GENERAL CHARACTERISTICS

WE RECOMMEND THAT ALL PLUMBING PRODUCTS BE INSTALLED BY A LICENSED PROFESSIONAL IMPORTANT: Thoroughly read instructions before installation.

WARNING: IF THIS VALVE IS INSTALLED UPSIDE-DOWN A REVERSE CARTRIDGE IS NOT AVAILABLE. CONSEQUENTLY, VALVE MUST BE REMOVED AND REINSTALLED RIGHT-SIDE UP.

  • The valve is designed with two outlets for ease of installation, but are not intended to be used concurrently with each other. Using both outlets will reduce the performance of the valve.

VALVE SPECIFICATION

  • Recommended supply pressure = 20 to 80 psi (1,38-5,52 bar)
  • Recommended hot water supply temperature = 120° to 140°F (48°-60°C)
  • Operating pressures between hot and cold supplies should vary no more than 30 psi (2,07 bar). If water pressure exceeds 70 psi (4,83 bar), install a pressure-reducing valve.
  • Ensure the mixing valve is in compliance with local plumbing codes when setting the temperature on the water heater.
  • It is the installer’s responsibility to verify correct temperature setting to prevent any risk of scalding prior to consumer use.
  • For use with shower heads rated at 1.8 gpm (6.8 L/min) or higher PHYLRICH-PHY1137-3-4-Medi-Thermostatic-Valve-2
  • Female 3/4” NPT inlets and outlets
  • Factory temperature setting = 100°F (38°C)
  • Temperature range = 52° to 118°F (11°-48°C)
  • Temperature hot supply = 149° to 180°F (65°-82°C)
  • Temperature cold supply = 50° to 72°F (10°-22°C)
  • Temperature stability = Compliant with ASSE 1016

PARTS BREAKDOWN

  • Medi Thermostatic Valve
  • TURN TO PAGE 8 FOR VALVE TURN MECHANICSPHYLRICH-PHY1137-3-4-Medi-Thermostatic-Valve-3
    1-135 3/4” Medi Therm Valve|
    ---|---
    #| PART #| DESCRIPTION| QTY.
    1| 11496| MUD GUARD| 1
    2| 92335| SCREW| 1
    3| 90011| O- RING| 2
    4| 10054| STEM EXTENSION| 1
    5| 10209| SHANK,NIPPLE THREAD ALL| 1
    6| 11610| MEDITHERM NUT FOR ALL THREAD| 1
    7| 11320| SAFETY AND MECHANICAL STOP| 1
    8| 11598| CARTRIDGE LIMIT STOP SLEEVE, MEDI| 1
    9| 11599| RETAINER NUT| 1
    10| 11583| CARTRIDGE| 1
    11| 2- 256| SHUT OFF NUT| 2
    12| 11593| CHECK VALVE| 2
    13| 92050| WASHER ACETAL| 1
  • Medi Thermostatic Valve w/ 3/4” VOLUME CONTROL
  • 3/4” NPT female outlet
    1-136 3/4” Medi Therm Valve w/ Volume Control|
    ---|---
    #| PART #| DESCRIPTION| QTY.| PARTS FROM THERM VALVE
    1| 11496| MUDGUARD| 1
    2| 92335| SCREW| 1
    3| 90011| O- RING| 2
    4| 10054| STEM EXTENSION| 1
    5| 10209| SHANK, NIPPLE THREAD ALL| 1
    6| 11610| MEDITHERM NUT FOR ALL THREAD| 1
    7| 11320| SAFETY AND MECHANICAL STOP| 1
    8| 11598| CARTRIDGE LIMIT STOP SLEEVE, MEDI| 1
    9| 11599| RETAINER NUT| 1
    10| 11583| CARTRIDGE| 1
    11| 2- 256| SHUT OFF NUT| 2
    12| 11593| CHECK VALVE| 2|
    13| 92050| WASHER ACETAL| 1
    14| 11496| MUDGUARD| 1
    15| 92157| SCREW| 1
    16| 90011| O- RING| 2
    17| 11416| STEM EXTENSION| 1
    18| 11498| SHANK, NIPPLE THREAD ALL| 1
    19| 10058| NUT, ADAPTOR CARTRIDGE| 1
    20| 10215| CARTRIDGE VALVE| 1
    21| 2- 259| 3/4” MEDITHERM W/ VOLUME CONTROL| 1
  • Medi Thermostatic Valve w/ 2 VOLUME CONTROL
  • 3/4” NPT female outletsPHYLRICH-PHY1137-3-4-Medi-Thermostatic-Valve-5
    #| PART #| DESCRIPTION| QTY.| PARTS FROM THERM VALVE
    ---|---|---|---|---
    1| 11496| MUD GUARD| 1
    2| 92335| SCREW| 1
    3| 90011| O- RING| 2
    4| 10054| STEM EXTENSION| 1
    5| 10209| SHANK,NIPPLE THREAD ALL| 1
    6| 11610| MEDITHERM NUT FOR ALL THREAD| 1
    7| 11320| SAFETY AND MECHANICAL STOP| 1
    8| 11598| CARTRIDGE LIMIT STOP SLEEVE, MEDI| 1
    9| 11599| RETAINER NUT| 1
    10| 11583| CARTRIDGE| 1
    11| 2- 256| SHUT OFF NUT| 2
    12| 11593| CHECK VALVE| 2|
    13| 92050| WASHER ACETAL| 1
    14| 11496| MUDGUARD| 2
    15| 92157| SCREW| 2
    16| 90011| O- RING| 4
    17| 11416| STEM EXTENSION| 2
    18| 11498| SHANK,NIPPLE THREAD ALL| 2
    19| 10058| NUT, ADAPTOR CARTRIDGE| 2
    20| 10215| CARTRIDGE VALVE| 2
    21| 2- 260| 3/4” MEDITHERM W/ 2 VOLUME CONTROL| 1
  • Medi Thermostatic Valve w/ 3 WAY DIVERTER
  • 1/2” NPT female outletsPHYLRICH-PHY1137-3-4-Medi-Thermostatic-Valve-6
    1-137 3/4” Medi Therm Valve w/ 3 Way Diverter|
    ---|---
    #| PART #| DESCRIPTION| QTY.
    1| 11496| MUD GUARD| 1
    2| 92335| SCREW| 1
    3| 90011| O- RING| 2
    4| 10054| STEM EXTENSION| 1
    5| 10209| SHANK,NIPPLE THREAD ALL| 1
    6| 11610| MEDITHERM NUT FOR ALL THREAD| 1
    7| 11320| SAFETY AND MECHANICAL STOP| 1
    8| 11598| CARTRIDGE LIMIT STOP SLEEVE, MEDI| 1
    9| 11599| RETAINER NUT| 1
    10| 11583| CARTRIDGE| 1
    11| 2- 256| SHUT OFF NUT| 2
    12| 11593| CHECK VALVE| 2
    13| 92050| WASHER ACETAL| 1
    14| 11496| MUD GUARD| 1
    15| 92157| SCREW| 1
    16| 90011| O- RING| 2
    17| 11416| STEM EXTENSION| 1
    18| 11498| SHANK,NIPPLE THREAD ALL| 1
    19| 10349| NUT, 3 WAY DIVERTER| 1
    20| 11297| CARTRIDGE VALVE, 3 WAY| 1
    21| 2- 261| 3/4” MEDITHERM W/ 3 WAY DIVERTER| 1
  • Medi Thermostatic Valve w/ 2 WAY DIVERTER
  • 1/2” NPT female outletsPHYLRICH-PHY1137-3-4-Medi-Thermostatic-Valve-7
    1-142 3/4” Medi Therm Valve w/ 2 Way Diverter|
    ---|---
    #| PART #| DESCRIPTION| QTY.| PARTS FROM THERM VALVE
    1| 11496| MUD GUARD| 1
    2| 92335| SCREW| 1
    3| 90011| O- RING| 2
    4| 10054| STEM EXTENSION| 1
    5| 10209| SHANK,NIPPLE THREAD ALL| 1
    6| 11610| MEDITHERM NUT FOR ALL THREAD| 1
    7| 11320| SAFETY AND MECHANICAL STOP| 1
    8| 11598| CARTRIDGE LIMIT STOP SLEEVE, MEDI| 1
    9| 11599| RETAINER NUT| 1
    10| 11583| CARTRIDGE| 1
    11| 2- 256| SHUT OFF NUT| 2
    12| 11593| CHECK VALVE| 2|
    13| 92050| WASHER ACETAL| 1
    14| 11496| MUD GUARD| 1
    15| 92157| SCREW| 1
    16| 90011| O- RING| 2
    17| 11416| STEM EXTENSION| 1
    18| 11498| SHANK,NIPPLE THREAD ALL| 1
    19| 10349| NUT, 3 WAY DIVERTER| 1
    20| 11567| CARTRIDGE VALVE, 2 WAY| 1
    21| 2- 262| 3/4” MEDITHERM W/ 2 WAY DIVERTER| 1

ROUGH IN DIMENSIONS / ROUGH IN VALVE TO FRAME

(All dimesions shown are to the nearest 1/16”) Once the desired location has been determined, install a cross support beam to wall studs. Ensure to level the valve & secure to the cross support. The valve should be level horizontally, vertically, & parallel to finished wall.

  • 3”x 8” Opening for finished wall for 2 valves 3” x 13” for 3 valvesPHYLRICH-PHY1137-3-4-Medi-Thermostatic-Valve-8

Pre-assemble fittings before attaching to cross support. Attach the “COLD” Inlet to Cold Supply & “HOT” Inlet to Hot Supply using copper supply lines.
IMPORTANT: Thoroughly flush supply lines to remove any debris prior to installation to pevent damage & malfunction of thermostatic cartridge.

  • Use plumber’s tape or thread sealant to all threaded port joints & attach to valve. All soldering/brazing of fittings shall be performed a minimum of 6” away from valve.

WARNING: DO NOT APPLY HEAT DIRECTLY TO THE VALVE AS THIS MAY DAMAGE RUBBER & PLASTIC SEALS & WILL AVOID WARRANTY. TURN ON WATER SUPPLIES TO VALVE & CHECK FOR LEAKS.

MAINTENANCE

THERMOSTATIC CARTRIDGE
Carefully remove the trim and plate and place in a safe location for the time being. Use a flat head screwdriver to shut off the water supply to the cartridge by turning the temporary shutoff screws clockwise until screw stops. Ensure to close both the hot and cold sides of the water supplies. Remove extensions to gain access to the cartridge nut. Unscrew the cartridge nut using a 11/16” socket wrench or adjustable wrench, if possible.
Gently pull the cartridge out of the housing body (rotating cartridge while pulling may assist in removing). Clean the cartridge by rinsing it under running water to remove any possible debris. Wipe cartridge and housing seat clean and apply a thin film of NON-PETROLEUM GREASE to o-rings.
NOTE: Do NOT use oil based lubricants as this may cause the o-rings to dry out over time and crack.

How to calibrate temperature:
To limit the amount of HOT water allowed to mix with cold water, use a 4 “ long flat blade screw driver to remove the stem. Unscrew and remove nut for all thread using a 3/4” socket. Remove the limit safety stop and rotate the stem counterclockwise till the desired maximum temperature is found. The maximum temperature is factory set at 120°F. Once the desired temperature is set, reinstall the safety stop at the maximum position. Proceed installing the stem and trim.PHYLRICH-PHY1137-3-4-Medi-Thermostatic-
Valve-10

Carefully install the cartridge back into the housing body and tighten nut to 10 ft-lbs (13,56 nm).
ATTENTION: Ensure the INDICATOR HOLE on cartridge is orientated at the 6 O’Clock position. The Temp erature stop must be in the 12 O’Clock position.

CHECK VALVES
Shut off water supply at main or upstream from valve body. Remove check valve nut with a 15 mm socket wrench from the body. If check valve needs replacement, forcefully remove check valve w/ needle nose pliers. Wipe check valve and housing seat clean and apply a thin film of NON-PETROLEUM GREASE to o-rings. Install new check valves by pressing them in evenly & ensuring check valve snaps into place.
NOTE: Do NOT use oil based lubricants as this may cause o-rings to dry out over time and crack.
Tighten check valves to 10 ft-lbs (13,56 nm).

Reinstate water supply from upstream and check for leaks.
Check operation of flow. If improved, proceed to reinstall extensions, trim, & plate; otherwise, see PARTS BREAKOUT for any replacement parts needed.