TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module User Guide

June 3, 2024
TRIAX

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig1

Introduction

Disposal

  • Within in the European Union this label indicates that the product cannot be disposed of with the general household waste. Neither the headend nor the input and output modules can be disposed of with the general household waste.
  • For proper treatment and recycling of old products, please take them to designated collection points in accordance with your na-tional legislation.

Box content

  • A new output module is wrapped in antistatic bubble wrap and packed in a cardboard box when you receive it.
  • Included in the box is a user guide instructing you in how to use the TDX Service Tool to configure the module.

CI module

  • The CI module is one of the modules that you can install in the output sec-tion of your TDX headend unit.
  • You can use the CI module to descramble services that are scrambled or scramble services that you want to scramble using the PanAccess scram-bling system.
  • Below you can see an illustrated description of a CI module with two CI slots.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig2

Basics

Labels

  • A label is placed on the module where you can write the information regard-ing the configuration of the module.
  • Besides the information that you write on the label, the module type and part number are also displayed on the label.

Note

  • The coloured part of the label informs you of the module type. Each type of module is allocated a unique coloured label.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig3

  • On the bottom of the module you will find a label with the bar code and a se-rial number printed on it.

Module installation
You install a CI module by sliding the module into a module slot in the lower section of the headend unit and click it into place.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig4

Note
You can use hot swapping when you insert a module into or re-move a module from the TDX system.

Module removal

  • You release an output module from a slot by using the lock mechanism that is placed to the right of the modules in the output section.
  • Move the lock mechanism slightly to release the module.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig5

CAM/Smart card

  • You can insert 2 Conditional Access modules (CA) into each CI module.
  • Each CA module is able to descramble at least one or more services. Which services depend on the service provider of the CA module and smart card.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig6

Status LED
There is a status LED on the front of each module. The LED indicates wheth-er the module functions according to its purpose or fails.

  • Green – flashing: RedThe CI module receives data.
  • Green – constant on: The CI module receives valid services.
  • Red: When starting the TDX system the CI module and the system controller negotiate connection speed. If the LED continues to be red either the CI module or the system controller has not been inserted correctly.
  • No colour: The CI module has not been configured yet or the module has not been inserted correctly

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig7

When you update the software of a module the status LED provides you with information about the updating process.

  • Orange: Boot loader state.
  • Temporary off: Initiation of the software update.
  • Temporary green: Every time the modules receives a valid data package. Repeated until the update is completed without errors.
  • Red: Software update failed.

TDX Service Tool

Log in

  • When you have loaded the TDX Service Tool from the TDX headend system to your laptop/computer the Login window of TDX Service Tool is displayed.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig8

  • When you have pressed the Log in button the System window is displayed.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig9

CA Modules window

  • Click the CA Modules tab in the TDX Service Tool to display the CA Modules window.
    The first time you display the CA Modules window in a new configuration the module list only displays the number and type of the

  • CA modules that you have inserted in the main and subunits.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig10

  • You have to configure the CA modules individually.
  • To display the Configuration window, click the Setup button of the CA mod-ule you want to configure.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig11

CA Modules configuration window

  • The first time the TDX Service Tool displays the Configuration window for a CA module in a new configuration the fields and radio buttons display default values and nothing is selected in the service list area.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig12

  • Card speed
    • If your smart card is able to use a higher card speed than the default card speed, open the drop-down list with the card speeds you can choose from.
    • Select the card speed you want to use.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig13

  • Card function
    • You can use the Card function radio buttons to determine whether you want the CA module to descramble services that are scrambled or you want the module to scramble services that are not scrambled .
    • Click the Descramble (default) button if you want to de-scramble services .
    • Click the Scramble (PanAccess) button if you want to scramble services using the PanAccess Scrambler.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig14

  * In the Service list area you can select the service or services that you want to descramble and you can set up individual filter options for each service.
  * The services that are scrambled are marked with a dollar sign – $.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig15

  * To select a service, click the check box (square) to the right of the service in question.
  * If you want to change the filter options for a service, click the Setup button of the service in question to open the Filter options window.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig16

  * The first time you open the Filter options window the default value Descram-ble all audio PIDs has been selected.

  * If you want to descramble PIDs (Packet Identifier) that are not audio or video PIDs, click the Descramble non audio/video PIDs check box.

  * In case you do not want to descramble all audio PIDs you can select which audio PIDs you want to descramble.
  * To descramble only selected audio PIDs you have to deselect the Descram-ble all audio PIDs check box.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig19

  * When you have deselected the Descramble all audio PIDs check box a field with a drop-down list is displayed below the check box.
  * To select which audio PID you want to descramble, open the drop-down list with the languages you can choose from.
  * Select the language of the audio PID you want to descramble.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig20

  * When you have selected the required language, a second field is displayed below the first field so you can descramble another audio PID. You can de-scramble as many audio PIDs as you need.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig21

  * If the language of the audio PID you want to descramble is not displayed in the list you can enter a three letter string signifying the language you need.
  * To remove your selection leave the field empty.
  * Click OK to return to the Configuration window.
  * When you have selected the services you want to descramble and changed the filter options you want to change, you have to click the Submit button to save this information in the headend system and return to the CA Modules window.
  * You use the Common interface button to open the common interface menu.
  * Clicking the Common interface button gives you access to information from the smart card inserted in the CA module. The type of information provided by the smart card depends on the card itself and its make.
  * Below is an example of the interface of a Conax card.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig22

  * Please refer to the user guides of the CA modules and smart cards you have inserted in the output modules for further information.
  * If you need to reboot the CA module you can use the Reset CAM button. Click the Reset CAM button to reboot the TDX headend system.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig23

  * When you have selected the services you want to descramble or scramble you have to click the Submit button to enter this information into the head-end system and return to the CA Modules window.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig24

  * When you return to the CA Modules window the descrambled services will be displayed next to the CA module you have configured.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig25

  * Remember to click the Apply button in the upper right-hand corner to save new settings in the configuration.

Status information
To be implemented later.

Save configuration
An important button when you change your configuration of the headend  system is the Apply button placed in the upper right-hand corner of the TDX Service Tool window.

TRIAX 492070 TDX Backend 2CI 2 x CI Backend Module-
fig26

  • Apply
    • Whenever you have made changes in your configuration, “Apply” on the Apply button turns red to tell you that you have unsaved changes that need to be saved.
    • Click the Apply button to save the changes. When chang-es have been saved the “Apply” text looses the red colour.
      WARNING -All unsaved changes will be lost in case of a power cut

ABOUT COMPANY

  • Copyright © 2016 TRIAX. All rights reserved. The TRIAX Logo and TRIAX, TRIAX Multimedia are registered trademarks or trademarks of the TRIAX Company or its affiliates.
  • All specifications in this guide are subject to change without further notice.
  • TRIAX A/S
  • Bjørnkærvej 3
  • DK-8783 Hornsyld
  • Denmark

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals