inakustik Referenz AC-4500 Power Station User Manual

June 2, 2024
inakustik

REFERENZ AC-4500
BEDIENUNGSANLEITUNG
USER MANUAL

SAFETY INSTRUCTIONS

GENERAL
Thank you for using this product. Read, observe and adhere to the following safety instructions. Please keep the operating manual. Observe all the warning notices on the components and in the operating manual.
PROPER USE
The device is designed solely for operation on audio and video equipment in private environments and solely for indoor use. Connect it as specified in the operating instructions. Also observe the operating instructions of the devices to be connected. Only use accessories which have been recommended by the manufacturer. The device may only be operated in the specified voltage range!
SAFETY INSTRUCTIONS
Do not expose the device to high levels of humidity under any circumstances. Only operate the device on places which does not have a high level of relative humidity and is free of moisture. Moisture can bypass the electrical insulation and pose a lethal danger. Do not position the equipment near sources of heat, heaters, ovens or other heat-producing devices. Note that electric devices may heat up during operation.
Extreme temperature fluctuations, humidity and extended exposure to light can damage the cable and alter their appearance. Make sure that no foreign objects or liquids enter the device.
Make sure that the rack or board can safely support the weight of the device.
All cables must be placed in such a way that there is no danger to damage them (e.g. being stepped on, sharp edges etc.). The cable must not be bended, pulled or twisted. Never remove cables by pulling the cable; instead, always hold the plug when disconnecting.
Pay attention to the accuracy and correct fit of the plugs or connectors. Do not use high force to plug the connectors into the device sockets.
In stand-by mode the devices connected to the Power Station are disconnected from the mains on all poles (phase and neutral conductor).
However, the absence of voltage is only ensured when the power plug is pulled out.
Devices which are connected to the mains consume electricity and are always a potential fire hazard. Therefore it is recommended to completely disconnect the power station from the mains during absence!
FUSE
A fuse of 20A as part of the electrical installation of the building is assumed.
PROTECTIVE GROUNDING CONDUCTOR
The device corresponds to protection class 1, which requires proper protective earthing. The electrical safety of the device is therefore only guaranteed if the protective grounding conductor of the device is connected to the protective grounding conductor of the electrical installation of the building. In order to avoid property damage and personal injury (e.g. electric shock) due to a missing or interrupted protective earthing conductor, this basic safety requirement must be met. Only use power cables with a protective conductor and sockets with a protective contact. If in doubt, have the house installation checked by a qualified electrician.
POWER DISCONNECTION
The power cord must be able to be unplugged for safe disconnection from the mains. For this purpose, the power plug must be freely accessible in order to disconnect the device quickly from the mains in case of a failure.
MAINTENANCE
Maintenance on the product may only be performed by persons qualified to do so. Maintenance is necessary in all cases of damage, i.e. in the case of damaged cables and plugs, as well as after liquid spills or objects falling on the device, devices falling down, foreign objects entering the device, exposure of device to rain or humidity, or other influences impairing the functioning of the component.
LOOKING AFTER THE PRODUCT
Disconnect the components from the power supply before cleaning them Always clean the components with a soft, dry and lint-free cloth, or with a brush. Do not under any circumstances use scouring powder, alcohol, benzine, furniture polish or similar substances.
POWER CABLES / POWER BARS
When using multiple power boards and extension cables, pay special attention to the DIN VDE 0100 part 420, para. 4.1 (risk of fire in electrical installations). Furthermore, the VDE 0100-410:2007-06 also requires short breaks of 0.4 s for the TN system. The temperature of the cable may rise in such cases to the point of causing a fire.  here fore, the following applies to ALL power boards: Do not connect them in a row and do not use if covered! For power bars with two-pin relay, the units connected to the switched sockets will be reliably and 2-pin (also known as all-pin) disconnected from the mains. However, the absence of voltage in the unit is only ensured when the mains plug is disconnected.

DESCRIPTION

Video and audio quality starts at the mains. Unfortunately, the power grid is usually heavily loaded and enriched with a wide range of interferences. Many especially digital equipment, switched-mode power supplies, car charging stations and photovoltaic systems generate strong distortions on the network, which cause problems for the connected audio devices. The power supplies and audio circuits in the audio devices are stressed, but can only compensate parts of this interference. The rest influences the audio signal and covers the sound of the HiFi System like a veil.
The Referenz AC-4500 Power Station includes, among other things, high-quality mains current filters that are specially designed for high-end applications. Specially developed
filter networks divert relevant distortions to ground. In this way, fine facets of the music keep alive and can be discovered more clearly.
The heart of the Reference AC-4500 Power Station also includes a powerful DC suppression that filters direct current components from the mains. As a result, the connected devices are supplied with “symmetrically” power, which particular protects toroidal transformers from becoming magnetically saturated. This prevents the familiar transformer hum and improves efficiency as well as the sound performance

FEATURES

  • High Effective Filters
  • DC-Blocker
  • High Quality Sockets
  • Pure Copper Power Bars
  • Metal Housing
  • All Pole Power Disconnecting
  • Over Voltage Protection
  • Made in Germany

inakustik Referenz AC-4500 Power Station - 1

INSTALLATION

After unpacking the Power Station, place it in the desired location. Please note the safety instructions. Connect the devices to the AC-4500 according to the respective operating instructions.
If you want to connect your system in the correct phase, the markings on the sockets will help you. Ask your specialist dealer about this. Finally, connect the Power Station to the mains.
After checking all connections switch on the Power Station on the front.

EXAMPLES OF CONNECTIONS

FILTERBOARD ANALOG
SOCKETS TYP 1

  • Power Amp Tube
  • Class A/B Power Amp
  • Integrated Ample Tube
  • Integrated Amp Class A/B
  • Preamp
  • Phono Preamp
  • Turntable
  • Tape Recorder
  • etc.

FILTERBOARD DIGITAL
SOCKETS TYP 2

  • Class D Power Amp
  • Class D Integrated Amp
  • DAC
  • Streaming Player
  • CD Player
  • CD Drive
  • TV
  • Network Components
  • etc.

OPERATION

Use the button on the front of the AC-4500 to turn the power outlets on and off. When the Power Station is switched off, the phase and the neutral conductor of the connected devices are disconnected from the mains (all-pole). The LED above the ON / OFF button indicates the operating status. If the LED lights up red, the sockets are switched off. If the LED lights up blue, the sockets are switched on.
ATTENTION: It is essential to follow the operating instructions for the connected devices! Some devices have to be shut down like a computer BEFORE being disconnected from the mains in order to prevent data losses. This is particular important when switching off the AC-4500!

SCOPE OF DELIVERY

  • Power Station Referenz AC-4500
  • Power Cord
  • Manual

TECHNICAL DATA

  • Amount of outlets: 6
  • Power input: IEC C-20 Dose
  • Operating Voltage: 230VAC / 50-60Hz
  • Maximum Operating Current: 16 Ampere (Summary)
  • Maximum Power Load: 3680 VA
  • (NEMAN-15P: Maximum Value 125VAC / 15 Ampere)
  • Protection class I
  • Dimensions: ca. 450 x 386 x 122mm
  • Weight: approx 15 kg (Full) | 13,5 kg (Mid) | 12 kg (Small)

DISPOSAL

According to WEEE directive 2012/19/EU old or defective devices that are labeled with a crossed-out rubbish bin may not be disposed of with conventional household waste. They must be handed in at local recycling centres in accordance with the applicable national legislation. Proper disposal helps to conserve resources and protect the
environment.
OUR CABLE RECOMMENDATION
The Referenz AIR Mains Cables –
Visit our Website: www.in-akustik.de

inakustik Referenz AC-4500 Power Station - 4

inakustik Referenz AC-4500 Power Station - 5 Typ: Referenz Power Station AC-4500
Item-No: 007645xx

in-akustik GmbH & Co. KG
Untermatten 12-14
79282 Ballrechten-Dottingen
Germany
Tel.: +49 (0) 7634 5610-70
Fax: +49 (0) 7634 5610-80
E-Mail: info@in-akustik.de
Web: www.in-akustik.de
MADE IN GERMANY

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals