VIZULO OAK Gen 2 LED Industrial Luminaire Instruction Manual

May 15, 2024
VIZULO

VIZULO OAK Gen 2 LED Industrial Luminaire

VIZULO-OAK-Gen-2-LED-Industrial-Luminaire-PRODUCT

Product Information

  • Specifications
    • Model: VIZULO OAK Gen 2
    • Type: LED Industrial Luminaire
    • Voltage: 220 – 240 V
    • IP Rating: IP23
    • Weight: 1.35 – 2.55 kg
    • Dimensions: Various sizes are available, refer to the manual

Product Usage Instructions

  • Mounting Instructions
    • Follow these steps to mount the LED industrial luminaire:
    • Choose the appropriate mounting method: surface mounting, wire mounting, or mounting with Canalis.
    • Ensure proper installation torque for screws and connectors as indicated in the manual.
    • Use protection mesh if required.
    • Connect the wires according to the provided diagram.
  • Installation Guidelines
    • When installing the luminaire:
    • Install in a clean room environment.
    • Wear gloves to prevent contamination during installation.
    • Avoid accumulation of dust and particles on the diffuser cover.
    • Ensure electrical connections are secure and follow wiring instructions carefully.
  • Maintenance and Safety
    • For maintenance and safety:
    • Replace the light source only with assistance from the manufacturer or a qualified professional.
    • Avoid electrical shock risks by following proper installation procedures.

FAQs

  • Can I install the LED luminaire in any environment?
    • The LED luminaire should be installed in a clean room environment to ensure proper functioning and longevity.
  • How do I handle the maintenance of the luminaire?
    • Maintenance tasks, including light source replacement, should be carried out by the manufacturer, their service agent, or a qualified individual to prevent risks.

MOUNTING INSTRUCTION

VIZULO-OAK-Gen-2-LED-Industrial-Luminaire-FIG-1 \(2\)

NETTO WEIGHT

  • WEIGHT MIN- MAX 1.35 – 2.55 kg

DIMENSIONS

VIZULO-OAK-Gen-2-LED-Industrial-Luminaire-FIG-1 \(3\)

Install LED luminaire only in a clean room using gloves! Diffuser cover may accumulate small electrostatic charges that make it susceptible to dust and other small particles.

Surface mounting

VIZULO-OAK-Gen-2-LED-Industrial-Luminaire-FIG-1 \(6\)

Wire mounting

VIZULO-OAK-Gen-2-LED-Industrial-Luminaire-FIG-1 \(7\)

Mounting with Canalis

VIZULO-OAK-Gen-2-LED-Industrial-Luminaire-FIG-1 \(8\)

Protection mesh

VIZULO-OAK-Gen-2-LED-Industrial-Luminaire-FIG-1 \(10\)

INSTALLATION AND USING INSTRUCTION

VIZULO-OAK-Gen-2-LED-Industrial-Luminaire-FIG-1 \(11\)

Caution, risk of electrical shock! The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.

VIZULO-OAK-Gen-2-LED-Industrial-Luminaire-FIG-1 \(13\)

Remove all protective film before installing the diffuser/prism! Avoid misuse of the diffuser/prism!

WARNING!

  • Do not touch LED modules!
  • Do not put any tools or other items on LED modules!
  • In case any LED is physically damaged (example shown below) the warranty is void.

Energy efficiency class of contained light source(s)

Luminaire cleaning

  • It is important to clean luminaires in association with luminaire mounting or component changes.
  • Reflective parts surfaces should be cleaned from dust and grime pollution.
  • It is also important to remember that the voltage should be disconnected before the cleaning process is initiated.
  • Electrical components and cables must not be exposed to water or detergents.VIZULO-OAK-Gen-2-LED-Industrial-Luminaire-FIG-1 \(17\)

Cleaning and drying

  • Luminaire body: Vacuuming with a soft brush. Neutral dishwashing detergent with lukewarm water / Cleaning detergent, without grinding effects, in lukewarm water.
  • Drying: Self-drying at room temperature or wipe off with a slightly damp cleaning cloth.
  • Reflector and diffuser cover: In case of loose dirt clean with a soft duster or cleaning cloth without microfibers, or use compressed air. For light soiling dilute a citric acid-based cleaning product with water (e.g. 30 ml Frosch® citrus cleaner in 5 litres of water). The cleaner should be non-abrasive, pH-neutral, and alcohol-free.
  • In case of heavy soiling: Oil and grease can be removed using a mixture of alcohol and water (1:1), e.g. methylated spirits. Residues of alcohol-based cleaning products are easily wiped away with a water-soaked cotton cloth. Stubborn stains can be soaked in diluted citrus cleaner.
  • Drying: Blow off with compressed air or use a lint-free, fresh and clean cotton cloth.
  • Plastic covers and caps: Vacuuming with a soft brush or compressed air.
  • In case of heavy soiling: cleaning detergent, without grinding effects, in warm water, a maximum of 55 degrees Celcius. Wash with a soft, clean cloth (without microfibers) in plenty of water. Rinse with lukewarm water.
  • Drying: Self-drying at room temperature or wipe off with a slightly damp cleaning cloth (without microfibers).

MCB/Inrush current table

Length| Total LEDs| Power range| Driver op�on – series| In-rush **current ****(peak/dura�on)| B10A| B13A| B16A| B20A| B25A| C10A| C13A| C16A| C20A| C25A
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
600 mm| 176| 15 – 26 W| Standard 50 W (EXC)| 32 A (240 µs)| 10| 13| 16| 21| 26| 16| 21| 26| 35| 43
1200 mm| 352| 27 – 49 W| Standard 50 W (EXC)| 32 A (240 µs)| 10| 13| 16| 21| 26| 16| 21| 26| 35| 43
50 – 67 W| Standard 75 W (EXC)| 58 A (217 µs)| 6| 8| 10| 12| 15| 10| 13| 16| 21| 26
68 – 86 W| Standard 100 W (EXC)| 58 A (217 µs)| 6| 8| 10| 12| 15| 10| 13| 16| 21| 26
50 – 110 W| Industrial 105 W (EXC3)| 5 A (1000 µs)| 20| 25| 32| 40| 50| 33| 41| 53| 66| 82
1500 mm| 440| 40 – 62 W| Standard 75 W (EXC)| 30 A (253 µs)| 10| 13| 16| 21| 26| 16| 21| 26| 35| 43
63 – 105 W| Standard 100 W (EXC)| 58 A (217 µs)| 6| 8| 10| 12| 15| 10| 13| 16| 21| 26
50 – 110 W| Industrial 105 W (EXC3)| 5 A (1000 µs)| 20| 25| 32| 40| 50| 33| 41| 53| 66| 82
111 – 136 W| Industrial 150 W (EXC3)| 5 A (2500 µs)| 10| 12| 16| 20| 25| 16| 21| 27| 33| 41
1800 mm| 528| 40 – 62 W| Standard 75 W (EXC)| 30 A (253 µs)| 10| 13| 16| 21| 26| 16| 21| 26| 35| 43
63 – 105 W| Standard 100 W (EXC)| 58 A (217 µs)| 6| 8| 10| 12| 15| 10| 13| 16| 21| 26
50 – 110 W| Industrial 105 W (EXC3)| 5 A (1000 µs)| 20| 25| 32| 40| 50| 33| 41| 53| 66| 82
111 – 136 W| Industrial 150 W (EXC3)| 5 A (2500 µs)| 10| 12| 16| 20| 25| 16| 21| 27| 33| 41
Tridonic LED driver (DALI)**

Length

|

Total LEDs

|

Power range

|

Driver op�on – series

| In-rush **current ****(peak/dura�on)| B10A| B13A| B16A| B20A| B25A| C10A| C13A| C16A| C20A| C25A
600 mm| 176| 15 – 26 W| Standard 50 W (PRE)| 22 A (176 µs)| 13| 17| 22| 27| 33| 21| 28| 36| 45| 56
1200 mm| 352| 27 – 54 W| Standard 50 W (PRE)| 22 A (176 µs)| 13| 17| 22| 27| 33| 21| 28| 36| 45| 56
55 – 71 W| Standard 75 W (PRE)| 29 A (155 µs)| 13| 17| 22| 27| 33| 21| 28| 36| 45| 56
72 – 90 W| Standard 100 W (PRE)| 33 A (280 µs)| 6| 8| 10| 13| 16| 10| 13| 16| 21| 26
75 – 110 W| Industrial 150 W (PRE)| 18 A (162 µs)| 17| 20| 22| 25| 31| 28| 33| 36| 41| 51
1500 mm| 440| 40 – 64 W| Standard 75 W (PRE)| 23 A (174 µs)| 13| 17| 22| 27| 33| 21| 28| 35| 45| 56
65 – 110 W| Standard 100 W (PRE)| 33 A (280 µs)| 6| 8| 10| 13| 16| 10| 13| 16| 21| 26
75 – 136 W| Industrial 150 W (PRE)| 18 A (162 µs)| 17| 20| 22| 25| 31| 28| 33| 36| 41| 51
1800 mm| 528| 40 – 76 W| Standard 75 W (PRE)| 23 A (174 µs)| 13| 17| 22| 27| 33| 21| 28| 35| 45| 56
77 – 110 W| Standard 100 W (PRE)| 33 A (280 µs)| 6| 8| 10| 13| 16| 10| 13| 16| 21| 26
75 – 136 W| Industrial 150 W (PRE)| 18 A (162 µs)| 17| 20| 22| 25| 31| 28| 33| 36| 41| 51
Helvar LED driver (Non-Dimmable)
Length| Total LEDs| Power range| Driver op�on – series| In-rush ****current ****(peak/dura�on)| B10A| B13A| B16A| B20A| B25A| C10A| C13A| C16A| C20A| C25A
600 mm| 176| 15 – 23 W| Standard 42 W (LL1-CC)| 23 A (176 µs)| 21| 27| 34| 42| 52| 35| 46| 57| 71| 88
1200 mm| 352| 27 – 42 W| Standard 42 W (LL1-CC)| 23 A (176 µs)| 21| 27| 34| 42| 52| 35| 46| 57| 71| 88
49 – 84 W| Standard 80 W (LL1-CC)| 39 A (166 µs)| 9| 12| 15| 19| 23| 16| 20| 26| 32| 40
85 – 87 W| Standard 110 W (LL1-CC)| 41 A (221 µs)| 8| 10| 13| 16| 20| 13| 17| 22| 27| 33
1500 mm| 440| 40 – 53 W| Standard 80 W (LL1-CC)| 40 A (173 µs)| 11| 14| 18| 22| 27| 18| 24| 30| 37| 46
60 – 84 W| Standard 80 W (LL1-CC)| 39 A (166 µs)| 9| 12| 15| 19| 23| 16| 20| 26| 32| 40
85 – 108 W| Standard 110 W (LL1-CC)| 41 A (221 µs)| 8| 10| 13| 16| 20| 13| 17| 22| 27| 33
40 – 63 W| Standard 80 W (LL1-CC)| 40 A (173 µs)| 11| 14| 18| 22| 27| 18| 24| 30| 37| 46
1800 mm| 528| 72 – 84 W| Standard 80 W (LL1-CC)| 39 A (166 µs)| 9| 12| 15| 19| 23| 16| 20| 26| 32| 40
85 – 116 W| Standard 110 W (LL1-CC)| 41 A (221 µs)| 8| 10| 13| 16| 20| 13| 17| 22| 27| 33
117 – 130 W| Standard 150 W (LL1-CC)| 58 A (208 µs)| 7| 9| 11| 14| 17| 11| 15| 19| 23| 28
Helvar LED driver (DALI)
Length| Total LEDs| Power range| Driver op�on – series| In-rush ****current ****(peak/dura�on)**| B10A| B13A| B16A| B20A| B25A| C10A| C13A| C16A| C20A| C25A
600 mm| 176| 16 – 23 W| Standard 42 W (LL1-CC)| 25 A (176 µs)| 19| 25| 31| 39| 48| 32| 42| 53| 66| 82
1200 mm| 352| 27 – 42 W| Standard 42 W (LL1-CC)| 25 A (176 µs)| 19| 25| 31| 39| 48| 32| 42| 53| 66| 82
50 – 86 W| Standard 80 W (LL1-CC)| 42 A (166 µs)| 11| 14| 18| 22| 27| 18| 24| 30| 37| 46
87 – 91 W| Standard 110 W (LL1-CC)| 46 A (221 µs)| 8| 10| 13| 16| 20| 13| 17| 22| 27| 33
1500 mm| 440| 40 – 53 W| Standard 80 W (LL1-CC)| 41 A (173 µs)| 11| 15| 18| 23| 28| 19| 24| 31| 38| 47
62 – 86 W| Standard 80 W (LL1-CC)| 42 A (166 µs)| 11| 14| 18| 22| 27| 18| 24| 30| 37| 46
87 – 110 W| Standard 110 W (LL1-CC)| 46 A (221 µs)| 8| 10| 13| 16| 20| 13| 17| 22| 27| 33
1800 mm| 528| 40 – 64 W| Standard 80 W (LL1-CC)| 41 A (173 µs)| 11| 15| 18| 23| 28| 19| 24| 31| 38| 47
73 – 86 W| Standard 80 W (LL1-CC)| 42 A (166 µs)| 11| 14| 18| 22| 27| 18| 24| 30| 37| 46
87 – 110 W| Standard 110 W (LL1-CC)| 46 A (221 µs)| 8| 10| 13| 16| 20| 13| 17| 22| 27| 33
111 – 129 W| Standard 150 W (LL1-CC)| 44 A (208 µs)| 8| 11| 14| 18| 22| 14| 19| 24| 30| 37

Terms of use and maintenance

  • Before the luminaire is turned on, it should be mounted according to this mounting instruction or any other applicable regulations.

Mounting instructions

  • Mounting of the luminaire must be performed by a qualified person according with following instructions:
  • The warranty of the luminaire does not apply if the mounting of the luminaire has been performed in precipitation (rain, snow, hail).
  • The warranty of the luminaire does not apply if a control system unauthorized by VIZULO or an inapplicable LED driver has been used to drive the luminaire.
  • The warranty of the luminaire does not apply if it has been used at an unsuitable ambient temperature or has been supplied by voltage outside of the specified range.
  • The warranty of the luminaire does not apply if the LED driver program has been changed in any way.
  • The warranty of the luminaire does not apply if the logged history data of the LED driver has been deleted from VIZULO.
  • The warranty of the luminaire does not apply, if it has been mounted in unspecified angles or upside down (luminaire glass directed up), or if it has been completely submerged underwater.

Safety instructions

  • Any actions with the luminaire must be performed by a qualified person, who is certified according to national regulations and requirements.

To prevent any accidents person installing the luminaire must follow national safety requirements and instructions:

  • The label containing the technical parameters of the luminaire has to be studied before the work on it has begun.
  • Any luminaire build or design changes are prohibited.
  • The luminaire must be used in good technical condition and according to this instruction.
  • Only VIZULO-authorized spare parts and accessories can be used to repair the luminaire.
  • The repair of the luminaire has to be performed by a qualified and certified person.

Maintenance and repair

  • The luminaire has to be disconnected from the electrical grid before it is opened and/or repaired!
  • The person working with the luminaire must follow national regulations and legislations that apply to the maintenance and testing of electrical or electronic appliances.
  • The luminaire may need to be cleaned depending on its environment. Only a damp cloth or a sponge may be used to clean the luminaire. Use only household detergents diluted by water.
  • Only VIZULO-authorized spare parts may be used for the luminaire.
  • Instruction for changing spare parts must be requested from VIZULO and studied before the repair is attempted.
  • LED modules, lenses and LED drivers can be changed on an installed luminaire, but it is advised to perform this task indoors to avoid water entering the luminaire.
  • Spare parts (lens, LED modules and drivers) should be ordered from the information available on the luminaire label.

CONTACT

  • 12.01.2024
  • SIA VIZULO
  • Laucu Lejas, Iecava, Latvia, LV – 3913
  • www.vizulo.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals