TRIAX TDC5 dSCR or Legacy and Terr Optical Receiver Instruction Manual

June 13, 2024
TRIAX

TRIAX TDC5 dSCR or Legacy and Terr Optical Receiver

TRIAX-TDC5-dSCR-or-Legacy-and-Terr-Optical-Receiver-
PRODUCT

Product Information:

Product Name TDC5 dSCR/Legacy +Terr Optical Receiver
Part Number 307794
Manufacturer TRIAX UK
Address Treorchy, RCT, CF42 6DL, UK

Product Usage Instructions

Attention!

The installation and commissioning of the TDC5 dSCR/Legacy +Terr Optical Receiver should only be performed by suitably qualified persons, technicians, or installers who comply with safety regulations in EN 62368-1, EN 60825-1 (laser class 1), and EN 60728-11. Failure to comply with the specified precautionary measures may cause serious injury to persons or damage to property. Improper installation, commissioning, or handling may void the warranty.

Disconnect mains power before working on electrical systems.

Installation and Service:

  • A suitably qualified person should always install any additional electrical wiring requirements.
  • Installation or service work should NEVER be undertaken during electrical/thunderstorms.

Waste Electrical and Electronic Equipment (WEEE) Disposal:

Do not dispose of the TDC5 dSCR/Legacy +Terr Optical Receiver in household waste. Dispose of it for recovery and recycling following the current National and European legislation and regulations.

Potential Equalization:

The unit needs to be connected to the MET (Main Earthing Terminal) of the building. The grounding cable should be fixed to the grounding clamp of the metal housing.

Declaration of Conformity:

The manufacturer TRIAX UK declares that the TDC5 dSCR/Legacy +Terr Optical Receiver (Part No. 307794) is compliant with the directives RED 2014/53/EU and RoHS 2011/65/EU. It meets the following harmonized standards: EN 623368-1:2014 +/AC:2015, EN 60825-1:2014, EN 50083-2:2012 +/A1:2015, EN 303 372-2 V1.1.1, EN 61000-3-2:2014, EN 61000-3-3:2013, EN 63000:2018. The declaration is valid until September 4, 2023.

Product Specifications:

Optical inputs 5 optical wavelengths (1310 – 1330 – 1350 – 1370 – 1550nm)
RF outputs 2 x dSCR/legacy + TERR
Frequency range 40 – 694 / 950 – 2150 MHz
Optical input level -10 to +2 dBm
Signal indicator Green LED per wavelength
dCSS/dSCR UBs Output level 4 x 16 85 dB
dSCR (AGC) Output level (Legacy) 78 dB
TERR (AGC) Output level 70 dB
Return loss -8 dB (Typ -12 dB)
Input connector type SC / APC
Output connector type 75 ohm F type (female)*
Band and polarity selection DiSEqC 1.0 (unidirectional), DiSEqC 2.0

(bidirectional)
Standard| EN50494/EN50607, SKY UK protocol
Universal LNB Voltage & Tone| 12 – 20 VDC
Power consumption| 11 W
Power supply| via DC IN (12 – 20 VDC), via output (STB) (12 – 20 VDC)
Power indicator| Green LED
Operating temperature range| -10 to +55 °C
Dimensions| 166 x 170 x 50 mm
Weight| 0.430 kg

Unused ports need to be terminated with a 75 Ohm DC-blocked terminator.

If you have any further questions or need assistance, please contact TRIAX UK at the address provided.

Attention!

The installation and commissioning may only be performed by suitably qualified persons, technicians or installers in compliance with safety regulations in EN 62368-1, EN 60825-1 (laser class 1) and EN 60728-11. Attention should also be paid to the instructions and advice you find below.
Failure to comply with the specified precautionary measures may cause serious injury to persons or damage to property. Damage due to improper installation and commissioning, defective connectors on cables or any other incorrect handling will void the warranty.

Disconnect mains power before working on electrical systems.
A suitably qualified person should always install any additional electrical wiring requirements.
Installation or service work should NEVER be undertaken during electrical / thunderstorms.
Waste Electrical and Electronic Equipment (WEEE) after end of life Do not dispose of these products in household waste! Dispose of them for recovery and recycling following the current National and European legislation and regulations.

Specific safety instructions

  • The transmitter unit needs to be installed in a dry room or cabinet with sufficient air convection.
  • Never connect the PSU to the mains before all cables have been connected to the transmitter.
  • Never look in to an open core of a fibre cable or fibre connector that is in operation with a laser transmitter.
  • Unfiltered Terrestrial antennas must not be connected directly to the TERR port.
  • Un-used F-ports shall be terminated with DC blocked 75 Ohm terminators – like TRIAX DC Blocked Terminator (Art. No. 305349).
  • For potential equalization unit needs to be connected to the MET of the building.
  • The grounding cable shall be fixed to the grounding clamp of the metal housing.

Declaration of Conformity
The manufacturer: TRIAX UK | Treorchy | RCT | CF42 6DL | UK declares that the products: 307794 TDC5 are compliant to the directives: RED 2014/53/EU and RoHS 2011/65/EU by meeting the following harmonized standards:

  • EN 623368-1:2014 +/AC:2015
  • EN 60825-1:2014
  • EN 50083-2:2012 +/A1:2015
  • EN 303 372-2 V1.1.1
  • EN 61000-3-2:2014, EN 61000-3-3:2013
  • EN 63000:2018

Product introduction and specs

The TDC5 is an Optical Fibre Receiver, from the TRIAX Optical Fibre range.
Unique dSCR/legacy TWIN Optical Convertor with high output power, developed to help installers overcome low signal quality in satellite fibre installations.

  • TDC5: 5 optical wavelengths are converted to 2 x dSCR/legacy + separate TERR
  • Unique product in the market with high output power
  • Optical input level: -10 to +2 dBm
  • 5 Optical wavelengths: 1310 – 1330 – 1350 – 1370 – 1550m
  • AGC on all output ports
  • Signal quality indicator per wavelength
  • Sky compatible
  • Energy efficient
  • Can be used in systems with up to 32 splits
  • Power supply: Part No. 318165
    TDC5 (Part No. 307794)
Optical inputs 1
RF outputs 2 x dSCR/legacy + TERR.
Optical wavelengths nm 1310 – 1330 – 1350 – 1370 – 1550
Frequency range MHz 40 – 694 / 950 – 2150
Optical input level dBm -10 to +2
Signal indicator Green LED per wavelength
dCSS/dSCR UBs 4 x 16
Output level dSCR (AGC) dBµV 85
Output level Legacy (AGC) dBµV 78
Output level TERR (AGC) dBµV 70
Return loss dB -8 (Typ -12)
Input connector type SC / APC
Output connector type 75 ohm F type (female)*
Band and polarity selection DiSEqC 1.0 (unidirectional) DiSEqC 2.0

(bidirectional)

Standard EN50494/EN50607 SKY UK protocol

Universal LNB Voltage & Tone

Power consumption| W| 11
Power supply via DC IN| VDC| 12 – 20
Power supply via output (STB)| VDC| 12 – 20
Power indicator| –| Green LED
Operating temperature range| °C| -10 to +55
Dimensions| mm| 166 x 170 x 50
Weight| kg| 0.430

Unused ports need to be terminated with 75 Ohm DC-blocked terminator

Product installation

Dual SAT & TERR distribution over a single Fibre Optic Network (up to 32 Splits)

TRIAX-TDC5-dSCR-or-Legacy-and-Terr-Optical-Receiver-1

4 x SAT & TERR distribution over Fibre Optic Network (up to 32 Splits)

TRIAX-TDC5-dSCR-or-Legacy-and-Terr-Optical-Receiver-2

Information and manuals:

Subject to change without notice
Copyright © 2023 TRIAX. All rights reserved.
The TRIAX Logo and TRIAX Multimedia are registred trademark(s) of the TRIAX UK or its affiliates.

triax.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals