WELLFOR 48 X 30 Bathroom Mirror Medicine Cabinet with Light Installation Guide

June 1, 2024
WELLFOR

WELLFOR 48 X 30 Bathroom Mirror Medicine Cabinet with Light

WELLFOR-48-X-30-Bathroom-Mirror-Medicine-Cabinet-with-Light-product-
image

NIKA-W3MCL4830
LIGHTED MEDICINE CABINET Lighting and Defogger

INSTALLATION

PRODUCT SERIES INFORMATION

*WARNING: Do not remove corner proctors & paper cushions, please remove after installation. Please retain the cabinet accessories during the installation process for future needs, for example, screws, nuts, cap and other similar components. Requires three(3) person in installation.

Style and shape may vary from the picture above. Instructional purpose only

IMPORTANT SAFETY INSTRUCTIONS

When using an electrical furnishing, basic precautions should always be followed, Requires three(3) person in installation.

  • DANGER
    READ AND FOLLOW ALL INSTRUCTIONS BEFORE USING THIS MIRROR CABINET

  • WARNING
    To reduce the risk of burns, fire, electric shock or injury to persons. Use this furnishing only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer. Never drop or insert any object into any opening. Do not use outdoors.

  • WARNING
    Risk of electric shock. Connect this furnishing to a properly grounded circuit only. See Grounding instructions.

GROUNDING INSTRUCTIONS:

WARNING
This product must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the product.
An Electrical option cabinet must be wired to a 20 Amp GFI (Ground Fault Interrupter) protected circuit when used in bathrooms and all other locations required by the National Electric Code.

NOTE: To ensure the normal use of product, it is required to set out wires as per the regulations of IEE. The prod­uct is only applicate to the indoor installation. The installation must be executed by a professional electrician, wrong installation may lead to product damage and personal injury.
PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE  ALL RIGHTS RESERVED

ELECTRIC CONNECTIONS

ALL WIRING SHOULD BE DONE BY A QUALIFIED LICENCED ELECTRICIAN

  • WARNING: Shut off power before wiring the mirror.
  • WARNING: An Electrical option mirror must be wired to a 20 Amp GFI (Ground Fault Interrupter) protected circuit when used in bathrooms and all other locations required by the National Electric Code.
  • WARNING: This mirror must be connected to a grounded, metal permanent wiring system or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the mirror.
  • CAUTION: Requires 120 VAC 20 Amp GFI protected circuit.
  • Electric wiring: Be sure to provide enough wire to make the proper and safe connection to the Field/Power.

WIRING DIAGRAM

MIRROR FEATURES

  • Copper free silver mirror
  • High output LED lighting: CRI 90+,3000-6000K CCT, IP44
  • Color Temperature changing
  • Light Brigheness changing
  • Recess mount or wall surface mount
  • Defogger

TOOLS REQUIRED FOR ASSEMBLY

WELLFOR-48-X-30-Bathroom-Mirror-Medicine-Cabinet-with-Light-
\(6\)

PARTS INCLUDED

WELLFOR-48-X-30-Bathroom-Mirror-Medicine-Cabinet-with-Light-
\(7\) NOTE: Determine overall mirror dimensions before installation.
Requires three(3) person in installation.
Accessories and parts may vary from the picture above. Depends on the product model and size.

DIMENSIONS

WELLFOR-48-X-30-Bathroom-Mirror-Medicine-Cabinet-with-
Light-38NOTE: All rough-in dimensions for reference only!

NOTE: Please use rough in size for recess mounting installation(wall cut- out).
All dimensions and specifications are nominal and may vary.Use actual products for accuracy in critical situations.
Style and shape may vary from the picture above. Instructional purpose only

SURFACE-MOUNTED INSTALLATION

  • No need to take off the door(s) before installing the cabinets.

    1. Level and mark the cabinet’s location on the wall.
    2. Mark the position of the Bottom Mounting Bracket and Punch. WELLFOR-48-X-30-Bathroom-Mirror-Medicine-Cabinet-with-Light- \(9\)
    3. Punch holes in the mark, put in Wall Plug, fix Bottom Mounting Bracket to the wall with Screw
    4. With assistance, to rest the cabinet on the mounting bracket and hold in place.
    5. Insert top mounting bracket into the top of the cabinet.
    6. Make sure top brackets are locked in the grooves.
    7. Adjust the position of Top Mounting Bracket and mark the holes with a pencil
    8. Remove the cabinet, drill holes according to the marked position, and put in Wall Plugs.
    9. Put the cabinet on the bottom mounting bracket and hold the place, then insure the top mounting bracket into the top of cabinet, fix the top mounting brackets to the holes with screw.(repeat step 4-6)
    10. Test the fit of the cabinet before Final assembly.
    11. Peel off the stickers from the EVA foams and metal blocks, Affix the mirror panel to the side of the cabinet, gently press the mirror panel with your hands until it adheres firmly.
    12. Wiring the power line.
      WARNING: Turn off the power before wire connection!

RECESS INSTALLATION

  • No need to take off the door(s) before installing the cabinets.

    1. Detach side mirror connectors and EVA foam pads from the cabinet for recessed installation. These items are located on both sides of the miror cabinet body. 

    2. Refer to “dimensions” on page 4 to measure Rough in size. WELLFOR-48-X-30-Bathroom-Mirror-Medicine-Cabinet-with-Light- \(21\)

    3. Draw the perimeter of the cabinet on the wall.

    4. Cut the hole as marked dimension with suitable tool.

    5. Frame the opening for the cabinet based on the measurements.

    6. First cut off the power, then use the WIRE CONNECTOR connect to external power supply.
      WARNING: Turn off the power before wire connection!

    7. Connect electrical wires and then place the cabinet between the wall studs.

    8. Affix using hardware screws into the studs.
      NOTE: For wood stud wall,you need to use screw to fix the cabinet. For brick/concrete/stone/tile wall, you need to use wall plug and screw together to fix the cabinet.

GLASS SHELF ADJUSTMENT

  • Remove the Door(s) before adjusting cabinet shelves.

    1. Insert the metal glass shelf clips into the shelf holes on both sides of the mirror cabinet.
    2. Insert the Glass Shelf along the board clip slot.
    3. Use a Phillips screwdriver to tighten the screw at the bottom of the metal shelf clip, securing and clamping the glass shelf in place.

MIRROR DOOR INSTALLATION

  1. Slide the doors into place by pinching the end of the hinges.
  2. Plug the door into the cabinet.
    Press the end of the hinge to match the hinge seat
    Installing wiring terminals WELLFOR-48-X-30-Bathroom-Mirror-Medicine-
Cabinet-with-Light- \(29\)

Door Adjustment / Door Removal

OPTIONAL DOOR ADJUSTMENT
Doors may need to be adjusted after the initial shipping of the cabinet. The cabinet doors have a three-way adjustment feature. Height, side-to side, level and depth can be adjusted. With the hinge slightly closed you can access the middle screw for up/down adjustment.
With the hinge fully extended you can access the front and back screws. These screws will move the door side to side and in and out. WELLFOR-48-X-30
-Bathroom-Mirror-Medicine-Cabinet-with-Light- \(30\)

TOUCH BUTTON AND OUTLET CHARGER

How to use Defogger Switch and Dimmer Switch :

Left Touch Sensor
Short touch to turn ON/OFF the defogger.
Middle Touch Sensor Short touch to ON/OFF lighting.

Right Touch Sensor
Short touch to get the light temperature 6000K, 4000K and 3000K. Long touch to adjust the light brightness from 10°/o-100°/o. Release the button when the light reaches the desired setting.

*Suggestion: The mirror is equipped with memory function to preserve the previous brightness/color settings.

How to use Outlet and USB Charger :
This lighted medicine cabinet contains outlet and USB chargers.

  1. Outlet Charger is 15Amp 110V AC to power shavers, or toothbrushes, but do not use it for Hair dryer, it may blow a circuit.
  2. USB ports provide 4.2Amp 5V DC for charging purpose only, not for data transfer.

*Suggestion: Turn off the mirror power supply if you don’t use it for a long time.

*The design of touch switch may vary, and subject to change without prior notice.

USE AND MAINTENANCE

WARNINGS :

  1. Please do not use if you found the mirror cabinet has been broken.
  2. Never put any sharp or heavy material on the mirror surface, other wise the glass mirror will be broken and body injury accidents may occur .
  3. Turn off the power switch in storm lightning weather to avoid electric parts damage.

Use and Maintenance:

CAUTION:

USE

  1. To avoid damage, do NOT knock the mirror cabinet with any hard objects; CLEANING
  2. Do NOT clean the mirror cabinet with caustic cleaner. Do NOT wipe the mirror cabinet with Bristle brush; MAINTENANCE
  3. For daily maintenance, please use soft cloth and mild cleaner to clean the mirror cabinet.

LIMITED WARRANTY

LIMITED WARRANTY TWO YEARS TERM:
®WELLFOR warrants to the original purchaser that, it will, at its election repair, re­place, or make appropriate adjustments to products made by this company shown to have significant defects in material or workmanship which are reported to ®  WELLFOR in writing within two (2)years from the date of delivery. WELLFOR® is not responsible for installation costs. The warranty is void in the event the product is damaged in transit, or if damage or failure is caused by abuse, misuse, abnor­mal usage, faulty installation, damage in an accident, improper maintenance, or any repairs other than those authorized by WELLFOR At the expiration of the two years warranty period, WELLFOR® shall be under no further obligation under any warranty, expressed or implied, including the implied warranty of merchantability. ® WELL FOR shall not be liable for any consequential damages arising out of or in
connection with the use or performance of its products. Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Any liability against WELLFOR® under any implied warranty, including the warranty of merchantability, is expressly limited to the terms of this warranty. Permission to return any merchandise under this warranty must be authorized by WELLFOR and returned prepaid by the purchaser. Claims under this warranty should be sent directly to your dealer.

For customer support please call 206.809.0093 weekdays 9:00 to 6:00 PST, or by email: service@wellfor.com.
For more information: www.wellfor.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

WELLFOR User Manuals

Related Manuals