VIZULO 66712 Shell Basic LED Luminaire Instruction Manual
- June 3, 2024
- VIZULO
Table of Contents
66712 Shell Basic LED Luminaire
Instruction Manual 20-05-2022 SIA VIZULO
Laucu Lejas, Iecava, Latvia, LV-3913
www.vizulo.com
VIZULO Shell Basic LED luminaire
Mounting instruction
Dimensions Mounting hole location
Netto Weight
WARNING!
- Do not touch LED modules!
- Do not put any tools or other items on LED modules!
- In case any LED is physically damaged (example shown below) the warranty is void.
Install LED luminaire only in a clean room using gloves!
Diffuser cover may accumulate small electrostatic charges that makes it
susceptible to dust and other small particles;
It should only be cleaned using dry microfiber cloth or compressed air
duster.
User manual of microwave motion sensor
Settings:
-
Sensitivity Sensitivity can be adjusted by selecting the combination on the DIP switches for different applications.
-
Hold-time Hold-time refers to the time period that the light remains 100% on if no more movement is detected.
-
Daylight sensor Different daylight threshold can be preset on DIP switches. Light will always turn on upon movement if daylight sensor is disabled.
Settings (Remote Control)
Permanent ON/OFF function
Press button “ON/OFF” to select permanent ON or permanent OFF mode.
-
Press button “AUTO”, “RESET” to quit this mode. The mode will change to AUTO Mode after power failure.
Reset Settings
Press button “RESET”, all settings go back to default settings.
Shift Button
Press button “Shift”, the LED on the top left corner is on to indicate mode selection.
All values / settings in RED are valid for 20 seconds.
AUTO mode
Press button “AUTO” to initiate automatic mode. The sensor starts working and all
settings remain as before the light is switched ON/OFF.
SEMI-AUTO mode
First press button “Shift” then “SEMI-AUTO” to initiate semi-auto mode. The fixture is manually on by push-switch and automatically off in this mode.
Power output
Press the buttons to select light output at 80% (at initial 10,000 hours) or 100%.
Note: “Sensor off” and “Twilight” functions are disabled.
Brightness +/-
Press the buttons to adjust the light brightness during hold-time.
Scene program – 1-key commissioning- Press button “Start” to program.
- Select the buttons in “Detection range”, “Daylight threshold”, “Hold-time”, “Stand-by time”, “Stand-by dimming level” to set all parameters.
- Press button “Memory” to save all the settings programmed in the remote control.
- Press button “Apply” to set the settings to each sensor unit(s).
For example, to set detection range 100%, daylight threshold Disable, hold-
time 5min, stand-by time +∞, stand-by dimming level 30%, the steps should be:
Press button “Start”, button ”100%”, “Disable”, “Shift”, “5min”, “Shift”,
“+∞”, “30%”, “Memory”. By pointing to the sensor unit(s) and pressing “Apply”,
all settings are passed on the sensor(s).
Detection range (valid for master only)
Press buttons in zone “Detection range” to set detection range at 100% / 75% /
50% / 10%.
Daylight threshold
Press buttons in zone “ Daylight threshold” to set daylight sensor at 2Lux /
10Lux /50Lux / 100Lux / 300Lux / 500Lux / Disable.
Note:
- To set daylight sensor at 100Lux / 300Lux / 500Lux, press “Shift” button first
- These buttons are invalid for HCO34RF.
Ambient daylight threshold
- Press button “Shift”, the red LED starts to flash.
- Press button “Ambient”, the surrounding lux level is sampled and set as the new daylight threshold.
Hold-time
Press buttons in zone “hold-time” to set the hold-time at 2s /30s/ 1min /5min
/10min / 15min / 20min / 30min.
Note:
- To set hold-time at 30s / Smin / 15min / 30min, press “Shift” button first
- 2s is for testing purpose only, stand-by period and daylight sensor settings are disabled in this mode.
*To exit from Test mode, press button “RESET” or any button in “Hold-time”.
Stand-by time (corridor function)
Press buttons in zone “stand-by time” to set the stand-by period at 0s / 10s /
1min / 5min / 10min / 30min / 1h / +∞.
Note: “Os” means on/off control; “4-00” means bi-level control, if daylight
threshold is disabled or natural light is insufficient, the fixture is 100% on
when there is motion detected, and remains at the stand-by dimming level after
motion hold-time.
Stand-by dimming level
Press the button in zone “stand-by dimming level” to set the stand-by dimming
level at 10%/ 20%/ 30%/ 50%.
Auto-configuration function
All buttons in this zone are disabled.
Dual tech & RF mode
“HF”,”PIR”, “HF+PIR”, “HF/PIR” are disabled.
For RF grouping via remote control, please refer to steps below:
RF grouping
Short press “Learn/Erase” button on RC to activate pairing mode, and the
receiver unit starts to beep once every second for 3min.
Note: the unit can only pair up to 30 units.
Short press “Transmit” button on RC, the commander unit (master unit) beeps
one time to send the transmission signal.
Upon receiving the transmission signal, the receiver unit (slave unit) rapidly
beeps 3 times in 1s to indicate the success of pairing. Repeat this step to
pair more units.
One more short press on “Learn/Erase” button to the receiver unit to complete
the pairing process, the receiver unit will quit the pairing mode.
Note: Press button RX100%, the light on receiver unit is 100% on upon
receiving RF on signal; Press “RX STBY%” button, the light(s) goes to preset
stand-by dimming level directly.
Erase:
Long press “Learn/Erase” button for 3s to the sensor unit. The beeper beeps
rapidly for about 5s. All commands received before are erased.
Master /Salve configuration
Tridonic LED driver
MCB/Inrush current table
Power range| Dimming| In-rush current (peak/duration)| B10A| B13A| B16A| B20A|
C10A| C13A| C16A| C20A
7 – 10 W| DALI| 15 A (243µs)| 24| 31| 38| 48| 40| 56| 64| 80
Non dimmable| 17A (231 µs)| 23| 30| 37| 47| 38| 50| 61| 78
11- 17 W| DALI| 18 A (140 µs)| 22| 30| 36| 46| 36| 50| 60| 76
Non dimmable| 15 A (204 µs)| 25| 33| 40| 50| 41| 55| 66| 83
18 – 28 W| DALI| 25 A (141 µs)| 19| 24| 31| 40| 31| 40| 51| 66
Non dimmable| 16A (229 µs)| 25| 32| 39| 50| 41| 53| 65| 83
OSRAM LED driver
MCB/Inrush current table
Power range| Dimming| In-rush current (peak/duration)| B10A| B13A| B16A| B20A|
C10A| C13A| C16A| C20A
7 – 15 W| DALI| 8 A (150 µs)| 38| | 60| | | | |
Non dimmable| 5 A (45 µs)| 82| | 130| | | | |
16 – 28 W| DALI| 13 A (225 µs)| 20| | 30| | | | |
Non dimmable| 20A (50 µs)| 50| | 80| | | | |
User manual of PIR motion sensor
Settings (Remote Control HRC-12, for HIR02/RC12 & HIR04/RC12 & SAM13/RC12)
Permanent ON/OFF function
Press button “ON/OFF” to select permanent ON or permanent OFF mode.
- Press button “AUTO”, “RESET” or “Ambient” to quit this mode.
The mode will change to AUTO Mode after power failure.
Reset Settings
Press button “RESET”, all settings go back to default values.
Sensor mode
Press “Auto Mode” button, the sensor starts to function and all settings remain the same as the latest status before the light is switched on/off.
SEMI-AUTO mode
Press button “SEMI-AUTO” to initiate semi-auto mode. The fixture is manually
turned on by pressing the push-switch, and goes off automatically after hdd
time. (Absence detection mode)
Daylight threshold
Press buttons in zone ” Daylight threshold” to set daylight sensor at 2Lux/
10Lux / 50Lux / 1 00Lux / 300Lux / 500Lux / Disable.
Ambient daylight threacshold Press button “Ambient”, the surrounding lux level
is sampled and set as theew daylight threshold.
Hold-time
Press buttons in zone “hold-time” to set the hold-time at 5sec / 1min / 5min /
10 min / 15min / 30min / 60min. *To exit from Test mode, press button “RESET”
or any button in “Hold-time”.
Energy efficiency class of contained light source(s)
Indoor Luminaire cleaning
Possible cleaning equipment
It is important to clean luminaires in association with luminaire
mounting or component changing. Refiective parts surfaces should be cleaned
from dust and grime pollution.
It is also important to remember that the voltage should be disconnected
before the cleaning process is initiated. Electrical components and cables
must not be exposed to
water or detergents.
Information about luminaire’s components disassembling can be found in user’s
instructions
Switch off power supply.| Wash and wipe the outside part.| Clean the inside of
luminaire.
Do not touch or wet LED modules.| Close the luminaire tightly.| Make function
test.
Luminiare body
Vacuuming with a soft brush. Neutral dishwashing detergent with lukewarm water
/ Cleaning detergent, without grinding effects, in lukewarm water. Drying:
Self-drying in room temperature or wipe off with a slightly damp cleaning
cloth.
Reflector and diffuser cover
In case of loose dirt clean with soft duster or cleaning cloth without
microfibers, or use a compressed air . For light soiling dilute a citric acid
based cleaning product with water (e.g. 30 ml Frosch® citrus cleaner in 5
litre of water). Cleaner should be non-abrasive, pH neutral, alcohol-free. In
case of heavy soiling: Oil and grease can be removed using a mixture of
alcohol and water (1:1), e.g. methylated spirits. Residues of alcohol based
cleaning products are easily wiped away with a water-soaked cotton cloth.
Stubborn stains can be soaked in diluted citrus cleaner. Drying: Blow-off with
compressed air or use a lint-free, fresh and clean cotton cloth.
Plastic covers and caps
Vacuuming with soft brush or compressed air. In case of heavy soiling:
cleaning detergent, without grinding effects, in warm water, maximum 55
degrees Celcius. Wash with a soft, clean cloth (without microfibers) in plenty
of water. Rins with lukewarm water. Drying: Self-drying in room temperature or
wipe off with a slightly damp cleaning cloth (without microfibers).
Terms of use and maintenance
Before luminaire is turned on, it should be mounted according with this
mounting instruction or any other applicable regulations.
Mounting instructions
Mounting of luminaire must be performed by a qualified person according with following instructions:
- The warranty of luminaire does not apply, if the mounting of luminaire has been performed in precipitation (rain, snow, hail).
- The warranty of luminaire does not apply, if a control system unauthorized by VIZULO or an inapplicable LED driver has been used to drive the luminaire.
- The warranty of luminaire does not apply, if it has been used in an unsuitable ambient temperature or has been supplied by voltage outside of the specified range.
- The warranty of luminaire does not apply, if the LED driver program has been changed in any way.
- The warranty of the luminaire does not apply, if the logged history data of the LED driver has been deleted without the permission of VIZULO.
- The warranty of luminaire does not apply, if it has been mounted in unspecified angles or upside down (luminaire glass directed up), or it has been completely submerged under water.
Safety instructions
Any actions with the luminaire must be performed by a qualified person, who is
certified according with national regulations and requirements.
To prevent any accidents person installing the luminaire must follow national
safety requirements and following instructions:
- The label containing technical parameters of the luminaire has to be studied before the work on it has begun.
- Any luminaire build or design changes are prohibited.
- The luminaire must be used in good technical condition and according with this instruction.
- Only VIZULO authorized spare parts and accessories can be used to repair the luminaire.
- The repair of luminaire has to be performed by a qualified and certified person.
Maintenance and repair
Luminaire has to be disconnected from electrical grid before it is opened and/or repaired!
- The person working with the luminaire must follow national regulations and legislations that apply to maintenance and testing of electrical or electronic appliances.
- The luminaire may need to be cleaned depending on its environment. Only a damp cloth or a sponge may be used to clean the luminaire. Use only household detergents diluted by water.
- Only VIZULO authorized spare parts may be used for the luminaire.
- Instruction for changing spare parts must be requested from VIZULO and studied before the repair is attempted.
- LED modules, lens and LED drivers can be changed on an installed luminaire, but it is advised to perform this task indoor to avoid water entering the luminaire.
- Spare parts (lens, LED modules and drivers) should be ordered from the information available on the luminaire label.