WELLFOR DK MCA2330 BL Medicine Cabinet

READ THE INSTRUCTIONS CAREFULLY, and familiarize yourself with all the parts as shown in the exploded view. The exploded view will also provide a helpful reference when relating to the location of the various parts and how they are mounted.

WELLFOR DK MCA2330 BL Medicine Cabinet - fig

20″ Height series=2 shelf kits+ 0 decorative cover
24″ Height series=2 shelf kits+ 4 decorative cover
26″ Height series=2 shelf kits+ 6 decorative cover 30″
Height series=3 shelf kits+ 4 decorative cover 36″
Height series=3 shelf kits+ 8 decorative cover

PARTS LIST.

WELLFOR DK MCA2330 BL Medicine Cabinet - parts list

WARNING: Safety glasses should always be worn when working with a medicine cabinet
RECOMMENDED TOOLS

WELLFOR DK MCA2330 BL Medicine Cabinet - fig1

Determining Measurement and Direction:

Model No. Height Width Depth Tolerance
1620 191/2″ 151/2″ 4″ ±1/8″
1224 23 1/2″ 111/2″ 4″ ±1/8″
1524 23 1/2″ 14 1/2″ 4″ ±1/8″
2026 25 1/2″ 19 1/2″ 4″ ±1/8″
1930 29 1/2″ 18 1/2″ 4″ ±1/8″
2330 29 1/2″ 22 1/2″ 4″ ±1/8″
1536 35 1/2″ 14 1/2″ 4″ ±1/8″

WELLFOR DK MCA2330 BL Medicine Cabinet - fig2

If needed, please turn over the upside to the downside, you may get the opposite hand installations.

WELLFOR DK MCA2330 BL Medicine Cabinet - fig3

Recessed or semi-recessed

  1. Pull off the side kits from the cabinet as the figure shown.WELLFOR DK MCA2330 BL Medicine Cabinet - fig4
  2. Make sure hinges are on the correct side of the opening for left-hand or right-hand operation. Place the cabinet box into the rough opening. On fully recessed applications, make sure the cabinet flange covers the rough opening evenly all around (Fig 3). In semi-recess applications, mirror edges should meet the wall surface. (Fig 4). Shim as needed.WELLFOR DK MCA2330 BL Medicine Cabinet - fig5
  3. Insert four (4) #10 x 11/2″ screws into four locations provided for recessed installation (Fig 5). Be careful not to overtighten. Make sure the cabinet is centered in a rough opening. Cover screws with provided caps 10WELLFOR DK MCA2330 BL Medicine Cabinet - fig6

How to Surface Mount Cabinet

If installing in combination with a middle mirror/shelf kit, please see the “Center Mirror/Shelf Kit Installation” Directions that came with your center mirror prior to performing the steps below

  1. Establish precise height and draw a level horizontal line (Fig 6). IMPORTANT: Detect the medicine cabinet at a precise height. Make sure there is at least 1″ of clearance above any obstructions.WELLFOR DK MCA2330 BL Medicine Cabinet - fig7
  2. Place the bottom of the wall bracket on the horizontal line and at the correct position left to right and mark holes on the wall (Fig 7).
  3. Drill 8 mm hole if required for wall anchor and place wall anchor in hole. Mount wall bracket with #10 x 11/2″ e screws. (Fig 8)WELLFOR DK MCA2330 BL Medicine Cabinet - fig9
  4. Insert surface mount z-clips as shown (Fig 9 & 10).WELLFOR DK MCA2330 BL Medicine Cabinet - fig10
  5. Place cabinet into wall bracket (Fig 11). Mark hole locations of z-clips (Fig 12). When determining location, it is recommended that at least one z-clip be located at a stud. Detach cabinet and drill 8mm hole if needed for anchor, and place in anchor in hole.WELLFOR DK MCA2330 BL Medicine Cabinet - fig11
  6. Remount cabinet and connect with #10 x 1 112″ 6 screws (Fig 13). Be careful not to damage or scrape the top flange

Door Installation

  1. Remove protective packaging from the door, and be careful not to bump the edges of the mirror. Line hinges up against hinge mounting plates. Snap into position (Fig 14).WELLFOR DK MCA2330 BL Medicine Cabinet - fig12
  2. The door should “snap” locked when about 1″ from being fully closed. The door should be placed even in relation to the cabinet.WELLFOR DK MCA2330 BL Medicine Cabinet - fig13

Limit Clips

Limit Clips 14 are provided should you need to reduce the opening swing of the cabinet door from 170 degrees to 130 degrees (see top view) This will eliminate the possibility of the door hitting a wall sconce or other decorative items.WELLFOR DK MCA2330 BL Medicine Cabinet -
fig14

Additional Item Installation

  1. Insert dear shelf clip 0 into the appropriate hole location using 2 clips per shelf (Fig 16).
  2. Place glass shelf® on top of dear shelf clips making sure the shelf is against the back of the cabinet. Press lightly to adhere to the shelf clip sticker (Fig 17).
  3. Fill remaining holes with hole plugs® (Fig 18). Fill the rest of the shelf dip holes with decorative covers 0 (Fig 19).

WELLFOR DK MCA2330 BL Medicine Cabinet - fig19

COVER PLATE(2pcs)

WELLFOR DK MCA2330 BL Medicine Cabinet - fig20

Pasting Nameplate

  1. After the door and cabinet are installed, install name plates by peeling protective plastic from the door and back of the nameplate, then placing the nameplate in the proper location (Fig 26)
    WELLFOR DK MCA2330 BL Medicine Cabinet - fig21