SAFETY INSTRUCTIONS
This manual contains safety and operating instructions. Please read it carefully before using the device for the first time and keep it for future reference. This machine should only be used for charging or power supply operations specified within the limits indicated on the machine and in the instruction manual. The operator must observe the safety precautions. In case of improper or unsafe use, the manufacturer cannot be held liable. The device is destined to be used indoors. Must not be exposed to the rain. This unit can be used by children aged 8 or over and by people with reduced physical, sensory or mental capabilities or lack of experience or knowledge, if they are properly monitored or if instructions for using the equipment have safely been read and potential risks understood.
Children must not play with the product. Cleaning and maintenance should not be performed by an unsupervised child. Do not use to charge domestic batteries or non rechargeable batteries. Do not use the charger if the mains cable or plug is damaged. Do not use the device if the charging cable appears to be damaged or assembled incorrectly in order to avoid any risk of short circuiting the battery. Never use on a frozen or damaged battery. Do not cover the device. Do not place the unit near a heat source or expose to prolonged high temperatures (above 60°C). Do not obstruct the cooling vents. The operating mode of the automatic charger and the restrictions applicable to its use are explained later in this manual.
Fire and explosion risks!
- A battery can emit explosive gases when on charge.
- During the charge, the battery must be placed in a well ventilated area.
- Avoid flames and sparks.
- Protect the electrical contact surfaces of the battery against short circuits.
- Do not leave a charging battery unattended for a long time.
Risk of acid dispersion!
- Wear protective goggles and gloves.
- In case of contact with the eyes or the skin, rinse immediately with water and see a medical doctor as soon as possible.
Connection / disconnection
- Disconnect the power supply before plugging or unplugging the connections to/from the battery.
- Always ensure the Red clamp is connected to the «+» battery terminal first. If it is necessary to connect the black clamp to the vehicle chassis, make sure it is a safe distance from the battery and the fuel line. The charger must be connected to the mains.
- After charging, disconnect the charger from the mains, then disconnect the negative clamp from the car body and then disconnect the positive clamp from the battery, in this order.
Connection :
- The charger must be connected to an earthed power supply.
- The connection to the power supply must be carried out in compliance with national standards
Maintenance
- If the power supply cable is damaged, the replacement cable must be obtained from the manufacturer or its service team.
- Maintenance should only be carried out by a qualified person.
- Warning ! Always disconnect from the mains before performing maintenance on the device.
- The device does not require any specific maintenance.
- If the internal fuse is melted, it must be replaced by the manufacturer (GYS dedicated sales service) or by an equally qualified person to prevent any accidents.
- Do not use solvents or any agressive cleaning products.
Regulations :
- The Machine is compliant with European directives.
- The declaration of conformity is available on our website.
- EAEC Conformity marking (Eurasian Economic Community).
- Equipment in compliance with British requirements. The British Declaration of Conformity is available on our website (see home page).
- Equipment in conformity with Moroccan standards.
- The declaration C م (CMIM) of conformity is available on our website (see cover page).
Waste management:
This product should be disposed of at an appropriate recycling facility. Do
not throw away in a household bin.
GENERAL DESCRIPTION
Your GYSFLASH is a professional multifunctional charger with Inverter
technology. Designed to support the batteries of demonstra-tion vehicles or
during the diagnostic work, it also guarantees an ideal quality of charge for
the maintenance of the most advanced models. This charger can be fitted with
cables up to 8 m long. Changing the charging cables requires recalibration
(see page 21). It is considered a fixed device not a mobile product.
Your GYSFLASH is supplied with a software that includes 4 different modes to
choose from:
- Charging mode : dedicated to the charging of lead-acid (sealed, liquid, AGM…) or lithium (LiFePO4) starter batteries.
- Power mode | Diag+ : Supplies the energy required during diagnostic work on the vehicle.
- Power mode | Showroom : Maintains the charge of the battery and supplies the energy required when using the consumers of a demonstration vehicle.
- Tester Mode : Used to check the state of the battery and test the vehicle starting system and alternator.
Your GYSFLASH is SMART!
The original features of your GYSFLASH can be extended by adding specific
charging modes and profiles using the USB port and custom settings (see page
23). Your GYSFLASH also offers the possibility to recover data from several
hundred charging operations on your USB stick for analysis on a spreadsheet.
Additional modules (such as printer, Ethernet port, etc.) can also be
connected to the charger via its dedicated module socket.
Auto-Detect» function:
The GYSFLASH is equipped with the «Auto-Detect» function which automatically
starts a charge when a battery is connected to the charger. (To enable/disable
this function see page 21)
Auto-Restart» function:
The «Auto-Restart» function offers the possibility of automatically restarting
the charger in the event of a power failure. (To enable/disable this function
see page 21)
«Lock» function:
It is possible to lock the buttons on your GYSFLASH when it is used in a place
open to the public or unattended. To activate/deactivate the lock, press and
hold and for 3 seconds.
START UP
- Connect the charger to the mains.
- Set the switch, located at the back of the charger, to «ON».
- Select the desired mode (Charge -> Showroom -> Diag+ -> Tester).
To access the «configuration» menu press the key for 3s
CHARGE MODE
Setting the mode:
Press the SELECT button for 3 seconds to activate the
modification of the mode settings.
Use the arrows to change the value of the parameter.
Press the SELECT button to accept the value and move
to the next parameter.
- Type of charge
- Charge profile
- Rated battery voltage
- Rated battery capacity
Charge type:| Profil| Charging voltage|
---|---|---|---
Pb-CHARGE
| normal| 2.40 V/cell| Lead batteries of the types Gel, MF, EFB, SLA…
AGM
| ****
2.45 V/cell
| Most AGM lead-acid batteries including START and STOP.
However, some AGM batteries require a lower voltage charge (Normal profile). Check
the battery manual if in doubt.
water| 2.45 V/cell| Open liquid-type lead-acid batteries with cap.
Easy
| ****
2.40 V/cell
| Profile dedicated to lead batteries that automatically adapts the charging current according to the size of the battery.
However, for maximum charge optimization, it is recommended, when possible, to
use normal, AGM or liquid charge curves.
Li-CHARGE| LFP/LiFePO4| 3.60 V/cell| Lithium batteries type LFP (Lithium Ferro Phosphate)
Start of the charge:
Precautions :
When charging a vehicle, it is recommended to reduce the vehicle power
consumption to a minimum (switch off the lights, switch off the ignition,
close the doors, etc.) in order not to disturb the charging process.
Precaution : Check the electrolyte level of any open battery. Fill it up if necessary, before starting the charge.
Lead-acid charging curve:
- Step 1 : Analysis Analyses the state of the battery (charge level, polarity inver-sion, wrong battery…)
- Step 2 : Recovery Recovering damaged elements after deep and prolonged discharge.
- Step 3 : Test Sulfated battery test
- Step 4 : Desulfation Battery desulfation algorithm.
- Step 5 : Charge Fast charge at maximum current to reach 80% charge level.
- Step 6 : Absorption Constant voltage charge to reach 100% charge level.
- Step 7 : Refresh (only for liquid profile) The charger supplies an additional current to create gas that will allow the electrolyte to be mixed and thus reconditioning the battery cells. During this phase, the battery may produce some water.
- Step 8 : Maintenance/Floating charge Maintains battery charge level at its maximum.
LFP Lithium charging curve:
- Step 1 : Analysis Analyses the state of the battery (charge level, polarity inver-sion, wrong battery…)
- Step 2 : UVP Wake up Reactivates batteries in UVP protection (Under Voltage Protec-tion)
- Step 3 : Recovery Recovery algorithm following a deep discharge.
- Step 4 : Charge Maximum current fast charge to reach an 90% charge level.
- Step 5 : Absorption Constant voltage charge to reach a 95% charge level.
- Step 6 : Test Charge conservation test.
- Step 7 : Supplement Reduce current charge to reach 100% charge level.
- Step 8 : Equalization / Balancing Balancing the battery cells
- Step 9 : Maintenance/Floating charge Maintain the battery charge level at its maximum.
POWER SUPPLY MODES: SHOWROOM / DIAG+
Setting the mode:
Power limitation: If the symbol «» appears next to the current setting (eg «I: 50A »), this indicates that the charger cannot deliver this current at the voltage set on the display. At this voltage level, the charger will be running at maximum power. However, this current could be delivered at lower voltage depending on the power output of the charger.
Start of the charge:
Precautions :
When starting the mode, a current displayed above 10 A means that your battery
is discharged. The device will start charging automatically Check that there
is no electrical consumer on the vehicle. Wait until the current supplied
drops below 10 A before starting any action on the vehicle (use of the
vehicle’s electrical accessories, diagnostic operation, etc.).
Features of the power modes:
«No battery» function (not recommended):
This function allows you to use the SHOWROOM power mode when there is no
battery. To do this, press the START/STOP button for 3 seconds. The «No
battery mode» indication is displayed for 3 seconds before forcing the power
supply. It is strongly recommended not to use the «no battery» function if a
battery is present.
This function disables the «Integrated charging» function, as well as some of
the protections such as abnormal undervoltage protection or disconnection
detection.
In this configuration, reverse polarity can damage the vehicle electronics.
«Integrated charging» function: The SHOWROOM mode (outside of the «no battery»
function) incorporates an automatic charging algorithm adapted to all types of
batteries (lead and lithium), in order to guarantee an optimal charge level
for demonstration vehicles. This function is perfectly compatible with the
presence of consumers on the battery.
- Step 1 : Analysis Analysis of the battery condition (charge level, inversion, etc.) polarity, wrong battery connected, etc).
- Step 2 : Charging Fast charging at maximum current until U1 is reached (ex: 13.8 V to )
- Step 3 : Absorption Charge under constant voltage U1 (ex: 13.8 V in ). Maximum duration 1 hour.
- Step 4 : Complement Gradual increase of the voltage up to U2 (ex: 14.4 V to ). Maximum duration 2 hours
- Step 5 : Equalization / Balancing Maintaining the voltage U2 (ex: 14.4V at ). Maximum duration 2 hours
- Step 6 : Power supply mode Application of the selected voltage
TESTER MODE
General navigation
Voltage test:
This mode allows you to view the voltage at the terminals of the charging
clamps and thus use your GYSFLASH as a voltmeter, in order to measure the
battery voltage
Start-up test:
The purpose of this mode is to evaluate the state of a vehicle starting system
(starter + battery) when the engine is turned on. This test must be done with
the battery connected to the vehicle.
Test result : The charger indicates the minimum value of the battery voltage perceived during the engine start phase, as well as the status of the start system in the form of a gauge.
Alternator test :
This mode is used to determine the condition of the alternator in the vehicle.
This test is performed on a vehicle with the engine
running.
PROTECTIONS
This device is protected against short circuits and polarity reversals. It has an anti-spark system that prevents sparks when connecting the charger to the battery. The device will not deliver current if there is no battery detected (no voltage in the clamps). This charger is protected against handling errors by an internal fuse.
CONFIGURATION MENU
Navigation
Languages :
Selecting the display language.
Sound:
Turning the unit’s sound on (ON) or off (OFF).
Auto-Restart:
Enable (ON) or disable (OFF) the AUTO-RESTART function. This function
automatically restarts the charger in the event of a power failure.
Auto-Detect :
Enable (ON) or disable (OFF) the AUTO-DETECT function. This function
automatically starts a charge when a battery is connected to the charger.
Date :
Setting the date and time.
Cable calibration :
Procedure for calibrating the charging cables of the device, so that the
charger optimally compensates for the voltage drop due to the cables. It is
strongly recommended to perform this procedure at least once a year and each
time the charging cables are replaced.
Calibration procedure :
USB connectivity :
Sub-menu to access USB features.
Multi-Chargers Mode:
A function that allows multiple chargers to be parallelized to increase power.
Refer to the SHM – Smart Hub Module (025981) manual for more details. To
operate normally with a single charger, this feature must be set to OFF.
**USB CONNECTIVITY
**
Your GYSFLASH is equipped with USB connectivity that extends its functionality by creating custom configurations on your computer that can then be downloaded to the device via a simple USB stick. The custom configuration allows you to add, delete or modify charging modes and profiles, so that your charger can be adapted to your needs. USB connectivity also gives you the ability to retrieve the history and data of more than 100 recharge on a USB stick and run them on a spreadsheet
Navigation :
Import a new configuration:
This function allows you to download a new configuration («.gfc» file) into
the charger via the USB key.
Export a configuration on a USB key:
This function allows you to save the current charger configuration («.gfc»
file) to the USB stick.
Restore the previous configuration:
This function allows you to restore the second to last charger configuration
in case of a problem or error with the last downloaded configuration.
Export charging data on USB stick:
This function allows you to retrieve the charge history and data on a USB key,
in order to be able to use them on a spreadsheet or other
Custom configuration
List of modes and profiles available for customization
CHARGE MODE|
---|---
Charge
type:
| Charge
profiles
| Charging voltage
Pb-CHARGE
| normal| 2.40 V/cell| Charging profile for lead batteries of the types Gel, MF, EFB, SLA…
AGM
|
2.45 V/cell
| Charging profile for most AGM lead-acid batteries including START and STOP.
However, some AGM batteries require a lower voltage charge (Normal profile). Check the
battery manual if in doubt.
water| 2.45 V/cell| Charging profile for open liquid-type lead-acid batteries with plug.
Easy
|
2.40 V/cell
| Charging profile dedicated to lead batteries that automatically adapts the charging current according to the size of the battery.
However, for maximum charge optimization, it is recommended, when possible, to use
normal, AGM or liquid charge curves.
boost
|
2.42 V/cell
| Maximum current charge for lead-acid battery. This type of charge is ultra- fast. Warning : this type of charge must remain occasional in order to preserve bat- tery life.
recovery+
|
2.40 – 2.50 V/cell
| Charging profile for the recovery of severely damaged lead batteries. It is essential to recover the battery outside the vehicle to avoid damaging the vehicle electronics and in a well ventilated area.
Caution: Recovery voltage up to 4.0 V/cell.
Ca/Ca recov| 2.45 – 2.66
V/cell
| Charging profile for calcium battery recovery. The battery must be recovered outside the
vehicle to avoid damaging the vehicle’s electronics and in a well-ventilated area.
Caution: Recovery voltage can reach up to 2.75 V/cell.
Li-CHARGE
| LFP/LiFePO4| 3.60 V/cell| Charging profile for Lithium batteries type LFP
(Lithium Ferro Phosphate)
Li-ion std| 4.20 V/cell| Charging profile for standard lithium-ion batteries
based on Manganese or Cobalt (NMC,
LCO, LMO, MCO…)
LFP cell+| 3.60 V/cell| Charging profile dedicated to LFP (Lithium Ferro Phosphate) type lithium-ion cells with
selection of the number of cells in series to be charged.
Li-ion cell+| 4.20 V/cell| Charging profile dedicated to standard lithium-ion cells based on Manganese or Cobalt
(NMC, LCO, LMO, MCO…) with selection of the number of cells in series to be charged.
TRACTION| water| 2.42 V/cell| Charging profile dedicated to open lead traction
batteries for forklift trucks.
gel| 2.35 V/cell| Charging profile dedicated to gel-type traction batteries
for forklift trucks.
POWER MODES|
---|---
Showroom| Maintains the battery’s state of charge and supplies power when
using the electrical consumers of a demonstra- tion vehicle.
DIAG+| Supplies energy requirements during the vehicle diagnostic work.
CHANGE BAT.
| Allows to keep the vehicle power supply during battery replacement, in order to preserve the memory of the vehicle’s ECUs.
Caution: Reverse polarity during use can be harmful to the charger and vehicle electronics.
---|---
STARTER MODE| Starting aid for combustion vehicles. Allows the battery to be
precharged and the charger to send the maximum
current during the engine starting phase (the charger stops automatically after 30 minutes).
POWER SUPPLY
| Allows the charger to be used as an adjustable stabilized power supply with high power. The voltage to be regula- ted and the current limitation are fully adjustable.
Caution: Reverse polarity during use can be harmful to the charger and vehicle electronics.
Li-SUPPLY/LFP| Mode intended to supply lithium-ion cells of the LFP type
(Lithium Ferro Phosphate) with selection of the number of cells in series,
adjustment of the voltage and current to be applied.
Li-SUPPLY/Li-ion| Mode intended to supply standard lithium-ion batteries based
on Manganese or Cobalt (NMC, LCO, LMO, MCO…) with selection of the number of
cells in series, adjustment of the voltage and current to be applied.
MISCELLANEOUS|
---|---
TESTER MODE| Allows to check the state of the battery, to evaluate the
starting of the vehicle as well as the operation of the alternator
GYS offers you predefined configurations adapted to each application. These settings are available on the product page of the GYS website:
CONNECTIVITY MODULES
Your GYSFLASH is equipped with a DB9 type socket allowing you to connect various additional modules offered by GYS such as a printer, Ethernet or other module in order to further extend the possibilities of your charger.
LIST OF ERROR CODES
| Error code| Meaning| Solutions
---|---|---|---
1| Err01: Int_1 – Err02: Int_2 Err23: Int_3 – Err24: Int_4| Electronic problem
Defective charger| Contact the reseller
2| Err03: Fuse_NOK| Output fuse out of order| Have the fuse replaced by a
qualified person
3| Err04: T>Tmax| Abnormal overheating| Contact the reseller
4| Err05: (+)(-)| The polarity has been reversed on the clamps| Connect the
red clamp to the (+) and the black clamp to the (-) of the battery.
5| Err06: U> __ V| Overvoltage detected at the clamp terminals| Disconnect the
clamps
6| Err07: No_bat| Battery not connected| Check that the battery is correctly
connected to the charger
7
| ****
Err08: U< __ V
| ****
Abnormally low battery voltage
| Check that the selected mode is compatible with the battery
voltage (e. g. : 6 V battery in 24 V mode)
Charge the battery via CHARGE mode
Battery to be replaced
8| Err09: U> __ V| Abnormally high battery voltage| Check that the selected
mode is compatible with the battery
voltage (e. g. : 24 V battery in 12 V mode)
9| Err10: U>2.0V| Short-circuit detected during the charge process| Check the assembly
10
| ****
Err11: Time_Out
| Triggering the time limit| Presence of a consumer on the battery disrupting
the charge
---|---|---|---
Abnormally long charge| Battery to be replaced
11
| ****
Err12: Q> __ Ah
| ****
Tripping the overcharge protection
| Presence of a consumer on the battery disrupting the charge
Battery to be replaced
12| Err13: U< __ V| Abnormally low battery voltage when checking the charge|
Battery to be replaced
13
| ****
Err14: Bat_UVP
| Abnormally low battery voltage during UVP Wake up| Presence of a short
circuit, check the assembly
Battery to be replaced
14
| ****
Err15: U< __ V
| ****
Battery too low
| Check that the selected mode is compatible with the battery
voltage (e. g. : 24 V battery in 12 V mode)
Battery to be replaced
15| Err16: Bat_NOK| Battery out of order| Battery to be replaced
16| Err17: Recov_NOK| Battery recovery failure| Battery to be replaced
17| Err18: U>0V| Presence of a voltage at the clamp terminals when calibrating
the cables| Check the assembly
18
| ****
Err19: Cable_NOK
| ****
Cable calibration failure
| Charging cables to be replaced
Incorrect connection, check the assembly
19| Err20: U< __ V| Triggering of the abnormal undervol- tage protection|
Presence of a short circuit, check the assembly
20
| ****
Err21: U< V or Err22: U< V
| Abnormally low battery voltage during charging| Battery to be replaced
Presence of a consumer on the battery
21| ?| Key not detected| Check that the USB key is correctly connected to the
charger.
22| ?| No configuration file (.gfc) is present
on the key
| Check that your files are present at the root of the USB key. Do
not put them in a folder or sub-folder.
23| ****| Corrupted file| The file you wish to download is corrupted. Delete and reinstall the file on the key.
24
| ****
Err27: Cable_NOK
| ****
Multi-charger mode :
Parallel charging cables fail
| Load cables to be replaced.
Poor connection, check assembly (PHM).
To switch back to single charger operation, select OFF for the Multi-Charger
function.
25
| ****
Err28: COM_NOK
| ****
Multi-charger mode : Communication failure between chargers
| No communication, check SHM mounting and SLAVE X charger
configuration.
To switch back to single charger operation, select OFF for the Multi-Charger function.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
- Transit damage.
- Normal wear of parts (eg. : cables, clamps, etc..).
- Damages due to misuse (power supply error, dropping of equipment, disassembling).
- Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc …)
- A description of the fault reported
TECHNICAL FEATURES
| |
GYSFLASH 51.12 CNT FV
| GYSFLASH 101.12 CNT
GYSFLASH 103.12 CNT
| GYSFLASH 121.12 CNT FV GYSFLASH 123.12 CNT FV GYSFLASH 125.12 CNT FV| GYSFLASH 101.24 CNT FV
GYSFLASH 103.24 CNT FV
| GYSFLASH 51.48 CNT FV
GYSFLASH 53.48 CNT FV
---|---|---|---|---|---|---
Tension d’alimentation assignée Rated input voltage Netzspannung
Tensión de red asignada
| Номинальное напряжение питания
Nominale voedingsspanning Tensione di alimentazione nominale
|
100-240 VAC ~ 50/60Hz
|
220-240 VAC ~ 50/60Hz
|
220-240 VAC ~ 50/60Hz
100-127 VAC ~ 50/60Hz
|
220-240VAC ~ 50/60Hz
100-127VAC ~ 50/60Hz
Puissance assignée Rated power Bemessungsstrom Potencia asignada| Номинальная мощность Nominale vermogen Potenza nominale|
850 W
|
1600 W
|
2000 W (220-240Vac)
1500 W (100-127Vac)
|
3200 W (220-240Vac)
1500 W (100-127Vac)
|
3200W (220-240Vac)
1500W (100-127Vac)
Rendement Efficiency Wirkungsgrad Rendimiento| Производительность Opbrengst Rendimento|
93%
|
94%
|
90%
|
92%
Fusible d’entrée Input fuse Eingangssicherung| Входной плавкий предохранитель Zekering| T 10A|
–
|
–
Fusible de entrada| Fusibile d’entrata| (5×20)| |
Tensions de sortie assignées Rated output voltage Bemessungsspannung Tensiones
de salida asignadas| Номинальные выходные напряжения
Uitgaande nominale spanning Tensione di uscita nominale.
|
12 VDC
|
6 VDC
12 VDC
24 VDC
| 6 VDC
12 VDC
24 VDC
36VDC
48VDC
Plage de tension Voltage range Spannungsbereich Rango de tensión| Диапазон напряжения Spanningsbereik Intervallo di tensione|
2 – 32 V
|
2 – 16 V
|
2 – 32 V
|
2 – 64V
Courant de sortie assignée Rated output current Nennstrom
Corriente de salida asignada
| Номинальный выходной ток Uitgaande nominale spanning Corrente di uscita nominale|
50 A
|
100 A
|
120 A (220-240Vac)
100 A (100-127Vac)
| 100 A (220-240Vac)
50 A (24 VDC / 100-127Vac)
100 A (12 VDC / 100-127Vac)
| 50 A (220-240Vac)
25 A (48VDC / 100-127Vac)
50 A (24VDC / 100-127Vac)
Fusible de sortie| Выходной плавкий| | | |
Output fuse| предохранитель| | | |
Ausgangsicherung Fusible de salida| Zekering Fusibile d’uscita| 80 A| 125 A|
150 A| 80 A
|
Тип аккумулятора
Accu soort Tipo di batteria
| Plomb / Lithium-ion LFP – Standard
Type de batterie Battery type Batteriearte Tipo de batería| Lead-acid / LFP –
Standard Lithium-ion Blei-Säure / Lithium-ion LEP – Standard Plomo / Litio-ion
LFP – Standar
Свинец / Литий-железо-фосфат – Стандартный
Piombo / ioni di litio LFP – Standard
| Lood / Lithium-ion LFP – Standaard
Capacité assignée de batterie Rated battery capacity Nennkapazität der
Batterie Capacidad asignada de batería| Номинальная емкость батареи Nominale
accu capaciteit Capacità nominale della batteria|
10 – 600 Ah
|
20 – 1200 Ah
|
20 – 1500 Ah
|
20 – 1200 Ah
|
10 – 600 Ah
Consommation batteries au repos
Battery consumtion when idle
Rückstrom
Consumo de baterías en reposo
| Потребление АКБ в нерабочем состоянии
Accu verbruik in ruststand Consumo batterie in riposo
|
< 0.2 Ah / mois
FRONT
- Button Mode
- Buttons + or –
- Button Select
- Button Start/Stop
- Display
CONNECTORS
- Charging connector
- On/off switch
- Mains plug
- Connector for GYS additional module (type Sub-D 9)
- USB connector
GYS SAS 1, rue de la Croix des Landes CS 54159 53941 SAINT-BERTHEVIN Cedex France
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>