ibx 10 Positions Multi-Position Magnetic Stirrer User Manual

June 9, 2024
ibx

ibx 10 Positions Multi-Position Magnetic Stirrer

ibx 10 Positions Multi-Position Magnetic Stirrer
product

Safety Instructions

| Warning!

  • Read carefully the operating instructions before use.
  • Ensure that only trained staff works with the instrument.

---|---
| Protective ground contact!

  • Make sure the socket is properly earthed (with protective ground contact) before use.

  • When working, wear the necessary personal protective equipment to avoid the risk of:

    • Burns caused by splashing and evaporation of liquids
    • Intoxication caused by release of toxic or flammable gases.
  • Set up the instrument on a spacious, stable, clean, non-slip, dry, and fireproof surface. Do not operate the instrument in explosive atmospheres, with hazardous substances, or under water.

  • Gradually increase the speed, reduce the speed if:

    • The stirring bar comes off due to a too high speed
    • The instrument is not running smoothly or the container moves on the base plate
  • Process pathogenic materials only in closed vessels.

  • Be aware of hazards due to:

    • Overfilling of media
    • Unsafe container
  • If the stirring bar contains PTFE, please note:

    • Elemental fluorine, trifluoride ion, and alkali metals will corrode PTFE. Halogen hydrocarbons expand PTFE at room temperature.
    • Molten alkali, alkaline earth metals or their solution, as well as elements on second and third column of the Periodic Table of elements will react with PTFE when temperature reaches 300 ~400 ºC
  • The instrument can only be disconnected from the main power supply by pulling out from the mains plug, not the cable.

  • The voltage stated on the label must correspond to the main power supply.

  • Do not cover the device.

  • The instrument may only be opened by experts.

  • Keep away from high magnetic fields.

  • Observe the minimum distances between the devices, between the device and the wall and above the assembly (min. 100 mm)

Proper Use

The instrument is designed for mixing liquids in schools, laboratories or factories.
This device is not suitable for use in residential areas or other constraints mentioned in Chapter 1.

Inspection

Unpacking
Unpack the equipment carefully and check for any damages that may have arisen during transportation. Please contact the manufacturer/supplier for technical support.
Note: If there is any apparent damage to the system, do not plug it into the power line.

Listing of Items
The package includes the following items:

Items Qty
Main unit 1
Power cable 1
Stirrer bar 2
User Manual 1

Control

Control elements

ibx 10 Positions Multi-Position Magnetic Stirrer fig 4 ibx 10 Positions Multi-Position Magnetic Stirrer fig
5 ibx 10 Positions Multi-Position
Magnetic Stirrer fig 6

Items Descriptions


Speed control knob

| The function “Stirring” is switched ON or OFF and adjusted with this knob.

Set the rated rotary speed within a safe range (between 0 and 1100 rpm).

To increase the speed, turn the knob clockwise. To stop the function, turn the knob all the way

counterclockwise.


Temperature control knob (only on H04X10)

| Set the rated temperature in the safe temperature range from room

temperature to 120℃. The function

“heating” is switched ON or OFF via the knob.(Heating model)

LED

“Power”

| While the device is ON, the LED power is lit.
Power Switch

I/O

| Switch ON or OFF the instrument.

Trial Run / Operation

  • Place the device on a stable and safe surface.
  • Make sure that the required operating voltage matches the power supply voltage.
  • Ensure that socket is earthed.
  • Plug in the power cable, ensure the power is on.
  • Ensure the speed control knob is at the lowest position.
  • Add the medium into the vessel using a suitable stirring bar.
  • Power ON the instrument by pressing the power switch I/O; the LED power will light up.
  • Put the vessel on one of the stirring points (see figure 2).
  • Set the rated stirring speed and start working. Turn the speed control knob to set the rated rotary speed in the safe speed range between 0 and 1100 rpm.
  • Observe the stirring bars.
  • Turn the temperature control knob to set the rated temperature in the safe limit from room temperature to 120℃ (only heating model).
  • Stop the stirring function by turning the speed control knob all the way counterclockwise.
  • Switch OFF the instrument by pressing the power switch I/O.

If these operations above cause no abnormalities, the device is ready to operate. Otherwise, the device may have been damaged during transportation, please contact manufacturer/supplier for technical support.
Warning: Forbid to transfer the vessel when the instrument working.

Faults

  • If a unit fault happens, please power OFF the instrument and then:
    • Switch the unit back ON.
    • The stirring function will continue to operate at the speed set before the fault took place.
  • Instruments cannot be powered ON.
    • Make sure the power cable is plugged in.
    • Check whether the fuse is broken or loose.
  • Stir speed cannot reach set point.
    • Excessive medium viscosity may cause an abnormal motor speed reduction.

If these faults are not resolved, please contact the manufacturer/supplier.

Maintenance and Cleaning

  • Proper maintenance can keep instruments working properly and lengthen their lifetime.
  • Do not spray cleanser onto the instrument when cleaning.
  • Unplug the power line when cleaning.
  • Only use recommended cleansers:
    Dyes| Isopropyl alcohol
    ---|---
    Construction materials| Water    containing    surfactants / Isopropyl alcohol
    Cosmetics| Water    containing    surfactants/ Isopropyl alcohol
    Foodstuffs| Water containing surfactants
    Fuels| Water containing surfactants
  • Before using any other cleaning or decontamination methods, verify with the manufacturer that such method will not harm the instrument. Wear the proper protective gloves when cleaning the instrument.
  • Wear proper protective gloves while cleaning the instrument.
  • If the device is to be shipped, it must be clean and packed in its original carton. Avoid contamination from hazardous substances.
  • The ceramic coating makes the instrument easier to maintain and more resistant to acids and bases. However, it makes it also more sensitive to extreme temperature fluctuations and to impact forces (risk of cracking of the coating).

Note

  • Electronic devices cannot be cleaned with cleanser.
  • If maintenance service is needed, the instrument must be cleaned in advance to avoid pollution from hazardous substances, and shipped in its original packing.
  • If the instrument will not be used for a long time, please switch off and place in a dry, clean stable location at room temperature and.

Associated Standards and Regulations

  • Manufacture in accordance with the following safety standards
    • EN 61010-1
    • UL 3101-1
    • CAN/CSA C22.2(1010-1)
    • EN 61010-2-10
  • Manufacture in accordance with the following EMC standards: EN 61326-1
  • Associated EU guidelines:
    • EMC-guidelines: 2004/108/CE
    • Instrument guidelines: 73/023/EWG

Technical data

Accessories

Please contact our company to order the following accessories available for these devices: magnetic stirring bars.

Service

If help is needed, you can always contact your dealer or Labbox via www.labbox.com Please, provide the customer service representative with the following information:

  • Serial number
  • Description of the problem
  • Your contact information

Warranty

This instrument is guaranteed to be free from defects in materials and workmanship under normal use and service, for a period of 24 months from the date of invoice. The warranty is extended only to the original purchaser. It shall not apply to any product or parts which have been damaged on account of improper installation, improper connections, misuse, accident or abnormal conditions of operation.
For claim under the warranty please contact your supplier.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals