HEIMAN HM-807DWP Digital Passive Infrared Motion Detector Instruction Manual
- June 5, 2024
- HEIMAN
Table of Contents
M117-1Ever1.0
Digital Passive Infrared Motion Detector Manual
PRODUCT INTRODUCTION
This product is a digital infrared motion detector with high stability. It
adopts dual-sensor signal processing technology and provides super high
detection and anti-false alarm performance, and MCU processing ensures its
reliability from the design basis. Any intruder passing through the detection
area, the detector will automatically detect the movements of the human body
and pets. If Any dynamic movement, it will send the alarm signal to the
mainframe. This product is suitable for safety in residential areas, villas,
factories, shopping malls, warehouses, and office buildings, etc.
**PRODUCT PROFILE
**
TECHNICAL SPECIFICATIONS – INSTALLATION HINTS
Working voltage: DC 9-24V
Consumption Current: 18mA
Detecting distance: 12 m
Detecting Angle: 110 degrees
Detecting Speed:0.3m/s~ 3m/s
PIR sensitivity adjustment availability
Adjustable immunity
Self-Testing Time: 60s
Alarm Delay Time: 3s/30s optional
Alarm Indication: Red LED with on/off availability
Sensor: Double element pyroelectric infrared sensor
Operating Temperature: -10°C ~ +50°C
Wired connection feeding 12 volts
Environment Humidity: Max 95% RH (no congelation)
Anti-RF interference: 1|OMHZ~1GHz 20v/m
Installation Mode: Wall or corner mount
Alarm Output: NC/NO optional, contact rated at DC28V 100mA
Tamper Output: NC, contact rated at DC28V 100mA I
nstall height: recommend 2m|
---|---
FEATURES
- EN 50130 certified
- MCU control, high efficience of anti-false alarm
- Dual Sensor technology, real pet-immunity
- Immunity(25kgs)
- Dual-mode Temperature Compensation
- Dynamic Thresholds Adjustment Technology
- Bipolar Pulse Count Adjustable
- Anti White Light Interference, Anti RF Interference
- Fresnel! Lens
- Alarm Output N.C./N.O. Optional
- Alarm Delay Time Optional (3s/30s)
- SMT Manufacture Technology, Stabler Performance Yellow wire: tamper output
- Wall-mounted
INSTALLATION CONDITIONS
1. For good pet immunity performance, the installation height is recommended
not lower than 2m. Mount the detector flat on a wall or in a corner. Do not
angle it downwards.
2. Avoid placing the detector the outsides, near an air-conditioner or a heat
source, in direct sunlight, beneath a rotating object and car fluttering
curtains. Do not place objects about 1.8m high in front of the detector, that
a pet can jump onto and pet immunity will be reduced.
3. Surface of installation should be firm with no vibration.
4. Mount the detector where an intruder passes easily.
WIRING INSTRUCTIONS
Red wire: positive DC power
Black wire: negative DC power
Yellow wire: tamper output
White wire: alarm output
INSTALLATION STEPS
- Install the detector in a suitable position. Cut off the thin plastic in the bracket if the open wire is installed.
- Connect the power wire and signal wire as per wiring instructions.
- Screw the detector into the bracket (the click sound sayswell-installed). Adjust the install angle as needed.
INSTALLATION ILLUSTRATIONS
OPERATING INSTRUCTION
- Function setting _ refers to figure three
- Pulse jumper: Adjust the pulse count to change the sensitivity and anti-RF interference ability. Short 1&2: Class | pulse, high sensitivity, and strong anti-RF interference adapt to the general environment. Short 2&3: Class 2 pulse, low sensitivity, and stronger anti-RF interference adapt to the environment with serious RF interference.
The factory setting is Short 1&2 (class | pulse).
-
Relay jumper: Choose N.C./N.O. to set the status of alarm output.
You can choose the different outputs in accordance with the alarm mainframe. Short 1&2: N.O. ( normally open) Short 2&3: N.C. (normally closed)
The factory setting is Short 2&3 N.C.(normally closed) -
Delay jumper Alarm delay time is the duration of the alarm indicator before the alarm.Short 1&2: delay 3 sec.Short 2&3: delay 30 sec. The factory setting is Short 1&2, delay 3 sec.
-
LED jumper
for setting LED ON/OFF, no effect to the detect normal work.
LED can be shut off for the concealment of the detector aftertest -
Product testing
Turn on the power and the indicator. The detector comes into auto-check status for about 60 sec. The LED indicator turns off and the detector comes into normal detecting status. The tester should walk parallel with the wall- installed detector in the testing area. LED indicator turns on, which indicates the detector is in alarm status.
NOTICE
- Please install and use the detector as the manual instructed. Any detector failure, please inform the management center or our company after-sales service center for repair.
- The product can reduce accidents, but cannot ensure any risk at all. For your safety, in addition to the proper use of this product, remain vigilant in your daily life and strengthen security prevention consciousness.
- 1[n order to guarantee it can work well, the power should be kept to supply, and conducted walking tests periodically. Once a week is suggested.
DETECTING AREA VIEW
Documents / Resources
|
HEIMAN HM-807DWP Digital Passive Infrared Motion
Detector
[pdf] Instruction Manual
HM-807DWP, Digital Passive Infrared Motion Detector, HM-807DWP Digital Passive
Infrared Motion Detector
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>