FUJITSU FOP15182JAZNA1 iM Heat Pumps Instruction Manual
- June 13, 2024
- FUJITSU
Table of Contents
- Features and Benefits
- Heat Pumps
- Designates Metric Conversions
- General Data
- Electrical Data
- Accessories
- Weighted Sound Power Level (dBA)
- Unit Dimensions
- CLEARANCES
- Refrigerant Line Size Information
- GENERAL TERMS OF LIMITED WARRANTY*
- CUSTOMERS SUPPORT
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
FUJITSU FOP15182JAZNA1 iM Heat Pumps
Features and Benefits
- Two-Stage Scroll Compressor: Features two speeds (high and low) of cooling and heating, providing more precise temperature control, lower humidity and greater efficiency when compared to single stage compressors
- 7 mm Condenser Copper Coil1: Requires less refrigerant allowing for a smaller and lighter footprint while enhancing reliability
- Inverted Reversing Valve: Allows for faster heat transfer with gravity assist shifting and reduced joint stress for increased reliability
- Expanded Valve Space: 3 in. – 4 in. – 5 in. service valve space — provides a minimum working area of 27-square inches for easier access
- Triple Service Access: 15″ wide, industry leading corner service access, two fastener, removeable corner and individual louver panels — makes repairs easier and faster
Heat Pumps
F| o| p| 15| 18| 2| j| a| z| n| a|
1
---|---|---|---|---|---|---|---|---|---|---|---
Brand
| Product Category| Type| SEER2| Capacity BTU/HR| Type| Voltage| Region| Refrigerant| Controls| Major Series|
Minor Series
F – Fujitsu
| O – Outdoor Unit| P – Heat Pump| 15 – 15.2 SEER2| 18 – 18,000 [5.28 kW] 24 – 24,000 [7.03 kW] 30 – 30,000 [8.79 kW] 36 – 36,000 [10.55 kW] 42 – 42,000 [12.31 kW] 48 – 48,000 [14.07 kW] 60 – 60,000 [17.58 kW]| ] 2 – 2+ Stage| J – 1 ph 208-230/60| A – All| Z – R-410A| N – Non Comm.| A – 1st Design|
1 – 1st Series
Designates Metric Conversions
AVAILABLE MODELS
| DESCRIPTION
---|---
FOP15182JAZNA1|
1 1/2 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
FOP15242JAZNA1
| 2 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
FOP15302JAZNA1
|
2 1/2 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60
FOP15362JAZNA1|
3 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
FOP15422JAZNA1
| 3 1/2 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
FOP15482JAZNA1
|
4 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
FOP15602JAZNA1|
5 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
STANDARD EQUIPMENT
R-410A Refrigerant
Scroll Compressor
Field Installed Filter Drier
Front Seating Service Valves
Internal Pressure Relief Valve
Internal Thermal Overload
Long Line capability
Low Ambient capability with Kit
3-4-5 Expanded Valve Space
Composite Basepan
2 Screw Control Box Access
15″ Access to Internal Components
Quick release louver panel design
No fasteners to remove along bottom
Optimized Venturi Airflow
Single row condenser coil
Powder coated paint
Rust resistant screws
QR code
External gauge ports
Service trays
General Data
MODEL NO.| FOP1518| FOP1524| FOP1530| FOP1536|
FOP1542| FOP1548| FOP1560
---|---|---|---|---|---|---|---
Nominal Tonnage| | | | | | |
Valve Connections|
Liquid Line O.D. – in.| 0.375| 0.375| 0.375| 0.375| 0.375| 0.375| 0.375
Suction Line O.D. – in.| 0.75| 0.75| 0.75| 0.75| 0.875| 0.875| 0.875
Refrigerant (R410A) furnished oz.¹| 118| 118| 120| 127| 143| 146| 220
Compressor Type| 2-stage Scroll
Outdoor Coil|
Net face area – Outer Coil| 10.9| 10.9| 19.5| 21.5| 21.5| 21.5| 32.5
Net face area – Inner Coil| 10.5| 10.5| | | | |
Tube diameter – in.| 0.276| 0.276| 0.276| 0.276| 0.276| 0.276| 0.375
Number of rows| 2| 2| 1| 1| 1| 1| 1
Fins per inch| 22| 22| 22| 22| 22| 22| 20
Outdoor Fan|
Diameter – in.| 20| 20| 24| 24| 24| 24| 26
Number of blades| 2| 2| 3| 3| 3| 3| 3
Motor hp| 1/6| 1/6| 1/5| 1/5| 1/5| 1/5| 1/5
CFM| 2582| 2582| 4077| 4206| 4206| 4206| 5106
RPM| 1075| 1075| 850| 850| 850| 850| 850
watts| 145| 145| 222| 246| 246| 246| 294
Shipping weight – lbs.| 157| 157| 209| 221| 247| 247| 298
Operating weight – lbs.| 150| 150| 202| 214| 240| 240| 291
Electrical Data
Line Voltage Data (Volts-Phase-Hz)| 208/230-1-60| 208/230-1-60|
208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60|
208/230-1-60
---|---|---|---|---|---|---|---
Maximum overcurrent protection (amps)²| 15| 25| 30| 30| 45| 45| 50
Minimum circuit ampacity³| 11| 15| 18| 20| 26| 28| 31
Compressor|
Rated load amps| 8| 11| 14| 15| 20| 21| 24
Locked rotor amps| 56| 61| 87| 102| 151| 0| 151
Condenser Fan Motor|
Full load amps| 0.75| 0.75| 1.0| 1.0| 1.0| 1.0| 1.0
Locked rotor amps| 1.5| 1.5| 2.56| 2.56| 2.56| 2.56| 2.56
- Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
- HACR type circuit breaker of fuse.
- Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
Accessories
MODEL NO.| FOP1518| FOP1524| FOP1530| FOP1536|
FOP1542| FOP1548| FOP1560
---|---|---|---|---|---|---|---
Compressor crankcase heater*| 44-17402-44| 44-17402-44| 44-17402-44|
44-17402-44| 44-17402-45| 44-17402-45| Factory Standard
Low ambient control| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08|
RXAD-A08| RXAD-A08
Compressor sound cover| 68-23427-26| 68-23427-26| 68-23427-26| 68-23427-26|
68-23427-25| 68-23427-25| 68-23427-25
Compressor hard start kit| SK-A1| SK-A1| SK-A1| SK-A1| SK-A1| SK-A1| SK-A1
Low pressure control| Factory Standard| Factory Standard| Factory Standard|
Factory Standard| Factory Standard| Factory Standard| Factory Standard
High pressure control| Factory Standard| Factory Standard| Factory Standard|
Factory Standard| Factory Standard| Factory Standard| Factory Standard
Liquid Line Solenoid (24 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC|
200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD3T3TVLC|
200RD3T3TVLC
Solenoid Coil| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V|
61-AMG24V| 61-AMG24V
Liquid Line Solenoid (120/240 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC|
200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD3T3TVLC|
200RD3T3TVLC
Solenoid Coil| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V|
61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V
Classic Top Cap w/Label| 91-101123-21| 91-101123-21| 91-101123-21|
91-101123-21| 91-101123-21| 91-101123-21| 91-101123-21
*Bi-flow kits are required when installing a liquid line solenoid on a heat pump.
Weighted Sound Power Level (dBA)
UNIT SIZE – VOLTAGE, SERIES| STANDARD RATING (DBA)| TYPICAL
OCTAVE BAND SPECTRUM (dBA without tone adjustment)
---|---|---
125| 250| 500| 1000| 2000| 4000| 8000
FOP15AZ18A| 73| 58.0| 58.8| 62.0| 62.3| 59.2| 56.6| 50.5
FOP15AZ24A| 73| 56.6| 59.6| 62.2| 62.1| 58.8| 55.4| 50.8
FOP15AZ30A| 72| 48.9| 55.3| 63.6| 61.0| 59.1| 56.5| 48.7
FOP15AZ36A| 74| 51.2| 56.4| 63.1| 63.8| 60.8| 57.4| 56.5
FOP15AZ42A| 74| 56.8| 58.7| 65.9| 66.2| 62.9| 59.4| 54.2
FOP15AZ48A| 74| 57.3| 56.6| 64.1| 64.0| 61.1| 58.0| 56.5
FOP15AZ60A| 74| 43.9| 55.2| 63.4| 65.8| 61.7| 57.9| 52.9
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)
Unit Dimensions
MODEL NO. | OPERATING | SHIPPING |
---|---|---|
H (Height) | L (Length) | W (Width) |
(Length)** | W (Width) | |
INCHES | mm | INCHES |
mm | INCHES | mm |
FOP1518 | 25.00 | 635.00 |
844.55 | 33.25 | 844.55 |
FOP1524 | 25.00 | 635.00 |
844.55 | 33.25 | 844.55 |
FOP1530 | 35.00 | 889.00 |
956.06 | 37.64 | 956.06 |
FOP1536 | 39.00 | 990.60 |
956.06 | 37.64 | 956.06 |
FOP1542 | 39.00 | 990.60 |
956.06 | 37.64 | 956.06 |
FOP1548 | 39.00 | 990.60 |
956.06 | 37.64 | 956.06 |
FOP1560 | 51.00 | 1295.40 |
1000.00 | 39.37 | 1000.00 |
CLEARANCES
NOTE: NUMBERS IN () = mm
IMPORTANT: When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate ventilation to prevent re circulation of discharge air.
Refrigerant Line Size Information
SINGLE AND TWO-STAGE HEAT PUMPS
UNIT SIZE| MAX. LIQUID LINE SIZE| SUCTION LINE SIZE|
OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH IN FEET
0-15| 16-25| 26-50| 51-80| 81-100| 101-125|
126-150
MAXIMUM VERTICAL SEPARATION/CAPACITY MULTIPLIER
1.5 TON| 3/8″| 1/2″| 15 / 1| 25 / 1| 50 / 0.99| 80 / 0.97| 100 / 0.97| 115 /
0.96| 115 / 0.95
5/8″| 15 / 1| 25 / 1| 50 / 1| 80 / 0.99| 100 / 0.99| 115 / 0.99| 115 / 0.98
3/4″| 15 / 1| 25 / 1| 50 / 1| 80 / 0.99| 100 / 0.99| 115 / 0.99| 115 / 0.98
2 TON| 3/8″| 5/8″| 15 / 1| 25 / 1| 50 / 0.99| 80 / 0.98| 100 / 0.97| 100 /
0.96| 95 / 0.95
3/4″| 15 / 1| 25 / 1| 50 / 1| 80 / 0.99| 100 / 0.99| 100 / 0.99| 95 / 0.98
2.5 TON| 3/8″| 5/8″| 15 / 1| 25 / 0.99| 50 / 0.98| 80 / 0.97| 95 / 0.96| 90 /
0.94| 85 / 0.93
3/4″| 15 / 1| 25 / 1| 50 / 0.99| 80 / 0.99| 95 / 0.98| 90 / 0.98| 85 / 0.97
3 TON| 3/8″| 5/8″| 15 / 1| 25 / 0.99| 50 / 0.97| 80 / 0.95| 85 / 0.94| 80 /
0.92| 75 / 0.9
3/4″| 15 / 1| 25 / 1| 50 / 0.99| 80 / 0.98| 85 / 0.98| 80 / 0.97| 75 / 0.96
7/8″| 15 / 1| 25 / 1| 50 / 1| 80 / 0.99| 85 / 0.99| 80 / 0.99| 75 / 0.98
3.5 TON| 3/8″| 3/4″| 15 / 1| 25 / 0.99| 50 / 0.98| 80 / 0.97| 80 / 0.97| 70 /
0.96| 65 / 0.95
7/8″| 15 / 1| 25 / 1| 50 / 0.99| 80 / 0.99| 80 / 0.99| 70 / 0.98| 65 / 0.98
4 TON| 3/8″| 3/4″| 15 / 1| 25 / 0.99| 50 / 0.98| 75 / 0.97| 70 / 0.96| 60 /
0.95| 50 / 0.94
7/8″| 15 / 1| 25 / 1| 50 / 0.99| 75 / 0.99| 70 / 0.98| 60 / 0.98| 50 / 0.97
5 TON| 3/8″| 3/4″| 15 / 1| 25 / 0.99| 50 / 0.97| 65 / 0.95| 45 / 0.94| 30 /
0.92| 15 / 0.9
7/8″| 15 / 1| 25 / 0.99| 50 / 0.99| 65 / 0.98| 45 / 0.97| 30 / 0.96| 15 / 0.96
NOTES:
- Maximum Equivalent Line Length may not exceed 250′.
- Maximum Actual Line Length may not exceed 200′.
Light Grey shaded areas are considered long line and may require accessories as recommended in Long Line Set Guide.
- Refer to supplemental Long Line Set Guide for applications that require liquid line size other than 3/8″.
- DO NOT use suction line traps in the suction riser as this adds additional unwanted pressure drop in the system.
SINGLE AND TWO-STAGE HEAT PUMPS
UNIT SIZE| MAX. LIQUID LINE SIZE| SUCTION LINE SIZE|
OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH IN METERS
0-5| 5.5-8| 8.5-15| 15.5-24| 24.5-30| 30.5-38|
38.5-46
MAXIMUM VERTICAL SEPARATION/CAPACITY MULTIPLIER
1.5 TON| 3/8″| 1/2″| 5 / 1| 8 / 1| 15 / 0.99| 24 / 0.97| 30 / 0.97| 35 / 0.96|
35 / 0.95
5/8″| 5 / 1| 8 / 1| 15 / 1| 24 / 0.99| 30 / 0.99| 35 / 0.99| 35 / 0.98
3/4″| 5 / 1| 8 / 1| 15 / 1| 24 / 0.99| 30 / 0.99| 35 / 0.99| 35 / 0.98
2 TON| 3/8″| 5/8″| 5 / 1| 8 / 1| 15 / 0.99| 24 / 0.98| 30 / 0.97| 30 / 0.96|
29 / 0.95
3/4″| 5 / 1| 8 / 1| 15 / 1| 24 / 0.99| 30 / 0.99| 30 / 0.99| 29 / 0.98
2.5 TON| 3/8″| 5/8″| 5 / 1| 8 / 0.99| 15 / 0.98| 24 / 0.97| 29 / 0.96| 27 /
0.94| 26 / 0.93
3/4″| 5 / 1| 8 / 1| 15 / 0.99| 24 / 0.99| 29 / 0.98| 27 / 0.98| 26 / 0.97
3 TON| 3/8″| 5/8″| 5 / 1| 8 / 0.99| 15 / 0.97| 24 / 0.95| 26 / 0.94| 24 /
0.92| 23 / 0.9
3/4″| 5 / 1| 8 / 1| 15 / 0.99| 24 / 0.98| 26 / 0.98| 24 / 0.97| 23 / 0.96
7/8″| 5 / 1| 8 / 1| 15 / 1| 24 / 0.99| 26 / 0.99| 24 / 0.99| 23 / 0.98
3.5 TON| 3/8″| 3/4″| 5 / 1| 8 / 0.99| 15 / 0.98| 24 / 0.97| 24 / 0.97| 21 /
0.96| 20 / 0.95
7/8″| 5 / 1| 8 / 1| 15 / 0.99| 24 / 0.99| 24 / 0.99| 21 / 0.98| 20 / 0.98
4 TON| 3/8″| 3/4″| 5 / 1| 8 / 0.99| 15 / 0.98| 23 / 0.97| 21 / 0.96| 18 /
0.95| 15 / 0.94
7/8″| 5 / 1| 8 / 1| 15 / 0.99| 23 / 0.99| 21 / 0.98| 18 / 0.98| 15 / 0.97
5 TON| 3/8″| 3/4″| 5 / 1| 8 / 0.99| 15 / 0.97| 20 / 0.95| 14 / 0.94| 9 / 0.92|
5 / 0.9
7/8″| 5 / 1| 8 / 0.99| 15 / 0.99| 20 / 0.98| 14 / 0.97| 9 / 0.96| 5 / 0.96
NOTES:
- Maximum Equivalent Line Length may not exceed 76 Meters.
- Maximum Actual Line Length may not exceed 61 Meters.
- Light Grey shaded areas are considered long line and may require accessories as recommended in Long Line Set Guide.
- Refer to supplemental Long Line Set Guide for applications that require liquid line size other than 3/8″.
- DO NOT use suction line traps in the suction riser as this adds additional unwanted pressure drop in the system.
NOTE: This data includes DTC (Designated Test Combination) ratings and is for reference purposes only. A full listing of official ratings and system match-ups, along with downloadable certificates, will be accessible from the AHRI website: www.ahridirectory.org later this year.
[ ] Designates Metric Conversions
GENERAL TERMS OF LIMITED WARRANTY*
Fujitsu General America, Inc. will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
*For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
Conditional Parts
(Registration Required) ……………………………Ten (10) Years
Before proceeding with installation, refer to installation instructions
packaged with each model, as well as complying with all Federal, State,
Provincial, and Local codes, regulations, and practices.
“In keeping with its policy of continuous progress and product improvement,
Fujitsu reserves the right to make changes without notice.”
CUSTOMERS SUPPORT
*Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps
must be matched with appropriate coil components to meet Energy Star. Ask your
Contractor for details or visit
www.energystar.gov.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>