Honeywell CS10XE Portable Evaporative Air Cooler User Manual

June 3, 2024
Honeywell

Honeywell CS10XE Portable Evaporative Air Cooler User Manual
Honeywell CS10XE Portable Evaporative Air Cooler

SAFETY RULES

The Air Cooler Guide and User Manual are intended to provide important information needed to set up, operate, maintain and troubleshoot your Air Cooler. Failure to follow these instructions may damage and/or impair its operation, create hazards, and void the warranty. In case there is any inconsistency or conflict between the English version and any other  language version of the content of this material, the English version shall prevail.
WARNING—READ AND SAVE THE AIR COOLER GUIDE AND USER MANUAL
READ AND SAVE THESE INSTRUCTIONS:
When using electrical appliances, basic safety precautions should always be followed:

  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • DO NOT operate with a damaged cord or plug. If the supply cord is damaged, it must be replaced with a supply cord which is as per manufacturers specifications, by the authorized service centre or its service agent or a similarly qualified person in order to avoid a hazard.
  • Before operating the product, remove the packaging and check that product is in good condition.
  • DO NOT allow children to play with this appliance, packaging or plastic bags.
  • Check the household voltage to ensure it matches the appliance’s rating specifications.
  • DO NOT use an extension cord with this unit.
  • DO NOT run power cord under carpeting, or cover it with rugs or runners. Keep the cord away from areas where it may be tripped over.
  • Always ensure the water tank is filled with water above the “min.” level mark, when operating the air cooler in evaporative COOLING mode.
  • Always unplug the Air Cooler before refilling the water tank, cleaning, servicing or relocating the unit.
  • Never pull the cord. Remove it from the electrical outlet/ socket by grasping and pulling on the plug-end of the cord.
  • This appliance has been manufactured for use in domestic environments and must not be used for other purposes.
  • DO NOT use in areas where gasoline, paint or other flammable goods and objects are stored.
  • DO NOT operate the unit on COOL setting with an empty tank as this may result in damage to the water pump.
  • DO NOT attempt to repair or adjust any electrical or mechanical functions of the Air Cooler, as this may void the warranty.
  • DO NOT cover the cooler’s air inlet or outlet, as this may damage the motor.
  • DO NOT insert or allow objects to enter any ventilation or exhaust opening, as this may damage the unit and may cause electrical shock or fire.
  • DO NOT operate with the Honeycomb Cooling Media removed, as this will overload and damage the motor.
  • DO NOT leave the operating appliance unattended for an extended period of time.
  • DO NOT operate this unit if it is damaged or malfunctions. Refer to the Troubleshooting section. If problem still exists contact the Customer Support Center. Always place the unit on a dry level floor.
  • DO NOT use in bathrooms or near water. DO NOT keep the product where it may fall into water or a water container.
  • Store in a dry area when not in use.
  • Always grip the side handles to move the Air Cooler.
  • WARNING: To reduce the risk of fire or electric shock, do not use this appliance with any solid state speed control device.

USER TIPS

What is Evaporative Cooling?

Honeywell Evaporative Air Coolers are built to maximize energy efficiency and keep energy costs low. Warm air is drawn into the cooler and enters the Honeycomb Cooling Media. Water pumped from the water tank pours over the Honeycomb Cooling Media. As the warm air passes through the Honeycomb Cooling Media, the water absorbs the heat, naturally cooling and humidifying the air. A fan propels the cooled air out into the room. This no-compressor system cools naturally, efficiently and inexpensively.

Evaporative Air Cooling Mechanism

INSTRUCTION

The recommended maximum relative humidity level is 60% or less, which allows a noticeable temperature decrease. The temperature will be lower in drier climates because higher evaporation occurs when the humidity is low.

NOTE

When the product is used for the first time the Honeycomb Cooling Media will have an odor which will dissipate in a few hours or so of initial use.

COOLER LOCATION

To maximize efficiency, position the Air Cooler according to the following guidelines:

Indoors

Place the cooler in front of an open door or window. Ensure that there is adequate cross-ventilation in the room by leaving a door or window open opposite the cooler. The Evaporative Air Cooler should not be used in enclosed spaces. It must be kept level and there must be water in the water tank. Doors and windows should be opened to allow free air flow. The Evaporative Air Cooler works best when placed near an open window, so that outside air is drawn into the Evaporative Air Cooler, circulates in the room, then exits via the door. The maximum cooling effect is felt when a person is near the flow of air coming out of the Evaporative Air Cooler. The Evaporative Air Cooler produces moisture and can be used to humidify dry air. To be used for humidification the windows and doors should be closed.

INDOOR

IMPORTANT: The evaporative air cooler is not an air conditioner as it does not use a compressor or refrigerant gas. It should not be expected to cool as efficiently as a refrigerated air conditioner.

Outdoors (for outdoor models only)

  • Use only on GFCI Protected outlets/ sockets (for USA only). Press the TEST button (then RESET button) every month to ensure proper operation.
  • Power cords must be secured to avoid tripping.
  • The wiring and connections must be protected from water. The electrical plug and Air Cooler connections must be dry at all times. When used outdoors, insert the air cooler electrical plug into an IP44 compliant outdoor electrical outlet.
  • Set the unit on a solid flat surface.

IMPORTANT: Honeywell Outdoor Air Cooler models are designed to IPX4 product standards and not recommended to be placed outdoors during heavy rain or snow.

Read the detailed CLEANING & DRAINING THE WATER TANK instructions for your Air Cooler, located in the separate User Manual. Below is a general guideline for maintenance and storage of your Air Cooler.

WARNING: Always switch OFF the Air Cooler and unplug it from the electrical source before cleaning or maintenance.

Cleaning
At least once a week, drain the water tank completely and refill with fresh water. Doing this will greatly reduce mineral deposits and help to extend the life of the Honeycomb Cooling Media.

End of Season Storage
If the Air Cooler will not be used for a long time:

  • Make sure all parts are dry by running the Fan Only mode for about 1 to 2 hours before storing (time depends on ambient humidity conditions).
  • Switch OFF the Air Cooler and unplug from the power supply.
  • Empty/drain all the water from the tank. Note: If the unit is connected to a continuous water supply, you must switch off the water supply and remove the drain tube before draining the water tank. This function is only available on some Honeywell Air Cooler models. Check the User Manual to see if your unit has the Continuous Water Supply Function.
  • Clean the water tank with a damp cloth to wipe away any dust or mineral deposits.
  • Remove the Honeycomb Cooling Media and Carbon Dust Filter* from the Air Cooler and rinse under fresh water to remove dust and dirt.
  • Replace the Honeycomb Cooling Media and Carbon Dust Filter* after they are clean and dry.
  • To protect the unit from dust, moisture and scratches, cover with a clean cloth, tarp or plastic bag before storing.
  • Coil the power cord and store it away from the floor to protect it.
  • Store this unit at room temperature in a dry location, away from direct sunlight and/or very hot, cold or damp environments.
  • Carbon Dust Filter is available in specific models of Honeywell Air  Coolers only. Check the Parts Description in the User Manual for your model to see if it includes a Carbon Dust Filter.

TROUBLESHOOTING GUIDE

PROBLEM POSSIBLE CAUSE SOLUTION

No discharge of air.

| Cord is not plugged in.| Make sure power cord is plugged in and the switch is ON.
Power is not ON.| Turn the unit ON by pressing the power button on the control panel / remote control or turn the SPEED knob.

Not Cooling / Unit is making noise.

| Pump is not turned ON.| Turn on COOL function from remote or control panel.
Low or no water in tank, when COOL is selected.| Refill water tank.
Damaged Pump or Calcium deposits on blower.| Contact Customer Service Center.

Excessive humidity in the room.

|

In cooling mode, the Air Cooler produces moisture as a result of evaporative cooling. This is normal.

| The Air Cooler cools best in dry climates. If the ambient humidity level is high (approx. 60% or above), refrain from using the Air Cooler until ambient humidity is reduced.
Make sure the window/doors are open and there is adequate cross-ventilation in the room so thatthe moisturized air can circulate better. Do not use the evaporative cooling function on days with high ambient humidity.

Odors.

| When the Cooler is new.| When the unit is used for the first time, the Honeycomb Cooling Media will have an odor, which will dissipate within a few hours of initial use.

Algae or mold due to moist parts. In very damp conditions, algae may form.

|

Check the Honeycomb Cooling Media. If you see mold spots on the media or suspect an algae issue, remove and replace the Honeycomb Cooling Media. Contact the Customer Service Center for more information.

PROBLEM POSSIBLE CAUSE SOLUTION
**** Remote control does not work. **** Remote control
batteries are old & used or inserted incorrectly in the battery compartment.

**** Replace with new batteries. Follow the polarity guide inside the battery compartment.
Damaged remote control.| If replacing new batteries in the correct position does not work, contact the Customer Service Center.
**** The unit does notrespond.| **** Damaged Control Panel on unit.| Try to activate the unit with the Remote Control. If the unit responds, then the Control Panel on the unit may be experiencing problems – contact the Customer Service Center.
If neither the Remote Control or the Control Panel is working, contact the Customer Service Center.
**** The outdoor Air Cooler is wet from rain.| **** The Air Cooler was placed outdoors (this is only allowed for outdoor Air Cooler models) and soaked by heavy rain.| A small amount of rain on the unit is not a problem as long as the electrical plug and outlet are dry. If they are wet, DO NOT touch the unit or electrical plug/ outlet. Switch off the master power for the outlet before unplugging the unit from the electrical outlet. Make sure all outlets and plugs are dry before use.
****
The Air Cooler is designed to IPX4 product standards and not recommended to be placed outdoorsduring heavy rain conditions. Do not operate the Air Cooler when wet. Wait for the Air Cooler to dry before plugging in and turning on the unit again.

The batteries contain materials, which are hazardous to the environment; they must be removed from the appliance before it is scraped and that they are disposed of safely

Correct Disposal of this product.
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal. recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.

PARTS DESCRIPTION

PRODUCT OVERVIEW

  1. Display Screen
  2. Control Panel
  3. Water Level Indicator
  4. Detachable Water Tank Latch
  5. Louvers
  6. Front Grill
  7. Handle
  8. Honeycomb Cooling Media
  9. Rear Grill
  10. Water Fill Tray
  11. Water Tank
  12. Castors
  13. Remote Control
  14. Carbon Dust Filter
  15. Power Cord & Plug
  16. Drain Plug

WARNING — READ AND SAVE THE AIR COOLER SAFETY &  MAINTENANCE GUIDE AND USER MANUAL BEFORE USING THIS PRODUCT. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY DAMAGE AND/ OR IMPAIR ITS OPERATION AND VOID THE WARRANTY. IN CASE THERE IS ANY INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH VERSION AND ANY OTHER LANGUAGE VERSION OF THE CONTENT OF THIS MATERIAL, THE ENGLISH VERSION SHALL PREVAIL.

CONTROL PANEL

CONTROL PANEL

FUNCTION BUTTONS

POWER
Press the POWER button to turn the unit on. The cooler will start automatically at medium speed. After a few seconds the speed will switch to low. To turn the unit off, press the button again.
SPEED
Press the SPEED button repeatedly to change the speed between H – M – L.
TIMER
Press the TIMER button until the desired time duration setting is selected. When the set time has passed, the unit will automatically turn off (unit remains in Standby mode until power cord is unplugged from electrical socket). The TIMER function allows you to program the unit for up to 7.5 hours of use.
COOL
Press the COOL button until is illuminated on the display screen. This activates evaporative\ cooling. The water pump will operate and you will feel the cooler air after the Honeycomb Cooling Media is completely wet.
WARNING: Please ensure sufficient water is in the water tank otherwise you may hear a Low Water Alarm and the cooler will start in a Fan only mode without evaporative cooling.
SWING

Press the SWING button until is illuminated on the display. The louvers will begin to move left to right automatically. Vertical Air Flow – You can manually adjust the louvers to change vertical air flow.

REMOTE CONTROL

POWER :ON / OFF

SPEED; Low / Medium / High

COOL:   Evaporative Cooling ON / OFF

SWING: Controls the motion of the louvers

TIMER: Controls the Timer function for automatic off

NOTE

  • The remote control requires a CR2032 (1 x 3V) coin type or equivalent battery for replacement.
  • Open the battery compartment at the back of the remote control and insert the battery inside. Care must be taken to insert the batteries according to the correct polarity (+ / –) markings shown inside the battery compartment.
  • Always point the remote control signal transmitter towards the unit when operating. Make sure that the signal path is not obstructed.
  • Remove the batteries if the unit is not going to be used for an extended period of time.
  • Do not drop the remote control.
  • Do not mix different types of batteries such as alkaline, carbon-zinc, or rechargeable batteries.
  • Do not mix old and new batteries.
  • Do not recharge the battery.
  • Exhausted batteries are to be removed from the product and safely disposed of as per local regulations.
  • Do not dispose of batteries in fire. Batteries may explode or leak.
  • This product contains a lithium button/coin cell battery. If a new or used lithium button/ coin cell battery is swallowed or enters the body, it can cause severe internal burns and can lead to death in as little as 2 hours. Always completely secure the battery compartment. If the battery compartment does not close securely, stop using the product, remove the batteries, and keep it away from children. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.
  • The batteries shall be disposed of properly, including keeping them away from children.
  • Even used batteries may cause injury

WARNING: Chemical Burn Hazard. Keep batteries away from children.

COOLER LOCATION

Make sure to position the air cooler correctly before you set up and start using the product. Please refer to the COOLER LOCATION section of the separate Safety & Maintenance Guide.

FILLING WITH WATER

CAUTION

Unplug the unit from the electrical power outlet before emptying or refilling the water tank. Open the Water Fill Tray located at the back of the unit. The Water Level Indicator is located at the side of the unit. Refill the water tank when water level is low. Do not fill water above the “Max.” water level mark to avoid water droplets collecting on the louvers. Check the water level in the tank before running the COOL function. Make sure that the water in the tank is above the minimum water level mark. Running the unit in COOL mode with inadequate water may cause pump failure.
Note: The water capacity refers to the total volume of water that can be contained within the air cooler water tank and water distribution system. The water capacity in the tank at the “Max.” indicator level may be lower than the actual water capacity of the air cooler.
WARNING: Do not fill water tank with dirty water or salt water. This can damage the unit and Honeycomb media.

LOW WATER ALARM

The unit is equipped with a low water sensor. In Cooling Mode, when water in the tank is below the minimum level, you will hear a beeping sound and the will flash continuously. The unit will automatically pause evaporative cooling. Refill the water tank to deactivate the alarm in cooling mode. First switch OFF the unit and unplug from the power outlet. Fill the water tank with water above the minimum water level mark. Plug in and switch ON again. To deactivate the alarm and continue using the unit as a fan (without evaporative cooling), switch the unit OFF and then ON again. The Low Water Alarm will not activate in Fan only mode. The Low Water Alarm will sound again if the COOL function is activated while the water tank is still empty.

CLEANING & DRAINING THE WATER TANK

Below are instructions on how to clean and maintain your air cooler. If the cooler will not be used for a long period of time, please refer to the STORAGE & MAINTENANCE GUIDELINES located in the separate Safety & Maintenance Guide.

WARNING:
Before cleaning the unit, switch the unit OFF and disconnect from the electrical socket

  • Move the unit to a location where the water can be drained. Remove the cap from the Drain plug located at the bottom of the unit. Allow the tank to empty.
  • Detach the water tank by unlocking the Detachable Water Tank Latches on both sides of the unit. Lift the cooler upwards away from the base and place it carefully and vertically on the floor. Be careful not to bend the water pump tubes and other parts that will hang from the bottom of the unit when the body is removed from the tank.
  • Refill the water tank with clean water and drain it completely. Clean the water tank with dish detergent or a damp cloth and rinse it thoroughly.
  • Refill the water tank with clean water, up to the maximum level.
  • Replace the top of the air cooler carefully back onto the tank and lock the side latches. The air cooler is now ready to be used.
  • Use a damp cloth to remove dirt and dust from the surface of the unit. Never use corrosive elements or chemicals to clean this product.
  • When the product is not in use, store the unit in a dry place out of direct sunlight.

CLEANING THE CARBON DUST FILTER AND HONEYCOMB COOLING MEDIA

  • The appliance is supplied with a Carbon Dust Filter and Honeycomb Cooling Media.
  • The Carbon Dust Filter and Honeycomb Cooling Media are located inside the Rear Grill. See Figure 1 for instructions on how to remove them from the unit for cleaning and maintenance.
  • Do not run the unit in COOL mode with stale water in the tank. You must empty the water tank and refill with fresh water, especially if the tank has not been cleaned in a long time.
  • The cleaning frequency for the Honeycomb media depends on local air and water conditions. In areas where the mineral content of water is high, mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow. Draining the water tank and refilling with fresh water at least once a week will help reduce mineral deposits. If mineral deposits remain on the Honeycomb Cooling Media, the media should be removed and washed under fresh water. The media should be cleaned every two months or sooner, depending on your needs.
  • For best results allow the Honeycomb Cooling Media to dry after each use by turning off the cool function 15 minutes before turning the unit off.

Removing the Carbon Dust Filter/ Honeycomb Cooling Media:
INSTRUCTION

  1. Remove all the screws from the Rear Grill of the Air Cooler.
  2. Carefully pull out the rear grill from the cooler.
  3. Slide out the Carbon Dust Filter and clean with water.
  4. To release the Honeycomb Media, remove the Honeycomb Frame screws and pull the Honeycomb Frame out of the unit.
  5. Remove the screws on the base of the Honeycomb Frame and slide out the Honeycomb Cooling media. Replace or clean media with water and a damp cloth as needed.

WARNING:
DO NOT operate the Air Cooler when the Rear Grill is removed from the Air Cooler, or if there is a loosefitting Rear Grill. Doing so can cause serious injury or dangerous electrical shock.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals

Related Manuals