PHYLRICH Shop 1-2 Inch NEW Thermostatic Valve with 3 Way SHARED Diverter Instruction Manual
- June 5, 2024
- PHYLRICH
Table of Contents
Defining Luxury Since 1959
INSTALLATION INSTRUCTIONS FOR
1/2 Mini Thermostatic Valve 1-115
- w/ 3 Way Diverter shared 1-133
- w/ 2 Way Diverter shared 1-134
GENERAL CHARACTERISTICS
WE RECOMMEND THAT ALL PLUMBING PRODUCTS BE INSTALLED BY A LICENSED PROFESSIONAL IMPORTANT: Thoroughly read instructions before installation.
WARNING: IF THIS VALVE IS INSTALLED UPSIDE-DOWN A REVERSE CARTRIDGE IS NOT
AVAILABLE.
CONSEQUENTLY, THE VALVE MUST BE REMOVED AND REINSTALLED RIGHT-SIDE UP.
The valve is designed with two outlets for ease of installation but is not intended to be used simultaneously with each other. Using both outlets will reduce the performance of the valve.
VALVE SPECIFICATION
Recommended supply pressure = 20 to 80 psi (1,38-5,52 bar)
Recommended hot water supply temperature = 120° to 140°F (48°-60°C)
Operating pressures between hot and cold supplies should vary no more than 30
psi (2,07 bar). If water pressure exceeds 70 psi (4,83 bar), install a
pressure-reducing valve.
Ensure the mixing valve is in compliance with local plumbing codes when
setting the temperature on the water heater.
It is the installer’s responsibility to verify the correct temperature setting
to prevent any risk of scalding prior to consumer use.
For use with shower heads rated at 1.3 GPM (4.9 L/min) or higher
Male 1/2” NPT inlets and outlets
Factory temperature setting = 100°F (38°C)
Temperature range = 52° to 118°F (11°-48°C)
Temperature hot supply = 149° to 180°F (65°-82°C)
Temperature cold supply = 50° to 72°F (10°-22°C)
Temperature stability = ±32°F (0°C)
PARTS BREAKDOWN
Mini Thermostatic Valve
- 1-115
1-115 Mini Therm Valve
# | PART # | DESCRIPTION | QTY |
---|---|---|---|
1 | 10054 | STEM EXTENSION | 1 |
2 | 10209 | SHANK, NIPPLE THREAD ALL | 1 |
3 | 10624 | BODY, MINI THERMOSTATIC | 1 |
4 | 11197 | CHECK VALVE | 2 |
5 | 12076 | RETAINER NUT | 1 |
6 | 12073 | COVER SLEEVE ADAPTOR | 1 |
7 | 11973 | CARTRIDGE MINI THERM | 1 |
8 | 2-130 | SHUTOFF NUT | 2 |
9 | 90011 | 0-RING | 2 |
10 | 92335 | SCREW | 1 |
Mini Thermostatic Valve w/ 3 WAY DIVERTER SHARED 1-133
(If you have purchased the Mini Therm Valve
w/ 3 Way Diverter)
1-133 Mini Therm Valve w/ 3 Way Diverter
PARTS FROM THERM VALVE
# | PART # | DESCRIPTION | QTY |
---|---|---|---|
1 | 10054 | STEM EXTENSION | 1 |
2 | 10209 | SHANK, NIPPLE THREAD ALL | 1 |
3 | 10624 | BODY, MINI THERMOSTATIC | 1 |
4 | 11197 | CHECK VALVE | 2 |
5 | 12076 | RETAINER NUT | 1 |
6 | 12073 | COVER SLEEVE ADAPTOR | 1 |
7 | 11973 | CARTRIDGE MINI THERM | 1 |
8 | 2-130 | SHUTOFF NUT | 2 |
9 | 90011 | 0-RING | 2 |
10 | 92335 | SCREW | 1 |
11 | 2-242 | MINI THERMO W/ DIV. | 1 |
12 | 92157 | SCREW | 1 |
13 | 11416 | STEM EXTENSION, XXL | 1 |
14 | 11498 | ALL THREAD, EXTENSION, XXL | 1 |
15 | 10349 | NUT, 3 WAY DIVERTER | 1 |
16 | 11417 | CARTRIDGE, 3 WAY SHARED | 1 |
17 | 90011 | 0-RING | 2 |
Mini Thermostatic Valve w/ 2 WAY DIVERTER SHARED
1-134
(If you have purchased the Mini Therm Valve w/ 2 Way Diverter)
1-134 Mini Therm Valve w/ 2 Way Diverter
PARTS FROM THERM VALVE
# | PART # | DESCRIPTION | QTY |
---|---|---|---|
1 | 10054 | STEM EXTENSION | 1 |
2 | 10209 | SHANK, NIPPLE THREAD ALL | 1 |
3 | 10624 | BODY, MINI THERMOSTATIC | 1 |
4 | 11197 | CHECK VALVE | 2 |
5 | 12076 | RETAINER NUT | 1 |
6 | 12073 | COVER SLEEVE ADAPTOR | 1 |
7 | 11973 | CARTRIDGE MINI THERM | 1 |
8 | 2-130 | SHUTOFF NUT | 2 |
9 | 90011 | 0-RING | 2 |
10 | 92335 | SCREW | 1 |
11 | 2-274 | MINI THERMO W/ DIV. | 1 |
12 | 92157 | SCREW | 1 |
13 | 11416 | STEM EXTENSION, XXL | 1 |
14 | 11498 | ALL THREAD, EXTENSION, XXL | 1 |
15 | 10349 | NUT, 3 WAY DIVERTER | 1 |
16 | 11568 | CARTRIDGE, 3 WAY SHARED | 1 |
17 | 90011 | 0-RING | 2 |
ROUGH-IN DIMENSIONS / ROUGH-IN VALVE TO FRAME
(All dimensions shown are to the nearest 1/16”)
Once the desired location has been determined, install a cross support beam to wall studs. Ensure to level the valve & secure to the cross support. The valve should be level horizontally, vertically, & parallel to the finished wall.
- Opening for Finished wall
Pre-assemble fittings before attaching to cross support. Attach the “COLD” Inlet to Cold Supply & “HOT” Inlet to Hot Supply using copper supply lines.
IMPORTANT: Thoroughly flush supply lines to remove any debris prior to installation to prevent damage & malfunction of the thermostatic cartridge.
- Use plumber’s tape or thread sealant to all threaded port joints & attach it to the valve. All soldering/brazing of fittings shall be performed a minimum of 4” away from the valve.
WARNING:
DO NOT APPLY HEAT DIRECTLY TO THE VALVE AS THIS MAY DAMAGE RUBBER & PLASTIC
SEALS & WILL AVOID WARRANTY. TURN ON WATER SUPPLIES TO VALVE & CHECK FOR LEAKS
MAINTENANCE
THERMOSTATIC CARTRIDGE
Carefully remove the trim and plate, and place in a safe location for the time
being. Use a flat head screwdriver to shut off the water supply to the
cartridge by turning the temporary shutoff screws clockwise until the screw
stops. Ensure to close both the hot and cold sides of the water supplies.
Remove extensions & cover sleeve to gain access to the cartridge nut. Unscrew
the cartridge nut using a 1 1/32” plumbers wrench or adjustable wrench, if
possible. Gently pull the cartridge out of the housing body (rotating the
cartridge while pulling may assist in removing it). Clean the cartridge by
rinsing it under running water to remove any possible debris. Wipe cartridge
and housing seat clean and apply a thin film of NON-PETROLEUM GREASE to
o-rings.
NOTE: Do NOT use oil-based lubricants as this may cause the o-rings to dry out over time and crack.
How to calibrate temperature:
To limit the amount of HOT water allowed to mix with cold water, use a 4 “
long flat blade screwdriver to remove the stem. Unscrew and remove the cover
sleeve using a 3/4” socket.
Remove o-ring and pull off-limit stop and rotate the stem counterclockwise
till the desired maximum temperature is found. The maximum temperature is
factory set at 120°F. Once the desired temperature is set, reinstall the
safety limit and stop at the maximum position (Against Pin). Proceed to
install the stem and trim.
CHECK VALVES
Shut off the water supply at main or upstream from the valve body. Remove
check valve nut with a 5/8” (16mm) socket wrench from the body.
If the check valve needs replacement, forcefully remove the check valve w/
needle-nose pliers.
Wipe check valve and housing seat clean and apply a thin film of NON-PETROLEUM
GREASE to o-rings.
Install new check valves by pressing them in evenly & ensuring the check valve snaps into place.
NOTE: Do NOT use oil-based lubricants as this may cause o-rings to dry out over time and crack.
Tighten check valve nut(s) to 10 ft-lbs (13,56 nm).
Turn on the water supply from upstream and check for leaks.
Check operation of flow. If improved, proceed to reinstall extensions, trim, &
plate; otherwise, see PARTS BREAKOUT for any replacement parts needed.
VALVE TURN MECHANICS
RECOMMEND INSTALLING FUNCTIONALITY AS SHOWN BELOW, 1, 2 & 3 CONSEQUENTIAL.
1-133 THERMOSTATIC VALVE W/ 3 WAY DIVERTER (SHARED)
1-134 THERMOSTATIC VALVE W/ 2 WAY DIVERTER (SHARED)
Defining Luxury Since 1959
1261 Logan Ave., Costa Mesa, CA 92626 P: 714.361.4830 F: 714.617.3120
www.phylrich.com