eeese 2567 Emma Dehumidifier User Manual
- June 13, 2024
- eeese
Table of Contents
- 2567 Emma Dehumidifier
- Safety Instructions
- Parts List
- Continuous drainage
- Prior to operation
- Operation instructions
- Cleaning the dehumidifier
- Storage
- Display error codes
- Trouble Shooting
- Technical Specifications
- Service
- Warranty
- Responsible Disposal
- Warning on Refrigerant R290
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
User manual
Dehumidifier Emma
Art. 2567
2567 Emma Dehumidifier
Thank you for choosing this product.
Please read this instruction manual before using it.
eeese air care
info@eeese-aircare.com
Web: eeese-aircare.com
MV-2568-03-2023
eeese-aircare.com
© All rights eeese air care aps
Please read the user manual before any use, refer to the corresponding section
in this user manual. Save it for future reference. We reserve the right for
any error in text or images and any necessary changes made to technical data.
Recycle unwanted materials instead of disposing of them.
All appliances and packaging should be sorted and tendered at a regional
recycling centre and be processed in an ecological manner.
The product conforms to the applicable European and other directives.
Safety Instructions
Warning
This appliance is intended for use in a domestic environment only. Any other
use is not recommended by the manufacturer and may cause fire, electrical
shocks or other person injury and property damage. Never try to dismantle or
repair the machine yourself. The appliance shall be installed in accordance
with national wiring regulations. The machine is designed A-weighted sound
pressure level below 70dB. Check the voltage and make sure it meets the
technical specification of the machine. This machine can be used by children
aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way
and understand the hazards involved. Power Cord
Do not pull the power cord in order to unplug the device from the socket.
Do not put any heavy objects on the power cord in order to avoid safety
hazard.
Do not attempt to change the power cord, contact the authorized service centre
for repair. Do not use the appliance in overloaded extension cord.
Do not use the appliance if its socket holes cannot firmly hold a plug.
Do not touch the plug with wet hands in order to avoid electric shock. Unplug
the product immediately if it mits strange noises, odours or smoke. Please
pull out the plug during lightning storms. Unplug the product when it is not
in use. The socket has to be earthed and appropriately secured.
Placement
Do not put flammable and explosive objects around the appliance in order to
avoid fire.Do not use the appliance in a draughty place or
next to a radiator or heating appliance. Do not use the appliance in swimming
pool or similar facilities in order to avoid safety hazard.
Place the appliance on a stable, flat surface. The machine must always stand
upright. During Use
Before moving the dehumidifier please turn off the power, unplug the power
cord and make sure that the water tank is empty
Children shall not play with the machine. Never insert foreign objects into
the machine. Do not pour water into the appliance in order to avoid
malfunction. Do not put any heavy objects on the appliance in order to avoid
malfunction. Never sit on the product. Do not push the appliance over or let
the appliance suffer strong impact in order to avoid malfunction.
Do not put hands on the air outlet in order to avoid injury or malfunction.
The appliance must not be covered when being used.
Parts List
Components
1. Air Outlet
2. Pre Filter
3. Drainage Outlet
4. Water Tank
5. Castors| 6. Handle
7. Rear Cover
8. Power Cord
9. Control Panel
10. Front Cover
---|---
Control panel
11. Power Button
12. Timer Off Button
13. Manual Dehumidifying Button
14. Timer Indicator
15. Tank Full Indicator
16. Defrost Indicator
17. Low Fan Speed Indicator
18. High Fan Speed Indicator| 19. Fan Speed Button / Child Lock Button
20. Auto Dehumidifying Button
21. Mode Button
22. Auto Dehumidifying Indicator
23. Laundry Drying Indicator
24. Humidity Reading
25. Sleep Indicator
26. Air Purifying Indicator
---|---
Drainage
27. Drainage Outlet
28. Drainage Pipe
Drain hose not included
Continuous drainage
Continuous drainage option allows easy removal of collected water instead of manually emptying from the water tank when the environment is very high humidity.
- Remove the rubber plug covering the drain hose connection.
- Connect a suitable drain hose (14mm inner diameter) to the drainage outlet. Ensure that the hose is secure and tight to prevent leakage.
- Always make sure the drainage hose is not blocked or obstructed to maintain a smooth flow.
Please always make sure the pipe is going downwards, and is not blocked or
kinked.
Drain hose is not included, but as a extra purchase. Art. no. 2558
Prior to operation
- Check the dehumidifier for any transport damages. In case of damage, you should contact our service line immediately.
- Place the dehumidifier in an upright position on a stable, flat surface.
- Make sure that the mains lead is easily accessible and is not damaged by sharp edges or is crushed in any way during use.
- Ensure the dehumidifier is at a safe distance at least 50 cm away from a wall or furniture and has air space on all sides.
- The machine must stand upright for at least 1 hour before it is used for the first time
- If any part of your house suffers from severe humidity, the dehumidifier can be placed there first and then moved to another part of the house later.
- Ensure the power supply is in correspondence with the value on the nameplate and power outlet needs to be grounded.
- Ensure the water tank is correctly fitted before the dehumidifier can be switched on.
- If the dehumidifier is turned off and then turned back on again immediately, it will take approximately 3 minutes to reach full power (compressor back to work).
- If the dehumidifier is switched off by a power cut, it will automatically switch back on once the power is restored.
- The dehumidifier works best at normal room temperature, its efficiency is reduced if the ambient temperature falls to below 15°C.
- Turn on the power and run the machine as per instructions below.
Operation instructions
Connect the power plug to the correct power supply; the machine will enter
into standby with “beeping” sound.
Desired setting will be confirmed 3 seconds after the operation.
Switch On / Switch Off The Unit (Power button)
- Connect the mains lead to socket.
- Press Power button (A) once to turn on the unit. By default, it runs on Manual Dehumidifying Mode with high fan speed.
- Press Power button (A) once again to turn off the unit. It will stop working, but the fan will work for some seconds to blow out the hot air inside the unit.
Auto shut-off timer function (Timer button)
Press the Timer Button (A) to select your preferred timer hour from 00-24-00.
To cancel the timer function, switch off the unit and switch in on again.
Humidity setting (Manual button)
Press
the Humidity Setting Button (A) to select the desired maximum level of
humidity between the following
CO-30%-35%-40%-45%-50%-55%-60%-65%-70%-75%-80%-CO. CO stands for continuous
non-stop dehumidification regardless of ambient humidity.
At manual mode, all buttons are enabled.
Fan speed option [Fan Speed button] Press the Fan Speed Button (A) to select
your preferred fan speed setting of low and high to meet the different usage
requirements.
Fan Speed Button is disabled at laundry drying mode, auto mode and
defrost mode.
Auto dehumidifying function [Auto button] Press the Auto Button (A) to select the Auto
Dehumidifying Mode.
The unit runs automatically accordance to the ambient humidity detected below.
The Fan Speed Button is disabled in this mode.
Ambient RH% detected | Compressor | Fan Speed Level |
---|---|---|
RH%>65% | Working | High |
55°A.RH%65% | Working | Low |
RH%<55% | Stops Working | Low |
RH = Relative humidity
Multifunction optional [Mode button] Laundry Drying Mode Press
the Mode Button (A) once to select Laundry Drying Mode (B).
The unit runs in continuous dehumidification with high fan speed for 6 hours,
then switch off automatically. The Fan Speed Button is disabled in this mode.
Sleep Mode Press the Mode Button (A) 2 times to select Sleep
Mode (B).
The unit runs with a designated humidity setting of 55% along with low fan
speed.
All indicators will be off 5 seconds after the setting is completed. Touch any
button to activate the light, and to operate as usual. The Fan Speed Button is
enabled in this mode.
After 30 seconds the lights will be off, If no further operation. If the water
tank is full on sleep mode, the full water tank indicator will always be on.
Air Purifying Mode Press the Mode Button (A) 3 times to
select Air Purifying Mode (B).
The unit runs with high fan speed without dehumidifying.
The Fan Speed Button is enabled in this mode.
With the additional purchase of a HEPA filter, the dehumidifier can be
upgraded to a 2-in-1 hybrid model – a combined dehumidifier and air purifier.
With a HEPA filter (extra purchase), you add the possibility of improving the
air quality in the room. A HEPA filter helps against the accumulation of dust,
pollen and other allergens, and reduces allergic reactions. In addition, the
filter removes mold spores, bacteria and viruses from the air. A HEPA filter
can not be washed.
Safety childlock function To prevent the mishandling by young
children, the unit is equipped with a childlock function. Press the Fan Speed
Button (A) for 2 seconds to lock all buttons with a beeping sound. The same
operation can unlock it.
Safety childlock function can be set at standby mode and working mode, but can’t be activated when the water tank is full.
Auto shut off with full water tank indicator When
the water tank becomes full during normal use, the unit will go into standby
mode automatically and the Full Tank Indicator (A) will show. After emptying
the tank, the unit will go on to the previous mode.
Except for the power button, all other buttons are disabled at this state.
If the water tank is removed or not placed properly, the above described will
occur.
Low temperature defrost mode When the ambient temperature is too low, the
dehumidifier will enter into the Defrost Mode. The unit runs with high fan
speed without dehumidifying.
Fan speed button is disabled at this mode.
Memory function
- If the unit is unplugged directly or due to power failure, reconnect the unit to the power supply and the dehumidifier will run with the mode prior to the shutdown. The timer setting will be kept.
- Press the power button to switch off the dehumidifier, and then press the power button to switch it back on. The dehumidifier will run with the mode prior to the shutdown. The timer setting will be canceled.
- Switch off the dehumidifier and unplug the power cord. Then reconnect the power supply and switch on the dehumidifier. It will run as factory preset mode the first time you received the dehumidifier.
Cleaning the dehumidifier
When used regularly, the filter may become clogged with dust and particles. To
ensure the effectiveness of the dehumidifier, it is recommended to clean the
unit at least every two weeks:
Switch the device off and remove the plug from the socket before cleaning.
Clean the housing with a soft, dry cloth. Vacuum clean the air inlet and
outlet grilles of the dehumidifier. If the device is extremely dirty, use a
mild cleaning agent. Wipe the dehumidifier with a slightly damp cloth. Remove
the water tank and wash it by hand using a mild detergent. Rinse it with clean
water
Note: Do not spray water directly onto the unit.
Cleaning and user maintenance shall not be made by children without
supervision.
Cleaning the Pre Filter
-
Remove the pre filter frame from the back.
-
Wash the pre filter frame carefully in warm water, use a mild detergent if necessary. (Max. 40°C)
Note: DO NOT wash the pre filter in a dishwasher. -
Rinse the pre filter in clean water and let it dry before reinserting it.
-
Fit the pre filter frame back onto the unit.
Note: DO NOT use the dehumidifier without the pre filter in place.
Storage
If the dehumidifier will not be used for a long period of time, take the following steps:
- Remove the plug from the socket and empty the tank, make sure the tank and the dehumidifier is completely dry. This may take a couple of days.
- Clean the pre filter.
- Check the dehumidifier for perfect condition to ensure a safe use of it after a long period of storage.
- Pack the device with the suitable packaging.
- Store the dehumidifier in a dust-free location, and out of direct sunlight. Preferably covered with a sheet of plastic.
Display error codes
Please contact our eeese service line if any of the error codes below appears.
DISPLAY CODE | El | E2 | L3 | L4 |
---|---|---|---|---|
Error | The temperature sensor error | The humidity sensor error | The air inlet | |
temperature is too high >42°C | The air inlet temperature is too low <0°C | |||
Display | Flash every 30 seconds | Rash every 30 seconds | Slow flash L3 | Slow |
flash L4
What is happening| The device works normally.| The device works normally, but
can’t set the humidity| The compressor stops working, fan works at low fan
speed. 10 mins later, if the temperature decreases to below 40°C, the device
will work normally| The compressor stops working, fan works at
low fan speed. 10 mins later, if the temperature increases to
above 2°C, the device will work normally.
Trouble Shooting
Check the following before contacting technical support .
PROBLEM | POSSIBLE CAUSE | SOLUTION |
---|---|---|
The dehumidifier will not switch on | The power is not connected | Insert the |
plug into the wall outlet and make sure the power is on
The water tank is full| Empty the tank
The tank has not been replaced correctly| Replace the tank
The set humidity level has been reached| Lower the humidity level
Power plug or cord damaged| Contact an authorized service centre for repair
Water removal capacity is too low| Runtime is too short| Be patient and wait
The ambient temperature or humidity is too low| It is normal that the device
does not dehumidify in these conditions
The device works, but reduces the relative humidity insufficiently| The room
is too big| We recommend using a dehumidifier with a greater capacity
There is too much ventilation| Reduce the ventilation (e.g. close windows and
shut doors)
The air filter is clogged| Clean the Pre-fitter
The humidity is higher than the ambient humidity| Set the humidity lower than
ambient humidity
The humidity is not reducing| The dehumidifier has not been used long enough
The ambient temperature is too low
The surrounding humidity level is too low
The ambient humidity level is lower than the desired humidity level set
The air filter frame is dirty| Clean the pre-filter frame
Dehumidifier is blowing out warm air| The dried air is passed over heating
coils before it is blown into the room as part of the dehumidifying process|
This is normal,
a dehumidifier is not an air cooler
The display is not showing the humidity set point| The display shows the room
relative humidity not the set point| Press the humidity control button once to
see the target relative humidity
Water on floor| There is residual water in tank, and the device is lurched too
much by moving| Be careful when moving the tank
Water in tank overflows| The water tank may be damaged.| Contact our eeese
customer service
Float for water auto-sensor is not in place
Internal drainage passage is blocked or obstructed
The dehumidifier is noisy| The pre-filter is blocked or the device is on an
uneven surface| Clean the pre-filter or put the device on a flat surface
Loose or foreign particles inside the unit| Contact our eeese customer service
Sound of flowing refrigerant
Error code| El: Temperature sensor error
E2: Humidity sensor error| Contact our eeese customer service
Technical Specifications
Model Emma Art. no | 2567 |
---|---|
Max. working area, m2 | 50 |
Recommended working area, m2 | 2-40 |
Wifi | No |
Timer, h | 1 ~ 24 |
IP code | – |
Power Supply | 220-240V – 50Hz |
Dehumidifying Capacity (30°C RH 80%), L/day | 12 |
Dehumidifying Capacity (27°C RH 60%), L/day | 7 |
Power Consumption, W | 160 |
Air Volume m3/h
| High| 95
Low| 75
Noise Level dB(A)
| High| 40
Low| 38
Water Tank Capacity, L| 2,2
Operating Temperature, °C| 5~35
Refrigerant| R290 / 0.045kg
Compressor| Reciprocating
Net Weight, kg| 11
HEPA filter included| No – extra purchase
Pre-filter| Washable
Drain Hose Diameter, mm| 14
Drain hose included (Art. 2558)| No – extra purchase
Product Size (HxWxD), cm| 46,8 × 29,9 × 21
The above technical data are for reference only. We reserve the right to modify them without notice.
Service
If you have any questions or need more information, please feel free to call
eeese customer service on +45 69 16 32 00
If you need service or to make a warranty claim, you must create a case
directly in our support system. Go to the website under SUPPORT.
Warranty
Limited warranty
We guarantee that all parts are free of defects in materials and workmanship
for a period of two years from the date of purchase. The warranty covers only
material or manufacturing defects that prevent the product from being able to
be installed or operated in a normal way.
Defective parts will be replaced or repaired.
The warranty does not cover transportation damage, any use other than what is
intended, damage caused by incorrect assembly or improper use, damage caused
by impact or other error, or by improper storage.
The warranty becomes void if the user modifies the product.
The warranty does not include product-related damage, property damage or
general operational loss.
The manufacturer’s liability cannot exceed the repair or replacement of
defective parts and does not include labour costs to remove and reinstall the
defective part, transportation costs to and from the service center, and all
other materials necessary to carry out the repair.
This warranty does not cover failure or malfunction as a result of the
following:
- Lack of proper installation, operation or maintenance of the unit in accordance with our published “User’s Guide” supplied with the unit.
- The workmanship of any installation of the unit.
- Misuse, alteration, accident, fire, flood, lightning strike, rodents, insects, negligence or unforeseen events.
- Use of non-factory authorised parts or accessories in conjunction with the product.
Limitation of liability
This is the only warranty provided by the manufacturer. No one is authorised
to make any other warranties on our behalf.
This warranty is in lieu of all other warranties, expressed or implied,
including but not limited to any implied warranty of fitness for a particular
purpose and saleability. We expressly disclaim all liability for consequential
damage, accidental damage, indirect loss or loss related to a breach of the
expressed or implied warranty.
This warranty gives you specific legal rights, which may vary by country.
Complaints
In the event of any warranty claim a valid purchase receipt must be presented.
Read about raising a warranty-claim under the SERVICE section.
IMPORTANT!
If you need technical help – contact our eeese service line: eeese DK-
telephone +45 69 16 32 00
We have specialist knowledge of our products and the field in general, so you
can get help quickly and easily.
Responsible Disposal
**** This symbol indicates that this product should not be disposed of with general household waste. This applies throughout the entire EU. In order to prevent any harm to the environment or health hazards caused by incorrect waste disposal, the product must be handed in for recycling so that the material can be disposed of in a responsible manner. When recycling your product, take it to your local collection facility or contact the place of purchase. They will ensure that the product is disposed of in an environmentally sound manner.
Warning on Refrigerant R290
The machine is designed only for use with R290(propane) gas as the designated
refrigerant.
Note: The refrigerant loop is sealed. Only a qualified technician should
attempt to service.
** The lack of smell does not indicate a lack of escaped gas. No open
flames, cigarettes or other possible sources of ignition should be used in the
vicinity of the machine. Component parts are designed for propane and non-
incentive and non-sparking. Component parts shall only be replaced with
identical repair parts.
Note:** The machine may only be installed in a room with a minimum floor
area of 4m2.
R290 is a flammable gas that is heavier than air. On this basis, if the gas
leaks from the unit, the concentration will be the highest at ground level.
However, the gas can be lifted (e.g. by draught, fan, etc) to higher levels.
The R290(propane) used in this unit has no odour. Do not use the machine in a
room with an open flame, other high-level heat sources (e.g. cigarettes,
candles, etc.) or electrical discharges. Install the machine in a room which
can be ventilated when necessary and where gas accumulation is not possible
If R290(propane) is detected in the room, or a leak is suspected, do not allow
unauthorized persons to search for the source of the leak. In such cases,
evacuate all people from the room, open the windows, leave the room and notify
your local fire department to advise them that a propane leak has occurred. Do
not allow any person to return to the room until the commanding officer of the
fire department or a certified service engineer decides that the risk has
ceased to exist.
© All rights eeese air care aps Thank you for choosing this product.
Please read this instruction manual before using it.
eeese air care
info@eeese-aircare.com
Web: eeese-aircare.com
MV-2567-03-2023
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>