Heiman 601010842-HS1CA Smart Home Carbon Monoxide Detector User Manual
- June 5, 2024
- HEIMAN
Table of Contents
Heiman 601010842-HS1CA Smart Home Carbon Monoxide Detector
Product Introduction
This product is a smart carbon monoxide sensor, adopts super low power consumption Z-Wave wireless networking technology. used for detecting cartbon monoxide. Sensor adopts high performance electrochemical sensor, support sound and flash alarm, It has high stability, super low power consumption, little senstivity drift and many other features Free installation design,support instant bonding.
Technical Data
-
Working Voltage: DC3v
(CR17335/CR123A Lithium Battery) -
Alarm Sound: 285dB/1m
-
Alarm Sensitivity: 30ppm 120 mins alarm
- 50ppm 60-90 mins alarm
- 100ppm 10-40 mins alarm
- 300ppm 3 mins alarm
-
Networking: Z-Wave
-
Wireless Networking Distance: s 70m(open area)
-
Working Temperature: -10’C+50C
-
Working Humidity: s 95%RH
-
Dimension: 60 60 49.2 mm
Tips
-
This product can not be used for detecting natural gas
(methane), propane, butane and other combustible gas. -
Clean once a month, users may use household vacuum cleaner and soft brush when cleaning.
-
Do not use cleanser or solvent wipe sensors, please avoid spraying air freshener, hair spray, oil paint or other aerosol near sensors.
-
Effective working life span is 5 years, suggest replace every 5 years no matter there is fault or not. (Battery life span is 3 years).
-
Please be attention when an alarm happens. Shut-off valves immediately, opening the window, make sure indoor airiness. Besides using sensors correctly, users should strengthen the consciousness of fire protection.
Installation Instruction
-
Install the sensor in the bedroom and living area or anywhere CO may leak, make sure each sleeping area can hear sound alam when choose installation position.
-
Avoid suppressing or falling down sensors, keep sensors away from humid, high voltage, strong magnetic and children
-
Do not suggest install sensors in garage, kitchen, boiler and places where sensor may false alarm. Do not install in dirty, dusty or greasy places, oily, dust or household chemicals may damage internal sensor, and make sensor
can not work normally. -
Sensors can support wall-mounted or placed on the table, household and travel essential.
Installation Drawing
- To increase safety factors in single-layerhouse, suggest to install at least a sensor in each bedroom and install a sensor at 6m from chimney and gas fixture.
- To increase safety factors in multi-Hayer house, suggest to install at least a sensor in each bedroom, install at least one sensor in basement. Please install a sensor at 6m from chimney and gas fixture.
Installation Step1
- Anticlockwise rotating the bracket out from the installation base, then remove the battery insulating strip to make detector on power.
Installation Step2
- Click “Add Device” on the APP interface, and enter the networking mode.
Installation Step3
- Connecting network: According to the APP tip, press the device networking button for 3 times in 1.5 seconds, then the green LED flashes quickly (connecting network within 30 seconds), and networking succeed will be displayed on app in terface.
- Disconnecting network: Click the “delete device” button on APP, then quick press networking button for 3 times in 1.5 seconds, green LED flashes for 6 times, disconnecting network succeed.
Installation Step4
- Step 1: remove the double-sided adhesive and stick alarm into ceiling.
- Step 2: fied the bracket into ceiling using screws.
LED Status
Battery replacement
- Please replace battery correctly, following the battery positive and negative electrode.
Troubleshooting
Please take the following advice for reference if sensors can not work normally:
- Replace the battery in time, if voltage too low and reach effective life span. (Check table 1 for state reference).
- Please clean the sensor if the fault resulted from dust or oil stain (Check table 1 for state reference).
- Make sure sensors screw into the base correctly.
Test
- Press test button on the product for 3 seconds,shows in above picture, till alarm happens ( check table 1 for state reference).
- Suggest test sensor at least once a week. Please pay attention once alarm happens.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>