s option. A unit may be replaced with a new or reconditioned unit of the same or comparable design. The repaired or replaced unit will then be warranted under the terms of the remainder of the warranty period.

LIMITATIONS
This warranty does not cover accessories, such as adapters and batteries, damage or defects resulting from normal wear and tear(including chips, scratches, abrasions, discoloration, or fading due to usage or exposure to sunlight), accidents, damage during shipping to our service facility, alterations, unauthorized use or repair, neglect, misuse, abuse, failure to follow instructions for care and maintenance, fire and flood.

IMPORTANT SAFETY INFORMATION

SAFETY STATEMENT
It is the responsibility of the owner to make sure all personnel read this manual prior to using the device. It is also the responsibility of the device owner to keep this manual intact and in a convenient location for all to see and read. If the manual or product labels are lost or not legible, contact AMPEAK for replacements or an electronic edition. If the operator is not fluent in English, the product and safety instructions shall be read and discussed with the operator in the operator’s native language by the purchaser owned or his designee, making sure that the operator comprehends its contents.
READ ALL WARNINGS AND FOLLOW ALL INSTRUCTIONS
BEFORE OPERATING THIS PRODUCT!
WARNING: RISK OF SHOCK, FIRE, AND EXPLOSION.
The inverter produces the same potentially lethal AC power as normal household outlets.
It is suggested that you treat it as a normal AC outlet.

  • DO NOT insert foreign objects into the AC outlet, the USB port, or the ventilation hole.
  • DO NOT use this product where there are flammable fumes or gases, such as in the bilge of a gasoline-powered boat, or near propane tanks.
  • NEVER smoke or allow a spark or flame in the vicinity of the engine or batteries.
  • Make sure the inverter wiring is of proper size and rating and in good condition. Operating the inverter with damaged wiring may void warranty.

CAUTION: PERSONAL SAFETY & EQUIPMENT DAMAGE.
KEEP AWAY FROM CHILDREN, THIS IS NOT A TOY.

  • DO NOT attempt to fix the unit by disassembling or modification. You can cause self-injury and disassemble and modifying the unit will void your warranty.
  • Disconnect DC power source from the inverter, before attempting to service, clean, or operate on any circuits connected to the inverter. Simply turning OFF the switch of the inverter will not disconnect the power, thereby causing electric shock.
  • Never connect the inverter to any power distribution systems or branch circuits.
  • DO NOT make any electrical connections or disconnections in areas designated as ignition protected. This unit is NOT approved for ignition-protected areas.
  • Connect the unit to a power source with a normal output of 12v DC ONLY. 6V battery voltages are too low and 24V battery voltages are too high, which will damage the unit.
  • DO NOT use the inverter in temperatures above 14°F (-10°C) – 113°F (45°C).
  • DO NOT expose this product to water, rain, snow, condensation, or spray.
  • DO NOT connect the unit to live AC power circuits or there will be damage to the inverter.
  • DO NOT connect any AC device which has its neutral conductor connected to the ground to the unit.
  • DO NOT use the inverter with medical devices since it is not approved for medical applications.
  • DO NOT permanently install the unit in the engine compartment. Certain chargers for small nickel-cadmium batteries can be damaged if connected to the inverter.
  • DO NOT use the inverter beyond its rated wattage capacity. Add the total watts of all connected appliances and be sure the total is less than the inverter’s capacity.

This product may contain one or more chemicals known to the state of California to cause cancer and birth defects or other reproductive harm. Wash hands thoroughly after handling.
NOTE:
If you are unsure about using your rechargeable appliance with the inverter, contact the Ampeak: [email protected] to determine the rechargeable appliances compatibility with the inverter.

Help Centre
Thank you for choosing Ampeak 1200 Watts Pure Sine Wave Safe Power Inverter. Please read this instruction carefully as they contain important information, and safety requirements. If you have trouble understanding the instructions, or have any questions regarding its operation, please contact our friendly customer support team, via [email protected]

| Facebook
ampea
---|---
| Official Website
www.ampeak.com
| Amazon
www.amazon.com/ampeak

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Ampeak User Manuals