SAFETY INSTRUCTIONS
Thank you for using this product. Read, observe and adhere to the following safety instructions. Please keep the operating manual. Observe all the warning notices on the components and in the operating manual.
PROPER USE
The device is designed solely for operation on audio and video equipment in private environments and solely for indoor use. Connect it as speci-fied in the operating instructions. Also observe the operating instructions of the devices to be connected. Only use accessories which have been recommended by the manufacturer. The device may only be operated in the specified voltage range!
SAFETY INSTRUCTIONS
Do not expose the device to high levels of humidity under any circumstances.
Only operate the device on places which does not have a high level of relative
humidity and is free of moisture. Moisture can bypass the electrical
insulation and pose a lethal danger. Do not position the equipment near
sources of heat, heaters, ovens or other heat-producing devices. Note that
electric devices may heat up during operation. Extreme tempera-ture
fluctuations, humidity and extended exposure to light can damage the cable and
alter their appearance. Make sure that no foreign objects or liquids enter the
device. Make sure that the rack or board can safely support the weight of the
device. All cables must be placed in such a way that there is no danger to
damage them (e.g. being stepped on, sharp edges etc.). The cable must not be
bended, pulled or twisted. Never remove cables by pulling the cable; instead,
always hold the plug when disconnecting. Pay attention to the accuracy and
correct fit of the plugs or connectors. Do not use high force to plug the
connectors into the device sockets.
In stand-by mode the devices connected to the Power Station are disconnected
from the mains on all poles (phase and neutral conductor). Ho-wever, the
absence of voltage is only ensured when the power plug is pulled out. Devices
which are connected to the mains consume electricity and are always a
potential fire hazard. Therefore it is recommended to completely disconnect
the power station from the mains during absence!
FUSE
A fuse of 20A as part of the electrical installation of the building is assumed.
PROTECTIVE GROUNDING CONDUCTOR
The device corresponds to protection class 1, which requires proper protective earthing. The electrical safety of the device is therefore only gua-ranteed if the protective grounding conductor of the device is connected to the protective grounding conductor of the electrical installation of the building. In order to avoid property damage and personal injury (e.g. electric shock) due to a missing or interrupted protective earthing conductor, this basic safety requirement must be met. Only use power cables with a protective conductor and sockets with a protective contact. If in doubt, have the house installation checked by a qualified electrician.
POWER DISCONNECTION
The power cord must be able to be unplugged for safe disconnection from the mains. For this purpose, the power plug must be freely accessible in order to disconnect the device quickly from the mains in case of a failure.
MAINTENANCE
Maintenance on the product may only be performed by persons qualified to do so. Maintenance is necessary in all cases of damage, i.e. in the case of damaged cables and plugs, as well as after liquid spills or objects falling on the device, devices falling down, foreign objects entering the device, exposure of device to rain or humidity, or other influences impairing the functioning of the component.
LOOKING AFTER THE PRODUCT
Disconnect the components from the power supply before cleaning them Always clean the components with a soft, dry and lint-free cloth, or with a brush. Do not under any circumstances use scouring powder, alcohol, benzine, furniture polish or similar substances.
POWER CABLES / POWER BARS
When using multiple power boards and extension cables, pay special attention
to the DIN VDE 0100 part 420, para. 4.1 (risk of fire in electrical
installations). Furthermore, the VDE 0100-410:2007-06 also requires short
breaks of 0.4 s for the TN system. The temperature of the cable may rise in
such cases to the point of causing a fire. Therefore, the following applies to
ALL power boards: Do not connect them in a row and do not use if covered!
For power bars with two-pin relay, the units connected to the switched sockets
will be reliably and 2-pin (also known as all-pin) disconnected from the
mains. However, the absence of voltage in the unit is only ensured when the
mains plug is disconnected.
DESCRIPTION
Video and audio quality starts at the mains. Unfortunately, the power grid is
usually heavily loaded and enriched with a wide range of interferen-ces. Many
especially digital equipment, switched-mode power supplies, car charging
stations and photovoltaic systems generate strong distortions on the network,
which cause problems for the connected audio devices. The power supplies and
audio circuits in the audio devices are stressed, but can only compensate
parts of this interference. The rest influences the audio signal and covers
the sound of the HiFi System like a veil.
The Referenz AC-3502 Power Station includes, among other things, high-quality
mains current filters that are specially designed for high-end applications.
Specially developed filter networks divert relevant distortions to ground. In
this way, fine facets of the music keep alive and can be discovered more
clearly.
FEATURES
- High Effective Filters
- Symmetrical Star Power Distribution
- High Quality Sockets
- High Current Mains Connector IEC C-20 Sockets
- All Pole Power Disconnecting
- Over Voltage Protection
- Brusched Aluminum Front
- Metal Housing
- Made in Germany
INSTALLATION
After unpacking the Power Station, place it in the desired location. Please note the safety instructions. Connect the devices to the AC-3502 accor-ding to the respective operating instructions. If you want to connect your system in the correct phase, the markings on the sockets will help you. Ask your specialist dealer about this. Finally, connect the Power Station to the mains. After checking all connections switch on the Power Station on the front. BEFORE being disconnected from the mains in order to prevent data losses. This is particular important when switching off the AC-3502!
OPERATION
Use the button on the front of the AC-3502 to turn the power outlets on and
off. When the Power Station is switched off, the phase and the neutral
conductor of the connected devices are disconnected from the mains (all-pole).
The LED above the ON / OFF button indicates the operating status. If the LED
lights up red, the sockets are switched off. If the LED lights up blue, the
sockets are switched on.
ATTENTION: It is essential to follow the operating instructions for the
connected devices! Some devices have to be shut down like a computer BEFORE
being disconnected from the mains in order to prevent data losses. This is
particular important when switching off the AC-3502!
SCOPE OF DELIVERY
- Power Station Referenz AC-3502
- Power Cord
- Manual
TECHNICAL DATA
- Amount of outlets: 6
- Power input: IEC C-20 Dose
- Protection class I
- Dimensions: ca. 450 x 386 x 122mm
- Weight: ca. 10 kg
SCHUKO
- Operating Voltage SCHUKO: 230VAC / 50-60Hz
- Maximum Operating Current: 16 Ampere (Summary)
- Maximum Power Load: 3680 Watt (230VAC / 16 Ampere)
NEMA-15P
- Operating Voltage: 125VAC / 50-60Hz
- Maximum Operating Current: 15 Ampere (Summary)
- Maximum Power Load: 1875 Watt (125VAC / 15 Ampere)
BS1363
- Operating Voltage: 230VAC / 50-60Hz
- Maximum Operating Current: 13 Ampere (Summary)
- Maximum Power Load: 2990 Watt (230VAC / 13 Ampere)
DISPOSAL
According to WEEE directive 2012/19/EU old or defective devices that are labeled with a crossed-out rubbish bin may not be disposed of with conventional household waste. They must be handed in at local recycling centres in accordance with the applicable national legislation. Proper disposal helps to conserve resources and protect the environment.
MISC
Indication without guarantee. All product images similar. We reserve the
right to make changes.
IMPORTANT REMARK
Please also refer to further remark about this product on our homepage www
.in-akustik.com!
This product is NOT intended for the US or any other US territory and may NOT
be operated in these countries!
Typ: Referenz Power Station AC-3502
Item-No.: 007635027 / 007635027US / 007635027UK / 00763502x / 00763502xUS /
00763502xUK
in-akustik GmbH & Co. KG
Untermatten 12-14
79282 Ballrechten-Dottingen
Germany
Tel.: +49 (0) 7634 5610-70
Fax: +49 (0) 7634 5610-80
Email: info@in-akustik.de
Web: www.in-akustik.de