Safety instructions

Warning
This appliance is intended for indoor use only in private homes. Any other use is not recommended by the manufacturer and may cause fire, electric shock, or other personal injury or damage.

Power cord

  • Do not try to unplug the power cord from the wall socket.
  • Do not connect the appliance to an overloaded extension lead.
  • Do not place heavy objects on the power cord in order to avoid safety risks.
  • Do not use the appliance if the power cord cannot be securely fastened in the plug socket.
  • Do not attempt to replace the power cord, contact the authorised service workshop for repair.
  • Do not touch the plug with wet hands in order in order to avoid electric shock.
  • The socket must be grounded and properly secured.
  • Unplug it during lightning storms.

Location

  • Do not place flammable and explosive objects around the appliance in order to avoid fire.
  • Place the appliance on a stable, flat surface.
  • Do not use the appliance in locations with a draught.

During use

  • Turn off the power and unplug the power cord before moving the device.
  • Do not pour water into the appliance in order to avoid malfunction.
  • Children should be supervised to ensure that they do not play with the appliance.
  • Do not place heavy objects on the appliance in order to avoid malfunction.
  • The apparatus must not be knocked over or subjected to impact or shock in order to avoid malfunction.
  • The appliance must not be covered when in use.
  • Do not place your hands on the air outlet in order to avoid damage or malfunction.

Parts list

Componentseeese-2514-Air-Purifier-and-Humidifier-Martha-
\(1\)

  1. Housing cover

  2. Water tank

  3. Air outlet

  4. Display

  5. Air inlet

  6. Carbon filter

  7. Inlet Cover

  8. Cable

  9. Disc

  10. Tray
    Control Paneleeese-2514-Air-Purifier-and-Humidifier-Martha-
\(2\)

  11. ON/OFF button

  12. Timer button

  13. Fan speed button

  14. Target humidity button

  15. Heating button

  16. Timer symbol

  17. Target humidity/current humidity

  18. Heating indicator

  19. Fan speed settings

Prior to Operation

eeese-2514-Air-Purifier-and-Humidifier-Martha- \(3\)

  • Place the humidifier on a firm, level and water-resistant surface to prevent any vibrations or noise.
  • Ensure the humidifier is at a safe distance at least 30 cm away from a wall or furniture.
  • Make sure that the air inlet and air outlet are never blocked.

Before operation

Before First Useeeese-2514-Air-Purifier-and-Humidifier-Martha-
\(4\)

  1. Place the unit upright on a firm, flat surface. For proper air circulation make sure the vented sides are at least 18-20 degrees clear of any wall. Do not block airflow inlets and outlets. Unrestricted airflow will result in the best efficiency and performance of your humidifier.
  2. Inspect the power cord to insure it is free of damages.
  3. Make sure the upper housing cover is removed from the lower housing.
  4. Place Disc stack(s) into lower housing.
  5. Add fresh tap water. Fill water to the water tank. You can transport the lower housing to your sink or tub –or you may fill the lower housing by carrying the water in a pitcher or a watering can to the lower housing. Be careful when filling, cleaning, or moving the humidifier to avoid water spills. Do not fill your humidifier through the air inlet holes on side cover. Place the water tank properly on top of lower housing.
  6. Plug power cord into standard AC outlet.

NOTICE! We recommend using demineralized water to prevent your machine from lime if you have hard tap water.

Instruction manual

Daily Use and Operation

eeese-2514-Air-Purifier-and-Humidifier-Martha- \(5\)

  • A) Power ON/OFF
    Press Button A to turn the humidifier ON and OFF.
    Power ON Default Status: the fan rotates on its middle setting, the display shows current indoor relative humidity level.
    Connect the power supply and press the on/off button (A) once to turn on the device.

  • B) Timer Setting
    When the unit is on default working status, press button B to adjust the operating time, it can be regulated between 1 and 12 hours or for continuous operation.
    CO(Default): 01 – 02 – 03 – 04 – 05 – 06 – 07 – 08 – 09 – 10 – 11 – 12

  • C) Moisture Emission Level Setting
    Press button C to adjust the low, middle and high level of moisture emission.
    Middle – High – Low

  • D) Humidistat Setting
    Set the desired humidity in % by pressing Button D. We recommend a relative humidity of between 40% and 60%. The appliance can be regulated from 40% to 75%. If the humidity exceeds the desired setting, the appliance will turn itself off. The appliance will not turn itself off if it has been set for continuous operation (”CO”). The desired value is shown while you are making the selection. After a few seconds, the display automatically switches to the current value.
    40% – 45% – 50% – 55% – 60% – 65% – 70% – 75% – 80 % – CO

  • E) Heating Function
    Martha is also HUMIDIFIER & AIR PURIFIER the perfect humidifier in winter when the air inside is often dry. Martha incorporates a new heat technology that heats water in the tank to 65 °C and inactivates bacteria and virus in the water that evaporates into the room. Press button E to select heating function. Lights ON; press again E, its icon light OFF.

Status 1: the unit is working at CO status.
If press heating button, the unit will automatically start to heat for 25 minutes without any fan speed. After 25 minutes, the unit will automatically turn heating ON or OFF subject to current indoor humidity.
Please refer to below working status under different indoor humidity conditions.

  • Current Indoor Humidity Working status of the unit
  • 20%RH~40%RH working on high level moisture output + heating ON.
  • 40%RH~60%RH working on middle level moisture output + heating ON.
  • > 60%RH working on low level moisture output.

Status 2: The humidity is under 40%RH~80%RH status.
If you press the heating button, the unit will automatically start to heat for 25 minutes without any fan speed. After 25 minutes, the unit will keep working on middle level moisture output with heating ON, till the indoor humidity reaches up to your setting level, the unit will automatically stop working.

  • The unit can turn heating ON or OFF according to the environment temperature.
  • The unit can turn heating ON or OFF when lack of water.

Remark:

  1. If lack of water, only that the power button can be operated, other buttons are unable to operate.
  2. when heating is ON, the fan speed changes with the environment humidity to improve the basin temperature and decrease the power consumption.

IMPORTANT! When the unit is not in use, please unplug it.

Maintenance

Main components of the humidifier
When the appliance is used regularly, the filter can become clogged with dust and particles. Therefore, the filter should be changed every six month. Follow these steps:

  1. Switch the power off and unplug the power cord.
  2. Open the upper housing unit for easy access to components.
  3. Easily lift out the water tank.eeese-2514-Air-Purifier-and-Humidifier-Martha- \(6\)
  4. Pull out carefully the air inlet cover (the cover is attached with an activated carbon filter).eeese-2514-Air-Purifier-and-Humidifier-Martha- \(7\)
  5. Pull out the basin, then lift up the disc stacks.eeese-2514-Air-Purifier-and-Humidifier-Martha- \(8\)

Maintenance and Cleaning
Replacing the 3-in-1 filters (pre-filter+HEPA+Carbon filter)
The combination filter should be replaced after 1000 operating hours. The ‘CL’ symbol will automatically flash on the display after 1000 operating hours.
Martha is supplied with one filter. One side of the filter is black (pre- filter) and the other side is white (Hepa).
When replacing the filter, turn off the device and unplug it. Replace the combination filter by removing the lid. You can now remove the old filter and insert a new one. The pre-filter must face the lid before it is applied. Connect the plug to the wall socket and switch on the device. To clear the ‘CL symbol’, push and hold the fan speed key for 5 seconds, a signal sounds and the symbol disappears. The operating time meter is now reset.

  • Daily
    Fill with fresh tap water. In case of hard tap water, it is strongly recommend to use soft demineralised water instead. This minimizes potential build-up of calcium deposits

  • Every 10-14 days
    Rinse the lower housing and disc stack(s) with warm water. Take apart the Disc stacks piece by piece, clean and wipe each piece, also clean and wipe the lower housing and with soft cloth

  • Clean the filter
    Regular cleaning of the filter (once a month) is important for hygienic and fault-free operation. Clean the three-layered filter using the brush attachment of a vacuum cleaner. To carry out a thorough clean, pull out the filter and clean it by using the brush attachment from a vacuum cleaner. The three-layered filter cannot be washed.

  • Rinse   the tray
    Rinse out the tray every 2 weeks with warm water. If the air is heavily polluted, the device is used intensively, or the water quality is poor, the humidifier must be cleaned at shorter intervals. Before you can pull the tray out for cleaning, you must first pull the water tank out of the air humidifier from above. Remove any deposits in the tray using a soft cloth. We reccomend, that you do not use any corrosive, caustic or solvent-based cleaning products. You can put the tray in the dishwasher.

IMPORTANT!
WARNING! Always empty and thoroughly clean the water tank and the tray of the air humidifier if the device contains water and has not been operated for longer than 3 days. A lack of cleaning and hygiene can cause bacteria, algae and fungi to form in the water.

Cleaning the disc set
Before you clean the disc set, pull it upwards and out of the device. We reccomend you to clean the disc set every 2 weeks with warm water and a soft cloth. If it is heavily soiled, you can also clean the disc set in the dishwasher. Do not use any corrosive, caustic or solvent-based cleaning products.

Descaling
Cleaning of disc stacks – Soaking the Ddsc stacks in hot water with white vinegar for approx. 30 minutes will help loosen any buildup of calcium or lime. Always rinse with warm tap water after cleaning.
DO NOT USE: Detergent, mild soap, bleach, household cleaners. Vinegar and water solution – either a 50:50 or a 3:1 ratio of white vinegar and water can be used.

IMPORTANT!
WARNING! Always turn the power off and unplug the power cord from the A/C outlet before moving the humidifier.

Storage

We recommend a thorough cleaning of your humidifier before storing the unit. Please make sure that all components are clean and dry prior to storing. Do not leave water in the lower housing when storing. Water left in the humidifier may leave mineral deposits and allow microorganisms to grow. Repack your humidifier in its original packaging and store in a cool dry place.

Troubleshooting

Before contacting technical Support, check the following.

PROBLEM POSSIBLE CAUSE SOLUTION
Not working Lack of water in the basin? If lack of water, it won’t work,

please fill tank with water.
Is it plugged into a power sock- et?| Plug into the socket.
Is there a power outage?| Wait for the power to return
Burned fuse?| Check and change the fuse.
Is the filter change indicator flashing?| Replace the filter.
Poor perfor- mance| Is there any dust in the surface of the air inlet?| Clean the air inlet
Is there any obstacle blocking the airinlet/outlet?| Remove any blocking objects.
Significant noise| Is there anything stuck on the fan in the air outlet?| Remove any blocking objects.
Is the machine tilted?| Place Martha in the right position
Set the machine at a lower wind speed if the noise is too loud
Clicking Noise| If a mineral deposit has formed inside the gear, this could cause a clicking sound during operation| Remove it by using white vinegear solution 50/50
---|---|---
Is the ABS coupling is inserted all the way into the gear?| Make sure the ABS coupling is inserted all the way into the gear
Nasty smell| New machines tend to smell of plastic.| Give it time
Is the filter dirty?| Clean the filter with a vacuum cleaner.
Burning smell?| Unplug the machine and contact the support center
Flashing light after filter replacement| Reset the machine by holding the power button down for 5 seconds. The filter lifetime will now start from the begninng.

Technical specifications

Model Martha, Item No. 2514
Recommended working area 2 ~ 56
Airflow m3/h 79
Power (Heating OFF) W ~35
Power (Heating ON) W ~280
Moisture output (Heating OFF) 30%RH, 21° C – ml/h ~200
Moisture output (Heating ON) 30%RH, 21 °C – ml/h ~400
Power supply V/Hz 220-240~, 50-60
Timer h 1-12
IP code IPX3
Operating temperature °C 5~40
Noise level dB(A) 29 (L), 35 (M), 45(H)
Tank Capacity L 4.6
Water heating, °C 65
Net Weight kg 6.7
Gross Weight kg 7.5
Product Size (WDH) mm 370 x 260 x 362
Packing Size (WDH) mm 397 x 295 x 406
EAN 5704841025141

Service
If you have any questions or need more information, please feel free to call Customer service on +45 6916 3200
If you need service or to make a warranty claim, you must create a case directly in our support system. Go to the home page under SUPPORT.

Warranty

Limited warranty
We guarantee that all parts are free of defects in materials and workmanship for a period of two years from the date of purchase. The warranty covers only material or manufacturing defects that prevent the product from being able to be installed or operated in a normal way. Defective parts will be replaced or repaired. The warranty does not cover transportation damage, any use other than what is intended, damage caused by incorrect assembly or improper use, damage caused by impact or other error, damage caused by frost cracking or by improper storage.
The warranty becomes void if the user modifies the product.
The warranty does not include product-related damage, property damage or general operational loss.
The manufacturer’s liability cannot exceed the repair or replacement of defective parts and does not include labour costs to remove and reinstall the defective part, transportation costs to and from the service centre, and all other materials necessary to carry out the repair.

This warranty does not cover failure or malfunction as a result of the following:

  • If the unit is not installed, operated or maintained in accordance with the instruction manual supplied with the unit .
  • The workmanship of any installation of the unit.
  • Misuse, alteration, accident, fire, flood, lightning strike, rodents, insects, negligence or unforeseen events.
  •  Use of non-factory authorised parts or accessories in conjunction with the product.

Limitation of liability
This is the only warranty provided by the manufacturer. No one is authorised to make any other warranties on our behalf. This warranty is in lieu of all other warranties, expressed or implied, including but not limited to any implied warranty of fitness for a particular purpose and saleability. We expressly disclaim any liability for consequential, incidental, indirect, or consequential damages resulting from any breach of the express or implied warranties. This warranty gives you specific legal rights, which may vary by country.

Complaints
In the event of any warranty claim a valid purchase receipt must be presented. Read about making warranty claims in the SERVICE section.

eeese air care.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals