TRIAX TWB 40 Wideband LNB User Manual
- June 3, 2024
- TRIAX
Table of Contents
TRIAX TWB 40 Wideband LNB
The installation and commissioning may only be performed by suitably qualified persons, technicians or installers in compliance with safety regulations like EN 62368-1 and EN 60728-11. Pay also attention to the specific safety instructions and advices you find in this user manual! Failure to comply with the specified precautionary measures may cause serious injury to persons or damage to property. Damage due to improper installation and commissioning, defective connectors on cables or any other incorrect handling will void the warranty.
Disconnect mains power before working on electrical systems.
- Any additional electrical wiring requirements should always be installed by a suitably qualified person(s).
- Installation or service work should NEVER be undertaken during electrical / thunderstorms.
Waste Electrical and Electronic Equipment (WEEE) after end of life
- Do not dispose of these products in household waste! Dispose of them for recovery and recycling following the current National and European legislation and regulations.
Introduction
The purpose of this guide is to enable the successful installation of the TRIAX SAT Fibre Optic System, utilizing the OTX at the headend. Please read and follow the advices comprehensively.
Functional description
The Wideband LNB TWB 40 is preferred for using with the TRIAX SAT Fibre Optic Transmitter OTX in order to utilize the SAT FO Headend fibre optic distribution networks. The LNB is designed with two fixed SAT-IF wideband outputs with F-female connectors. The LNB is voltage supplied by the OTX transmitter via V- port (+12V) and the H-port (+20V).
Wideband LNB TWB 40 connection with SAT Fibre Optic Transmitter OTX
Specific safety instructions
- The installation is carried out by a competent person.
- A site survey has been completed; the location for the dish has been chosen and the dish has been installed to comply with the user manual of the dish and with the safety requirements of EN 60728-11, especially in terms of grounding of the dish and mast.
- Fasten all screws to fix the dish and LNB when mechanical adjustments for best reception have been solved.
Installation
- Mount the LNB into the feed holder of the dish. Firstly do fasten the screw only slightly.
- Connect an SAT-IF level meter with DC supply 18V to H- or 13V to V-port of the LNB.
- Align the dish to the wanted Satellite position by reaching the top output level on the level meter.
- Adjust the position of the LNB by a slight rotation of the LNB to + or – in order to get the highest cross-polarization rejection and MER value on the level meter. Fasten all screws to fix the dish and LNB finally.
- Connect the coaxial patch cables to the OTX (aware: H-H and V-V).
- The coaxial cable connectors should be waterproofed e.g. by gel boot and amalgamating tape.
Appendix
Mounting dimensions
Technical Specification
Type | TWB 40 | |
---|---|---|
Art. no | 307784 | |
Functionality | SAT Wideband LNB | |
RF parameters | ||
SAT input frequency range | GHz | 10,7 12,75 |
IF output frequency range | MHz | 290…2340 |
Gain flatness across full band (p-p) | dB | 7 |
Gain flatness across 26MHz channel (p-p) | dB | 1 |
Noise figure | dB | 0,5 |
LO frequency | GHz | 10,41 |
Image rejection (typ.) | dB | 40 |
XPOL rejection (typ.) | dB | 30 |
Impedance nominal | Ohm | 75 |
Return loss output (min.) | dB | 8 |
General characteristics | ||
Input supply voltage via V port | Vdc | 8…21 |
Current consumption (max.) | mA | 125 |
Output connector V and H | F-female | |
Operating temperature | °C | -30…+60 |
Weight | kg | 0,45 |
Dimensions | mm | 60x60x100 |
Declaration of Conformity
Manufacturer
- TRIAX A/S- Bjoernkaervej 3 – DK-8783 Hornsyld.
Object of Declaration
- TWB 40 Wideband LNB
Reference
- 307784
The object is compliant with the directive(s)
- Radio Equipment Directive 2014/35/EU
- RoHS-Directive 2011/65/EU +2015/863/EU
by meeting the following harmonized standard(s)
- EN 62368-1:2014+/AC:2015 (Safety)
- EN 60728-11:2017+/A11:2018 (Safety)
- EN 55032 :2015+/A11:2020 (EMC)
- EN 55035 :2007 +/A11 :2017 (EMC)
- EN 303 372-2v1.1.1 (RED Article 3b: Selectivity)
- EN 63000:2018 (RoHS)
This Declaration of Conformity is issued by TRIAX A/S
- 15-10-2021
For further information and updated manuals go to. triax.com/support.
Copyright © 2021 TRIAX. All rights reserved. The TRIAX Logo and TRIAX, TRIAX Multimedia are registered trademarks or trademarks of the TRIAX Company or its affiliates.
All specifications in this guide are subject to change without further notice.
TRIAX A/S | Bjørnkærvej 3 | DK-8783 Hornsyld | Denmark.
Read User Manual Online (PDF format)