Heiman 14604 Photoelectric Smoke Alarm User Manual

June 2, 2024
HEIMAN

14604 Photoelectric Smoke Alarm
User Manual

Standards tested to: EN14604:2005/AC:2008 DOP No.:20181215001
*Please read the user manual carefully before operation.
The guide picture is for reference only. Please in kind prevail.

Production Introduction

This product is a photoelectric smoke alarm, designed with ultra-low power Zigbee technology, featuring low power consumption, high security, and interoperability. It can detect the presence of smoke in real time. Once a smoke fire hazard is detected, the sensor’s red LED flashes quickly and a high-decibel alarm sounds, alerting your family in time. With the use of the smart gateway, remote alarm messages can be pushed to APP in real time.

Illustration’s

Heiman 14604 Photoelectric Smoke Alarm - Figure 1

Technical Parameters

  1. Operating Voltage : DC3V(CR123A/CR17335 lithium battery)
  2. Battery Life : 3 Years (According to actual use, Battery life may also be shortened)
  3. Alarm Indication red LED
  4. Sound Level : 5dB/3m
  5. Sensor Type : infrared photoelectric
  6. Networking : Zig bee
  7. Wireless Networking Distance 5100m (open area)
  8. Working Temperature : -10°C +50°C
  9. Working Humidity : 5 95%RH(no condensation)
  10. Dimension : Φ48 x H51mm

Device Adding

  • Open the APP and enter into gateway, then tap “+” to add smoke sensor according to the instructions.

Tips
Due to the APP upgrade and update, this guideline may be slightly different from the actual operation, please follow the instructions in the APP.

  • If networking failed, please move the device closer to the gateway and try again.
  • Please add the device to the gateway first, and then install and fix it.

Heiman 14604 Photoelectric Smoke Alarm - Figure 3

  • Add device: press and hold the networking button for 2 seconds, until the green LED flashes quickly, then the device will be shown in the APP.
  • Delete device: press and hold the networking button for 5 seconds, until the green LED flashes slowly, indicating the device is deleted from gateway.

Light Status

State LED Sound Alarm
Standby Red LED flashes once every 53 seconds None
Test Red LED flashes quickly rapid”Di-Di-Di”
Alarm Red LED flashes quickly rapid”Di-Di-Di’
Hush Red LED flashes once every 10 seconds None

Low
Battery| Red LED flashes once every 53 seconds| “Di” every 53 seconds
Fault| Red flashes twice every 53 seconds| “Di-Di” every 53 seconds

Function Description

  1. Alarm status: When the smoke sensor detects that the smoke concentration exceeds the limit, the red LED flashes and the buzzer sound alarm.
  2. Fault condition: When the internal circuit of the smoke sensor fails, the red LED flashes twice every 53 seconds, and the buzzer beeps two times.
  3. Mute state: When cooking or vapor causes the smoke sensor to alarm, press the mute button to silence the sensor. When mute, the buzzer stops sounding alarm. The red LED flashes once every 10 seconds and the mute time is 90 seconds. After 90 seconds, it automatically returns to normal detection.
  4. Low battery: When the battery voltage is lower than the normal working voltage, the red LED flashes once every 53 seconds, and the buzzer beeps once.

Installation Precautions

  1. This product is for indoor use only.
  2. Do not install the sensor in a location with high temperature and humidity, or with large oily fume. Keep the air around the sensor clean.
  3. Avoid a lot of paint, thinners, etc. that produce colloidal aerosol near the sensor, so as not to affect the normal monitoring of the sensor.
  4. This product is a household smoke sensor, which can give audible and visual warning when fire occurs, but it can not extinguish the fire.
  5. Smoke, heat, and burning products arising to ceils will spread The installation of smoke sensors in the center of the ceiling is the preferred location. Please maintain a distance of at least 30cm from the fixture or omament. Keep at least 15cm away from walls and corners. If the hall exceeds 12 meters, it should be installed at both ends of the hall.

Product Installation

  1. Please put gateway into the center of alarms.
  2. Please shorten the distance between gateway and alarms.
  3. Please reduce barriers between gateway and alarms.
  4. Avoid installing in places with high noise or high frequency interference, or places near metal, air conditioner, heater devices, current circuit breaker control box.
  5. Building materials with metal net or metal bar may reduce the wireless transmission distance, like reinforced concrete wall.
  6. Damping of the signal makes direct ratio with barrier, if the materials of the barrier is homogeneous.
  7. Select a suitable location and attach the sensor bracket to the ceiling with 3M tape or screws.
    Then rotate the sensor clockwise into the mounting bracket.

Recommended Installation Location

Heiman 14604 Photoelectric Smoke Alarm - Figure 4

installation Illustration

  • Rotate the bracket anticlockwise out from the installation base.
  • Step 1: remove the double-sided tape and stick alarm on wall or ceiling.
  • Step 2: fixed the bracket into ceiling by using screws.

Installation with double-sided adhesive should pay attention to as follows:

  1. Make sure the installation surface is smooth. flat, stable, dry and clean.
  2. After installation, regularly check whether the product is attached firmly to the installation surface.
    Heiman 14604 Photoelectric Smoke Alarm - Figure 7
  • Remove the battery insulating strip to electrify the alarm, and rotate alarm into bracket clockwise.
  • To engage tamper-resist feature, insert the locking pin into the hole on edge of smoke alarm device after the device is properly positioned.

Mute And Self-test

Please make sure that there is no real danger of fire when mute the alarm, do not block the smoke alarm from alarming. When false alarm happens, press hush button to mute the alarm.
Press and hold the test button for 3 seconds, until the smoke alarm sounds alarm. Recommend to test the smoke alarm monthly. Prohibit to test the alarm by using a fire.

Battery Replacement

  • When the alarm device indicates low battery. please replace the battery in time to avoid affecting the normal use of the product.
  • Correctly replace the battery according to the positive and negative poles of the battery, pay attention to environmental protection, and properly dispose of used batteries.

Maintenance

  1. Press test button to test alarm devices weekly, after devices are put into use. Please inspect the alarm device or return to factory if any faults happened ( buzzer does not  make sound, LED does not turn on).
  2. Battery can use around 3 years under normal condition, high temperature, high humidity or other poor condition may shorten battery life span.
  3. Please change the same battery timely when low power indication occurs.
  4. Make sure alarm devices in good condition, and take measures for dust proof, damp proof and corrosion proof etc.
  5. Do not dismantle alarm devices privately if any problems of alarm devices happened.
  6. Recommend to change new battery after real fire alarm happened.

Symptom Analysis

Symptom Reason Remedy
False alarm Serious pollution in the labyrinth Return to factory for

maintenance
Large dust or vapour| Clean dust or vapour
Circuit failure| Return to factory for maintenance
Short “Di-Di”| Low battery| Change same battery
Circuit failure| Return to factory for maintenance
Buzzer do not alarm or small sound| Low battery| Change same battery
Press test button but no alarm| Battery is not installed or reversed| Reinstall the battery, pay attention to the correct polarity
Low battery| Change same battery
Circuit failure| Return to factory for maintenance

Statement

  1. The information in the user manual is for reference only and does not constitute any form of commitment.
  2. Without the written permission of the manufacturer, any individual or organization shall not extract or copy part or all of the contents of this user manual, and shall not spread it in any form.
  3. As the technology is constantly updated, the manufacturer reserves the right to modify the user manual without prior notice. If the user manual and the actual operations is inconsistent, the final interpretation is reserved to the manufacturer herein.

Shenzhen Heiman Technology Co., Ltd
URL: www.heimantech.com Address:101, No.4 Dafu Industrial Park.
Kukeng Community, Guanlan Street, Longhua District. Shenzhen, China
Hot Line:+86-755-84193920 +86-755-84193951

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals