Product

Product Information

  • Model: VIZULO Lapwing Mushroom LED Street Luminaire
  • Voltage: 200 – 240 V
  • IP Rating: IP66
  • Impact Protection: IK08
  • Weight: 9.20 – 10.60 kg
  • Dimensions: SCd = 0.047 m, suitable for mounting heights of 4 – 12 m

Product Usage Instructions

Mounting Instructions:
Follow the steps below for proper mounting of the luminaire:

  1. Identify a suitable mounting location based on the luminaire’s dimensions and recommended mounting height.
  2. Ensure the electrical supply voltage is within the specified range (200 – 240 V).
  3. Securely attach the luminaire using the provided mounting hardware, following the recommended torque settings.
  4. Connect the luminaire to the power supply as per electrical standards and regulations.
  5. Verify proper installation and alignment of the luminaire before energizing.

Safety Instructions:
For safety reasons, please adhere to the following precautions:

  • Do not attempt to replace the light source yourself; contact the manufacturer or a qualified service person for any replacements.
  • Be cautious of electrical shock risks during installation and maintenance procedures.

Frequently Asked Questions

Q: Can I replace the light source in the luminaire myself?

A: No, it is recommended to have the light source replaced by the manufacturer, a service agent, or a qualified person.

Q: What IP rating does the luminaire have?

A: The luminaire has an IP66 rating, indicating it is dust-tight and protected against powerful water jets.

Q: What is the recommended weight range for this product?

A: The net weight of the luminaire should fall within the range of 9.20 - 10.60 kg.

Features

VIZULO-LW-MUSHROOM-Lapwing-Mushroom-LED-Street-Luminaire-Fig-
\(1\)

NETTO WEIGHT

  • WEIGHT MIN – MAX 9.20 – 10.60 kg

DIMENSIONS

VIZULO-LW-MUSHROOM-Lapwing-Mushroom-LED-Street-Luminaire-Fig-
\(2\)

INSTALLATION

VIZULO-LW-MUSHROOM-Lapwing-Mushroom-LED-Street-Luminaire-Fig-
\(3\) VIZULO-LW-MUSHROOM-Lapwing-
Mushroom-LED-Street-Luminaire-Fig- \(4\)

Caution, risk of electrical shock!
The light source contained in this luminaire shall only be replaced by the manufacturer his service agent or a similar qualified person.

ATTENTION!
In the case of NEMA/ZHAGA Socket. IP66 applies only to the luminaire body and the connection between the luminaire body and NEMA/ZHAGA Sket and does not apply to any mounted control device and connection between the control device and NEMA/ZHAGA Socket.

VIZULO-LW-MUSHROOM-Lapwing-Mushroom-LED-Street-Luminaire-Fig-
\(6\)

The direction of light for asymmetric lens Module count varies from 1 to 4

VIZULO-LW-MUSHROOM-Lapwing-Mushroom-LED-Street-Luminaire-Fig-
\(7\)

The luminaire should be positioned so that prolonged staring into the luminaire is not expected from a distance closer than shown in the table above.

WARNING!

  • Do not touch LED modules!
  • Do not put any tools or other items on LED modules!
  • In case any LED is physically damaged (example shown below) the warranty is void.

Energy efficiency class of contained light source(s)

VIZULO-LW-MUSHROOM-Lapwing-Mushroom-LED-Street-Luminaire-Fig-
\(10\)

MCB/Inrush current

MCB/Inrush current table

Tridonic LED driver (No dim/Midnight dimming/DALI)

STANDARD / HIGH DENSITY| IN-RUSH CURRENT (peak/duration)| B10A| B13A| B16A| B20A| B25A| B32A| B40A| C10A| C13A| C16A| C20A| C25A| C32A| C40A
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
6-12 LED, 8-26W| 15 A (226 µs)| 19| 25| 30| 37| 46| 59| 74| 31| 41| 50| 61| 76| 97| 122
12-20 LED, 20-43W| 25 A (236 µs)| 12| 16| 20| 26| 32| 41| 52| 20| 26| 33| 43| 53| 68| 86
20-28 LED, 30-64W| 32 A (335 µs)| 6| 8| 10| 13| 16| 20| 26| 10| 13| 16| 21| 26| 33| 42
28-48 LED, 45-96W| 42 A (238 µs)| 6| 8| 10| 13| 16| 20| 26| 10| 13| 17| 22| 27| 35| 44
48-64 LED, 70-144W| 65 A (268 µs)| 3| 4| 5| 6| 7| 9| 12| 5| 7| 8| 10| 12| 16| 20
64-96 LED, 100-178W| 80 A (225 µs)| 4| 6| 8| 10| 12| 16| 20| 6| 10| 13| 16| 20| 25| 32
ECO|  | B10A| B13A| B16A| B20A| B25A| B32A| B40A| C10A| C13A| C16A| C20A| C25A| C32A| C40A
4-4 LED, 9-20W| 15 A (226 µs)| 19| 25| 30| 37| 46| 59| 74| 31| 41| 50| 61| 76| 97| 122
4-8 LED, 20-38W| 25 A (236 µs)| 12| 16| 20| 26| 32| 41| 52| 20| 26| 33| 43| 53| 68| 86
8-12 LED, 30-57W| 32 A (335 µs)| 6| 8| 10| 13| 16| 20| 26| 10| 13| 16| 21| 26| 33| 42
12-24 LED, 45-96W| 42 A (238 µs)| 6| 8| 10| 13| 16| 20| 26| 10| 13| 17| 22| 27| 35| 44
24-32 LED, 70-144W| 65 A (268 µs)| 3| 4| 5| 6| 7| 9| 12| 5| 7| 8| 10| 12| 16| 20
32-52 LED, 100-178W| 80 A (225 µs)| 4| 6| 8| 10| 12| 16| 20| 6| 10| 13| 16| 20| 25| 32

Terms of use and maintenance

Before the luminaire is turned on, it should be mounted according to this mounting instruction or any other applicable regulations.

Mounting instructions
Mounting of the luminaire must be performed by a qualified person according to the following instructions:

  • The warranty of the luminaire does not apply if the mounting of the luminaire has been performed in precipitation (rain, snow, hail).
  • The warranty of the luminaire does not apply if a control system unauthorized by VIZULO or an inapplicable LED driver has been used to drive the luminaire.
  • The warranty of the luminaire does not apply if it has been used at an unsuitable ambient temperature or has been supplied by voltage outside of the specified range.
  • The warranty of the luminaire does not apply if the LED driver program has been changed in any way.
  • The warranty of the luminaire does not apply if the logged history data of the LED driver has been deleted from VIZULO.
  • The warranty of the luminaire does not apply if it has been mounted at unspecified angles or upside down (luminaire glass directed up), or if it has been completely submerged underwater.

Safety instructions
Any actions with the luminaire must be performed by a qualified person, who is certified according to national regulations and requirements. To prevent any accidents person installing the luminaire must follow national safety requirements and instructions:

  • The label containing the technical parameters of the luminaire has to be studied before the work on it has begun.
  • Any luminaire build or design changes are prohibited.
  • The luminaire must be used in good technical condition and according to this instruction.
  • Only VIZULO-authorized spare parts and accessories can be used to repair the luminaire.
  • The repair of the luminaire has to be performed by a qualified and certified person.

Maintenance and repair
The luminaire has to be disconnected from the electrical grid before it is opened and/or repaired!

  • The person working with the luminaire must follow national regulations and legislations that apply to the maintenance and testing of electrical or electronic appliances.
  • The luminaire may need to be cleaned depending on its environment. Only a damp cloth or a sponge may be used to clean the luminaire. Use only household detergents diluted by water.
  • Only VIZULO-authorized spare parts may be used for the luminaire.
  • Instruction for changing spare parts must be requested from VIZULO and studied before the repair is attempted.
  • LED modules, lenses and LED drivers can be changed on an installed luminaire, but it is advised to perform this task indoors to avoid water entering the luminaire.
  • Spare parts (lens, LED modules and drivers) should be ordered from the information available on the luminaire label.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals