WELLFOR ERIC-M1FM4032 LED Mirror Medicine Cabinet Instruction Manual

June 1, 2024
WELLFOR

WELLFOR ERIC-M1FM4032 LED Mirror Medicine Cabinet

Specifications:

  • Model Numbers: ERIC-M1FM4032, ERIC-M1FM4836, ERIC-M1FM5530, ERIC-M1FM6028, ERIC-M1FM7236, ERIC-M1FM8442
  • Colors/Finishes: Matte Black (MB), White (WT)
  • Requires two (2) persons for installation
  • Ground Fault Interrupter (GFI) protection required for bathroom use

Product Usage Instructions

Placement:

Select the desired position of the mirror. Ensure it is level and mark the location. The mirror can be mounted vertically or horizontally.

Support Location:

Measure the hanging bar holes and mark the drilling locations to ensure proper alignment. Make sure the markings are leveled.

Install Screws:

Using a drill, make holes on a solid wall. Fill the holes with the supplied plugs and securely screw them into the hanging bar holes.

Power Off:

Before connecting the mirror wires, ensure all power is turned off.

Connection:

Plug into the socket or cut off the plug and use the wire connector to connect to an external power supply. You have plug or hardwire connection options.

Turn On the Power:

Once the mirror is hung up stably, turn on the power. Make sure to connect Live to black, Neutral to white, and Ground to green.

Cleaning and Maintenance:

  1. Avoid knocking the mirror with hard objects.
  2. Do not use caustic cleaners or bristle brushes on the mirror.
  3. For daily maintenance, clean the mirror with a soft cloth and mild cleaner.

Limited Warranty:

For customer support, call 206.809.0093 on weekdays from 9:00 to 6:00 PST or email service@wellfor.com. Visit www.wellfor.com for more information.

FAQ

Q: Can I use this mirror outdoors?

A: No, this mirror is not designed for outdoor use.

Q: What should I do if the mirror fogs up?

A: The mirror comes with a defogger. Turn it on to clear any fogging.

Q: Is it safe to connect the mirror to a plug & socket outlet?

A: No, it is recommended to hardwire the mirror to ensure safety. Do not connect the hardwire to a plug & socket outlet.

IMPORTANT SAFETY INSTRUCTIONS

When using an electrical furnishing, basic precautions should always be followed,Requires two(2) person in installation.

  • DANGER
    READ AND FOLLOW ALL INSTRUCTIONS BEFORE USING THIS MIRROR.

  • WARNING
    To reduce the risk of burns, fire, electric shock or injury to persons. Use this furnishing only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer. Never drop or insert any object into any opening. Do not use outdoors.

  • WARNING
    Risk of electric shock. Connect this furnishing to a properly grounded circuit only. See Grounding instructions.

GROUNDING INSTRUCTIONS

WARNING
This product must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the product.
An Electrical option cabinet must be wired to a 20 Amp GFI (Ground Fault Interrupter) protected circuit when used in bathrooms and all other locations required by the National Electric Code.

NOTE: To ensure the normal use of product, it is required to set out wires as per the regulations of IEE. The product is only applicate to the indoor installation. The installation must be executed by a professional electrician, wrong installation may lead to product damage and personal injury.
PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE ALL RIGHTS RESERVED

ALL RIGHTS RESERVED

TOOLS REQUIRED FOR ASSEMBLY

PARTS INCLUDED

HARDWARE INCLUDED (not shown actual size)

NOTE: Determine overall mirror dimensions before proceeding to installation.
All dimensions & specifications are approximate and subject to change without notice.
Accessories and parts may vary from the picture above.Depends on the product model and size.

ELECTRIC CONNECTIONS

ALL WIRING SHOULD BE DONE BY A QUALIFIED LICENCED ELECTRICIAN

  • WARNING: Shut off power before wiring the mirror.
  • WARNING: An Electrical option mirror must be wired to a 20 Amp GFI (Ground Fault Interrupter) protected circuit when used in bathrooms and all other locations required by the National Electric Code.
  • WARNING: This mirror must be connected to a grounded, metal permanent wiring system or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the mirror.
  • CAUTION: Requires 120 VAC 20 Amp GFI protected circuit.

Electric wiring: Be sure to provide enough wire to make the proper and safe connection to the Field/Power.

MIRROR FEATURES

  • 5mm copper free silver mirror
  • High quality LED Lighting
  • CRI 90+, 3000-6000K CCT, IP44
  • Color temperature and dimming
  • Separate controlled defogger
  • Vertical and horizontal mount options

INSTALLATION INSTRUCTIONS

  1. PLACEMENT
    Select the desired position of the mirror. Level and mark the location.
    (vertical and horizontal mounting opntions)

  2. SUPPORT LOCATION
    Measure the hanging bar holes and mark the drilling locations ensure marking are leveled.

  3. INSTALL SCREWS
    Using a drill, make holes on solid wall,and fill with supplied plugs and screws into hanging bar holes tightly.

  4. POWER OFF
    Please turn off all the power before the mirror wires connection.

  5. CONNECTION
    Plug into the socket ,or cut off the plug then use the wire connector to connect the external power supply.(plug or hardwire connection options)

  6. Turn on the power
    Hang up the mirror stable then turn on the power.

TOUCH SWITCH SETTING UP

How to use Touch Switch:

The mirror is equipped with memory function to preserve the previous brightness/color settings.
*Suggestion: The mirror is equipped with memory function to preserve the previous brightness/color settings.

WARNINGS:

  1. Please do not use if you found the mirror have been broken.
  2. Never put any sharp or heavy material on the mirror surface, otherwise the glass mirror will be broken and body injury accidents may occur.
  3. Turn off the power switch in storm lightning weather to avoid electric parts damage.

Use and Maintenance

CAUTION

LIMITED WARRANTY

LIMITED WARRANTY TWO YEARS TERM:

WELLFOR warrants to the original purchaser that, it will, at its election repair,replace, or make appropriate adjustment to products made by this company shown to have significant defects in material or workmanship which are reported to WELLFOR in writing within two (2)years from the date of delivery.WELLFOR is not responsible for installation costs. The warranty is void in the event the product is damaged in transit, or if damage or failure is caused by abuse, misuse, abnormal usage, faulty installation, damage in an accident,improper maintenance,or any repairs other than those authorized by WELLFOR.At the expiration of the two years warranty period,WELLFOR shall be under no further obligation under any warranty, expressed or implied,including the implied warranty of merchantability. WELLFOR shall not be liable for any consequential damages arising out of or in connection with the use or performance of its products. Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.Any liability against WELLFOR under any implied warranty, including the warranty of merchantability, is expressly limited to the terms of this warranty. Permission to return any merchandise under this warranty must be authorized by WELLFOR and returned prepaid by the purchaser. Claims under this warranty should be sent directly to your dealer.

For customer support please call 206.809.0093 weekdays 9:00 to 6:00 PST, or by email: service@wellfor.com.
ALL RIGHTS RESERVED
For more information: www.wellfor.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

WELLFOR User Manuals

Related Manuals