VIZULO STRAW LED Linear luminaire 220 Instructions
- June 3, 2024
- VIZULO
Table of Contents
STRAW LED Linear luminaire 220
Instructions
STRAW LED Linear luminaire 220
VIZULO STRAW LED Linear luminaire
Mounting instruction
- Depends on configuration. Check label or technical specification.
Dimensions
Install prism only in a clean room using gloves!
Prism cover may accumulate small electrostatic charges that makes it
susceptible to dust and other small particles; It should only be cleaned using
dry microfiber cloth or compressed air duster.
Remove all protective film before installing the prism!
Mounting
Mounting dimensions
Use level to chek if the luminaire is parallel to the ground!
Remove all protective film before installing the diffusor!
WARNING!
- Do not touch LED modules!
- Do not put any tools or other items on LED modules!
- In case any LED is physically damaged (example shown below) the warranty is void.
Energy efficiency class of contained light source(s)
Indoor Luminaire cleaning
Possible cleaning equipment
It is important to clean luminaires in association with luminaire
mounting or component changing. Refiective parts surfaces should be cleaned
from dust and grime pollution.
It is also important to remember thatthe voltage should be disconnected
before the cleaning process is initiated. Electrical components and cables
must not be exposed to
water or detergents.
Information about luminaire’s components disassembling can be found in
user’s instructions
Cleaning and drying
Luminiare body
Vacuuming with a soft brush. Neutral dishwashing detergent with lukewarm water
/ Cleaning detergent, without grinding effects, in lukewarm water. Drying:
Self-drying in room temperature or wipe off with a slightly damp cleaning
cloth.
Reflector and diffuser cover
In case of loose dirt clean with soft duster or cleaning cloth without
microfibers, or use a compressed air . For light soiling dilute a citric acid
based cleaning product with water (e.g. 30 ml Frosch® citrus cleaner in 5
litre of water). Cleaner should be non-abrasive, pH neutral, alcohol-free. In
case of heavy soiling: Oil and grease can be removed using a mixture of
alcohol and water (1:1), e.g. methylated spirits. Residues of alcohol based
cleaning products are easily wiped away with a water-soaked cotton cloth.
Stubborn stains can be soaked in diluted citrus cleaner. Drying: Blow-off with
compressed air or use a lint-free, fresh and clean cotton cloth.
Plastic covers and caps
Vacuuming with soft brush or compressed air. In case of heavy soiling:
cleaning detergent, without grinding effects, in warm water, maximum 55
degrees Celcius. Wash with a soft, clean cloth (without microffbers) in plenty
of water. Rins with lukewarm water. Drying: Self-drying in room temperature or
wipe off with a slightly damp cleaning cloth (without microffbers).
Terms of use and maintenance
Before luminaire is turned on, it should be mounted according with this
mounting instruction or any other applicable regulations.
Mounting instructions
Mounting of luminaire must be performed by a qualified person according
with following instructions:
- The warranty of luminaire does not apply, if the mounting of luminaire has been performed in precipitation (rain, snow, hail).
- The warranty of luminaire does not apply, if a control system unauthorized by VIZULO or an inapplicable LED driver has been used to drive the luminaire.
- The warranty of luminaire does not apply, if it has been used in an unsuitable ambient temperature or has been supplied by voltage outside of the specified range.
- The warranty of luminaire does not apply, if the LED driver program has been changed in any way.
- The warranty of the luminaire does not apply, if the logged history data of the LED driver has been deleted without the permission of VIZULO.
- The warranty of luminaire does not apply, if it has been mounted in unspecified angles or upside down (luminaire glass directed up), or it has been completely submerged under water.
Safety instructions
Any actions with the luminaire must be performed by a qualified person, who is
certified according with national regulations and requirements.
To prevent any accidents person installing the luminaire must follow national
safety requirements and following instructions:
- The label containing technical parameters of the luminaire has to be studied before the work on it has begun.
- Any luminaire build or design changes are prohibited.
- The luminaire must be used in good technical condition and according with this instruction.
- Only VIZULO authorized spare parts and accessories can be used to repair the luminaire.
- The repair of luminaire has to be performed by a qualified and certified person.
Maintenance and repair
Luminaire has to be disconnected from electrical grid before it is opened and/or repaired!
- The person working with the luminaire must follow national regulations and legislations that apply to maintenance and testing of electrical or electronic appliances.
- The luminaire may need to be cleaned depending on its environment. Only a damp cloth or a sponge may be used to clean the luminaire. Use only household detergents diluted by water.
- Only VIZULO authorized spare parts may be used for the luminaire.
- Instruction for changing spare parts must be requested from VIZULO and studied before the repair is attempted.
- LED modules, lens and LED drivers can be changed on an installed luminaire, but it is advised to perform this task indoor to avoid water entering the luminaire.
- Spare parts (lens, LED modules and drivers) should be ordered from the information available on the luminaire label.
25-04-2022
SIA VIZULO
Laucu Lejas, Iecava, Latvia, LV-3913
www.vizulo.com