eeese 2538 Full Inverter Dehumidifier User Manual

June 3, 2024
eeese

eeese logo 2538 Full Inverter Dehumidifier
User Manual
eeese 2538 Full Inverter Dehumidifier

2538 Full Inverter Dehumidifier

Read the user manual before use, refer to the corresponding section of these user instructions.
Recycle unwanted materials instead of disposing of them. All appliances and packages must be sorted and delivered to a regional recycling centre and processed in an environmentally friendly manner.
The product complies with the applicable EU directives and other provisions.
This device uses a flammable refrigerant.
If refrigerant leaks and comes into contact with a fire or heating element, it creates harmful gas and there is a risk of fire.

Safety instructions

Warning
This appliance is intended for indoor use only in private homes. Any other use is not recommended by the manufacturer and may cause fire, electric shock, or other personal injury or damage.

Power cord

|
---|---
Do not try to unplug the power cord from the wall socket.| Do not place heavy objects on the power cord in order to avoid safety risks.
|
Do not attempt to replace the power cord, contact the authorised service workshop for repair.| The socket must be grounded and properly secured.
|
Do not connect the appliance to an overloaded extension lead.| Do not use the appliance if the power cord cannot be securely fastened in  he plug socket.
|
Do not touch the plug with wet hands in order in order to avoid electric shock.| Unplug it during lightning storms.

Location

| |
---|---|---
Do not place flammable and explosive objects around the appliance in order to avoid fire.| Do not use the appliance in locations with a draught.| Place the appliance on a stable, flat surface.

During use

|
---|---
Turn off the power and unplug the power cord before moving the device.| Children should be supervised to ensure that they do not play with the appliance.
|
The apparatus must not be knocked over or subjected to impact or shock in order to avoid malfunction.| Do not place your hands on the air outlet in order to avoid damage or malfunction.
|
Do not pour water into the appliance in order to avoid
malfunction.| Do not place heavy objects on the appliance in order to avoid malfunction.
| The appliance must not be covered when in use.

Parts list

Components

eeese 2538 Full Inverter Dehumidifier - fig19

1. Screw x 5
2. Feet x 4
3. Drain Pipe (16 mm)
4. Hanging Bracket
5. Hanging Strip for Wall| 6. Wall Pads
7. Air Outlet
8. Control Panel
9. Foot
10. Air Inlet (in the bottom)
---|---

Control Panel

11. Dehumidifier Mode
12. WIFI Connection
13. Compressor
14. Compressor Speed
15. Humidity Level
16. Working Mode
17. Up Button
| 18. Down Button
19. Temperature
20. Timer Setting
21. On/Off Button
22. Work Mode
23. Timer
---|---

Before operation

eeese 2538 Full Inverter Dehumidifier - fig21

  • Place Axel in an upright position on a stable, level surface.

  • Ensure that the dehumidifier is at a safe distance in order to achieve optimal airflow.
    Axel can be placed as illustrated on A (on the floor) and B (mounted on the wall), at least 1 meter from the roof. There must be 2 meters free space from the front of Axel.

  • Note that the voltage supplying the unit must conform to the unit’s value and the socket must be grounded.

  • Turn on the power and start the machine according to the instructions below.

Placing the unit on the floor
The unit includes four feet. Align the foot to the mounting hole of the dehumidifier chassis and turn it in clockwise direction, picture 1.

IMPORTANT!
Do not flip the unit during installation! If the unit has been flipped always wait an hour before use.

Connect the drain pipe, and connect the power cord according to the wiring diagram A: Power Cord Entry
B: Drain Outlet (drain pipe included),
C: Foot

Mounting the unit on the wall
Step 1
The concrete foundation of the selected wall should be firm and strong.eeese
2538 Full Inverter Dehumidifier - fig23Mount the bracket (picture 2) to the wall by attaching the five (included) screws to the holes in the wall.

Step 2
Place the pad A (picture 3) on the wall-mounting holes behind the unit, . Step 3
Hang the unit (picture 4 – 5) from the hanging strip on the back and on the wall fastened bracket. Make sure the pads are resting absent the wall, picture 5 – A.eeese 2538 Full Inverter Dehumidifier - fig25Step 4
Connect the drain pipe, and connect the power cord ac- cording to the wiring diagram ****

A: Power Cord
B: Drain Outlet (drain pipe included)

Instruction manual

Switching the unit on/off
Connect the power supply and press the on/off button (A) once to turn on the device. Working Mode
Axel can work in “Smart mode” (B) and “Silence mode” (C). The working capacity in “Smart mode” is up to ~100% and in “Silence mode” capacity is up to ~80%. By default Axel is set work in “Smart mode”. Pressing A will change between “Smart mode” and “Silence mode”. Dehumidifier function
The humidity setting range is between 30% and 95%. Axel is by default set to 70%. Press A or B to set the humidity percentage. The humidity setting range is between 30% and 95%. Axel is by default set to 70%.
Timer settings
The device can be set to turn off or turn on with the timer.
Timer – turning on settings
When the dehumidifier is on or off, press A to enter the timer setting. This will light up B and C will start flashing. Now press D or E to adjust the hour setting. Next, press A to set the minute and adjust with D or E. Save the setting by pressing A three times. Observe that C stops flashing and keeps lighted instead.
By not pressing D or E the timer is cancelled. Timer – turning off setting
When the dehumidifier is on or off, press A to enter the timer setting. This will light up B and C will start flashing. Press A two times for the timer off setting. F will now flash in- stead. Now press D or E to adjust the hour setting. Next, press A to set the minute and adjust with D or E. Save the setting by pressing A. Observe that F stops flashing and keeps lighted instead.
By not pressing D or E the timer is cancelled. Timer – turning on & turning off settings
When the dehumidifier is on or off, press A to enter the timer setting. This will light up B and C will start flashing (this starts the turn on setting). Now press D or E to adjust the hour setting. Next, press A to set the minute and adjust with D or E. Press A, F will start flashing (this starts the turn off setting). Now press D or E to adjust the hour setting.
Next, press A to set the minute and adjust with D or E. Save the settings by pressing A.
Observe that C and F keeps lighted. Cancelling the timer
Press A to enter the timer setting. Press A again, this will cancel the turn on setting.
Press A once gain, this will enter the turn off setting and lastly press A for cancelling the turn off settings.

Cleaning

When the appliance is used regularly, the filter can become clogged with dust and particles.
Therefore, the filter should be cleaned at least every two weeks. Follow these steps:

  1.  Turn off the unit and unplug it before cleaning.
  2. Clean the cabinet with a soft, dry cloth. If the unit is very dirty, use a mild detergent. Wipe the dehumidifier with a slightly damp cloth. Never spray water on the unit.
  3. Remove the filter (air inlet in the bottom), clean the filter with a vacuum cleaner or soapy water no hotter than 40°C.

Storage

If the unit will not be used for an extended period, do the following:

  1. Unplug the unit.
  2. Clean the air filter with a vacuum cleaner.
  3. Make sure the device is in perfect condition so that it is safe to use again after a long storage period.
  4. Store the unit in appropriate packaging.
  5. Store the unit in a dust-free place and out of direct sunlight. It is recommended to cover it with a piece of plastic.

Display Error Codes

Please contact your local distributor if any of the error codes below appears.

No. Display code Error
1 El High pressure protection
2 E2 Low pressure protection
3 E5 Abnormal power supply voltage protection
5 E8 Exhaust high temperature protection
6 EA Air out high temperature protection
7 Eb Environmental low temperature protection
8 PO Controller failure
9 P1 Air inlet temperature sensor failure
10 P2 Air outlet temperature sensor failure
11 P3 Exhaust gas temp sensor failure
12 P5 Gas return temperature sensor failure
13 P6 Evaporation coil temperature sensor failure
--- --- ---
14 P7 Ambient humidity sensor failure
15 P8 Cooling plate sensor failure
16 P9 Current sensor failure
17 PA Restart memory failure
18 Fl Compressor drive module or related wiring failure
19 F2 PFC module failure
20 F3 Compressor start failure
21 F4 Compressor running failure
22 F5 Inverter board over current protection
23 F6 Inverter board overheat protection
24 F7 Over current protection
25 F8 Radiator high temperature protection
26 F9 DC fan fault
27 FA PFC module over current protection

Troubleshooting

Before contacting technical Support, check the following.

PROBLEM POSSIBLE CAUSE SOLUTION
Unit not working The power is not connected. Plug into the socket.
Burned fuse. Check and change the fuse.
The breaker is off. Check and turn on the breaker.
Display is normal, but no dehumidification The humidty set is too low. Set

proper humidity percentage.
3 minutes start delay.| Wait patiently.

IMPORTANT!
Please do not try to repair the dehumidifier by yourself to avoid any risk.

Technical specifications

Model Axel, Item No. 2538 2540 2542
Advised pool surface, m2 25 40 50
Advised room size, m2 50-120 80-200 100-240
Operating air temperature’, °C 10-38
Dehumidification capacity, Vday (Air 30°C, RH 80%) 61. 96.0 120.0
DER’, I/kWh (Air 30°C, RH 80%) 4.00-340 4.53-4.05 4.50-3.68
Dehumidification capacity, I/day (Air 30°C, RH 70% ) 50. 79. 101.
DER’, I/kWh (Air 30°C, RH 70%) 3.34-3.00 4.00-3.50 3.86-3.25
Rated power, kW (Air 30 C, RH 80%) 011-0.73 017-0.99 0.22-1.36
Rated current, A (Air 30°C, RH 80%) 0.48-317 0.74-4.30 0.96-5.91
Power supply 230V/1Ph/50Hz
Sound level dB (A) at 1 m 38 – 46 40 – 46 40 – 46
Air flow, m3/h 600 800 1000
Rated current, A 7. 8.0 10.
Fuse, A 8. 10. 11.
Power cord3, mm2 3×4 3×4 3×4
Length of cable, cm 140 140 140
Net dimension, (WXDXH) mm 850x291x770 1120x291x770 1220x291x770
Net weight 53 68 72
  1. Dehumidification Efficiency Ratio
  2. The temperature of this products can only work normally within the range of 10 °C ~ 38 °C. If it exceeds this range, the performance will not be guaranteed; please note that the performance parameters of the dehumidifier will be different under different working conditions.
  3. Above data is adapted to power cord is ≤10m. If power cord is ≥10m, wire diameter must be increased.

The above technical data is for reference only. We reserve the right to change them with- out notice.

Dimensions

eeese 2538 Full Inverter Dehumidifier - fig30

Item No.| A
mm| B
mm| C
mm| D
mm| E
mm| F
mm
---|---|---|---|---|---|---
2538| 291| 850| 276| 100| 784| 870
2540| 291| 1120| 276| 100| 1054| 870
2542| 291| 1220| 276| 100| 1154| 870

Electrical Wiring Diagram

eeese 2538 Full Inverter Dehumidifier - fig31

WI-FI SETTING

  1. APP Download
    Download the “Smarter Pool” app or the “Tuya Smart” app

  2. Account registrationeeese 2538 Full Inverter Dehumidifier - fig33eeese 2538 Full Inverter Dehumidifier - fig34

  3. App Connection
    Please make sure your mobile phone is connected to the home Wi-Fi configured to 2.4GHz.eeese 2538 Full Inverter Dehumidifier -
fig35 a) Wi-Fi connection:
    After turning on the unit, press the start button for 3 seconds. The Wi-Fi indicator will be flashing and the unit will be ready to connect.
    b) Add Device
    Press “Add device” and follow the instructions on the app to finish the connection. The Wi-Fi indicator will stop flashing on the unit once the connection has succeeded.eeese 2538 Full Inverter Dehumidifier -
fig36eeese 2538 Full Inverter Dehumidifier -
fig37 c) Connection Failure
    If connection fails, please make sure your network name and password are correct. Also make sure your router, mobile phone and device are as close as possible.
    d) Wi-Fi Reconnection
    If the Wi-Fi password or network changes configuration it is necessary to reconnect:
    Press the start button for 10 seconds. The Wi-Fi indicator will now start to flash slowly for 60 seconds and the Wi-Fi indicator will be off. The original connection will be
    deleted. Restart a new connection as shown above, “App Connection”.

  4. Operationeeese 2538 Full Inverter Dehumidifier - fig38 Note
    The unit is not equipped with electric heating.

  5. Share the unit with others
    You can share the control of the unit by having others installing and registering to the app. As an administrator you can add users with the following procedure:eeese 2538 Full Inverter Dehumidifier -
fig39

Service

If you have any questions or need more information, please feel free to call Customer service on +45 6916 3200
If you need service or to make a warranty claim, you must create a case directly in our support system. Go to the home page under SUPPORT.

Warranty

Limited warranty
We guarantee that all parts are free of defects in materials and workmanship for a period of two years from the date of purchase. The compressor has 6 years of guarantee from the date of purchase. The warranty covers only material or manufacturing defects that prevent the product from being able to be installed or operated in a normal way. Defective parts will be replaced or repaired.
The warranty does not cover transportation damage, any use other than what is intended, damage caused by incorrect assembly or improper use, damage caused by impact or
other  error, damage caused by frost cracking or by improper storage.
The warranty becomes void if the user modifies the product.
The warranty does not include product-related damage, property damage or general operational loss.
The manufacturer’s liability cannot exceed the repair or replacement of defective parts and does not include labour costs to remove and reinstall the defective part, transporta-
tion costs to and from the service centre, and all other materials necessary to carry out the repair.

This warranty does not cover failure or malfunction as a result of the following:

  • If the unit is not installed, operated or maintained in accordance with the instruction manual supplied with the unit .
  • The workmanship of any installation of the unit.
  • Misuse, alteration, accident, fire, flood, lightning strike, rodents, insects, negligence or unforeseen events.
  • Use of non-factory authorised parts or accessories in conjunction with the product.

Limitation of liability
This is the only warranty provided by the manufacturer. No one is authorised to make any other warranties on our behalf.
This warranty is in lieu of all other warranties, expressed or implied, including but not limited to any implied warranty of fitness for a particular purpose and saleability. We expressly disclaim any liability for consequential, incidental, indirect, or consequential damages resulting from any breach of the express or implied warranties.
This warranty gives you specific legal rights, which may vary by country.

Complaints
In the event of any warranty claim a valid purchase receipt must be presented. Read about making warranty claims in the SERVICE section.

eeese logo Thank you for choosing this product.
Please read this instruction manual before using it.
eeese air care
[email protected]
Web:eeese-aircare.com 
MV-2538-2540-2542-11-2022

Documents / Resources

| eeese 2538 Full Inverter Dehumidifier [pdf] User Manual
2538, 2540, Full Inverter Dehumidifier, Inverter Dehumidifier, Full Dehumidifier, Dehumidifier, 2538 Dehumidifier
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

eeese User Manuals

Related Manuals