Carrier 50VL Comfort 13.4 SEER2 Single and Three Pase Air Conditioner System Owner’s Manual
- June 3, 2024
- Carrier
Table of Contents
Carrier 50VL Comfort 13.4 SEER2 Single and Three Pase Air Conditioner
System
NOTE TO EQUIPMENT OWNER:
For your convience, please record the model and serial numbers of your new
equipment in the spaces provided. This information, along with the
installation data and dealer contact information, will be helpful should your
system require maintenance or service.
Our products are designed, tested and built in accordance with DOE standardized procedures; however, actual operating results and efficiencies may vary based on manufacturing and supplier tolerances, equipment configuration, operating conditions and installation practices.
Safety Considerations
Improper installation adjustment, alteration, service, maintenance, or use can
cause explosion, fire, electrical shock, or other conditions which may cause
death, personal injury, or property damage. Consult a qualified installer,
service agency, or your distributor or branch for information or assistance.
The qualified installer or agency must use factory-authorized kits or
accessories when modifying this product Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing, and work
gloves. Use quenching cloth for brazing operations. Have a fire extinguisher
available. Read these instructions thoroughly and follow all warnings or
cautions included in literature and attached to the unit.
Consult local building codes, the current editions of the National
Electrical Code (NEC) NFPA 70.
In Canada refer to the current editions of the Canadian electrical Code CSA
C22.1.
Recognize safety information. This is the safety alert symbol . When you see
this symbol on the unit and in instructions or manuals, be alert to the
potential for personal injury. Understand these signal words;
DANGER, WARNING, and CAUTION. These words are used with the safety alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death.
WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
NOTE: Installer: This manual should be left with the equipment user.
WARNING
FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury, death, and/or
property damage.
Installation and servicing of this equipment can be hazardous due to
mechanical and electrical components. Only trained and qualified personnel
should install, repair, or service this equipment.
FIRE, EXPLOSION HAZARD
Failure to follow this warning could result in personal injury, death, and/or
property damage.
Do not store or use combustible materials, gasoline, or other flammable vapors
and liquids in the vicinity of this or any other appliance.
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury and/or death.
Before performing recommended maintenance, be sure the main power switch to
unit is turned off and lock-out tag is installed.
CAUTION
CUT HAZARD
Failure to follow this caution may result in personal injury.
When removing access panels or performing maintenance functions inside your
unit, be aware of sharp sheet metal parts and screws.
Although special care is taken to reduce sharp edges to a minimum, be
extremely careful and wear appropriate clothing, safety glasses and gloves
when handling parts or reaching into the unit.
WARNING
FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury, death or
property damage.
Do not use this unit if any part has been underwater. Immediately call a
qualified service technician to inspect the unit and to replace any part of
the control system which has been under water.
Starting or Shutting Unit Off
To start the unit:
- Turn on the electrical power supply to unit.
- Select temperature and set MODE control to desired mode.
To shut unit off:
NOTE: If the unit is being shut down because of a malfunction, call your
dealer as soon as possible.
- Set system MODE control to OFF.
- Turn off the electrical power supply to unit.
Operating Your Unit
The operation of your unit is controlled by indoor thermostat. You simply
adjust the thermostat and it maintains the indoor temperature at the level you
select. Most thermostats of cooling systems have 3 controls: a temperature
control selector, a FAN control, and a SYSTEM or MODE control. Refer to your
thermostat owner’s manual for more information.
To better protect your investment and to eliminate unnecessary service calls,
familiarize yourself with the following facts:
Cooling Mode
With the SYSTEM or MODE control set to COOL, your unit will run in cooling
mode until the indoor temperature is lowered to the level you have selected.
On extremely hot days, your unit will run for longer periods at a time and
have shorter “off” periods than on moderate days.
Heating Mode (if installed with optional electric heat)
Your system may also be equipped with an electric heating source. On cold days
and nights, place your MODE control to HEAT and your system will automatically
turn on the supplemental heat in order to maintain the level of comfort you
have selected.
Maintenance and Service
This section discusses maintenance that should be performed on your system.
Most maintenance should be performed by your dealer. You, as the owner, may
wish to handle some minor maintenance for your new unit.
Routine Maintenance
All routine maintenance should be handled by skilled, experienced personnel.
Your dealer can help you establish a standard procedure.
To assure proper functioning of the unit, flow of condenser air must not be obstructed from reaching the unit. Clearance from the top of the unit is 48 in. (1219 mm). Clearance of at least 36 in.(914 mm) is required on sides except the power entry side (42 in. [1067 mm] clearance) and the duct side (12 in. [305 mm] minimum clearance).
Maintenance and Care for the Equipment Owner
Before proceeding with those things you might want to maintain yourself, please carefully consider the following:
WARNING
FIRE, EXPLOSION, ELECTRICAL SHOCK AND CUT HAZARD
Failure to follow this warning could result in personal injury, death or
property damage.
- TURN OFF ELECTRICAL POWER TO YOUR UNIT BEFORE SERVICING OR PERFORMING MAINTENANCE.
- When removing access panels or performing maintenance functions inside your unit, be aware of sharp sheet metal parts and screws. Although special care is taken to reduce sharp edges to a minimum, be extremely careful when handling parts or reaching into the unit. Wear safety glasses, glove, and appropriate protective clothing.
Air Filters
The air filter(s) should be checked every 3 or 4 weeks and changed or cleaned
whenever it becomes dirty. Dirty filters produce excessive stress on the
blower motor and can cause the motor to overheat and shut down.
This unit must have air filters in place before it can be operated. These
filters can be located in one of at least two places. In many applications,
the installer will provide return air filter grilles mounted on the wall or
ceiling of the conditioned structure. In the instance of filter grilles, the
filters can simply be removed from the grille and replaced.
The other typical application is an accessory filter rack installed inside the
unit itself. The following information is given to assist in changing filters
used in these internal filter racks.
Filter kits are available as a purchased accessory or a factory-installed
option. The same filter kit is included with the accessory economizers and
factory installed economizers. See Table 1 for filter sizes supplied with
accessory filter rack.
Table 1 – Replacement Filter Sizes
Unit Size | Filter Size |
---|---|
24 | 2 each 20 x 12 x 1 |
(508 x 305 x 25 mm)
30| 2 each 20 x 12 x 1
(508 x 305 x 25 mm)
36| 1 each 24 x 18 x 1 (610 x 457 x 25 mm),24 x 16 x 1 (610 x 406 x 25 mm)
42| 1 each 24 x 14 x 1 (610 x 356 x 25 mm),24 x 16 x 1 (610 x 406 x 25 mm)
48| 1 each 24 x 18 x 1 (610 x 457 x 25 mm),24 x 16 x 1 (610 x 406 x 25 mm)
60*| 1 each 24 x 18 x 1 (610 x 457 x 25 mm),24 x 16 x 1 (610 x 406 x 25 mm)
Units with bent indoor coil.
To replace or inspect filters in accessory filter rack (See Fig. 2):
-
Remove the filter access panel using a 5/16-in. nut driver.
-
Remove the filter(s) by pulling it out of the unit. If the filter(s) is dirty, clean or replace with a new one.
When installing the new filter(s), note the direction of the airflow arrows on the filter frame, which should be pointed at the indoor coil. -
Reinstall filter access panel ensuring opening is air and water-tight.
If you have difficulty locating your air filter(s) or have questions concerning proper filter maintenance, contact your dealer for instructions. When replacing filters, always use the same size and type of filter that was supplied originally by the installer.
CAUTION
UNIT OPERATION HAZARD
Failure to follow this caution may result in property damage.
Never operate your unit without filters in place. An accumulation of dust and
lint on internal parts of your unit can cause loss of efficiency and blower
motor and/or compressor damage.
Replacing or inspecting filters in units with economizers
Small Chassis (See Fig. 3)
-
Remove return air duct cover at rear of unit using a 5/16-in. nut driver.
-
Remove the filter(s) by pulling it out and through the unit duct opening. If filter is dirty, replace both filters with new ones.
When installing the new filters, note the direction of the airflow arrows on the filter frame, which should be pointing at the indoor coil. -
Reinstall duct cover ensuring opening is air and water-tight.
Large Chassis (See Fig. 4)
-
Remove filter access door using a 5/16-in. nut driver.
-
Remove the filter(s) by pulling it out and through the unit filter access door. If filter is dirty, replace both filters with new ones.
Units with bent indoor coils, install 24 x 18 x 1 (610 x 457 x 25 mm) filter first and then install 24 x 16 x 1 (610 x 406 x 25) filter.
When installing the new filters, note the direction of the airflow arrows on the filter frame, which should be pointing at the indoor coil. -
Reinstall filter access door ensuring opening is air and watertight.
Fans and Fan Motors
Periodically check the condition of fan wheels and housings and fan-motor
shaft bearings. Contact your dealer for the required annual maintenance.
Indoor and Outdoor Coils
Cleaning of the coils should only be done by qualified service personnel.
Contact your dealer for the required annual maintenance.
Condensate Drain
The drain pan and condensate drain line should be checked and cleaned at the
same time the cooling coils are checked by your dealer.
Compressor
All compressors are factory shipped with a normal charge of the correct type
of refrigeration-grade oil.
Condenser Fan
WARNING
PERSONAL INJURY AND UNIT DAMAGE HAZARD
Failure to follow this warning could result in personal injury, death or
property damage.
Do not poke sticks, screwdrivers, or any other object into revolving fan
blades.
The fan must be kept free of all obstructions to ensure proper cooling.
Contact your dealer for any required service.
Electrical Controls and Wiring
Electrical controls are difficult to check without proper instrumentation.
If there are any discrepancies in the operating cycle, contact your local
dealer and request service.
Refrigerant Circuit
The refrigerant circuit is difficult to check for leaks without the proper
equipment. If inadequate cooling is suspected, contact your local dealer for
service.
WARNING
EXPLOSION, BURN AND ENVIRONMENTAL HAZARD
Failure to follow this warning could result in personal injury, death or
property damage.
System under pressure. Relieve pressure and recover all refrigerant before
system repair or final unit disposal. Use all service ports and open all flow-
control devices, including solenoid valves.
Unit Panels
After performing any maintenance or service on the unit, be sure all panels
are fastened securely in place to prevent rain from entering unit cabinet and
to prevent disruption of the correct unit airflow pattern.
Regular Dealer Maintenance (Also refer to Table 2)
In addition to the type of routine maintenance you might be willing to
perform, your unit should be inspected regularly by a properly trained service
technician. An inspection (preferably each year) should include the following:
- Inspection and, if required, cleaning of the outdoor and indoor coils.
- Inspection and, if required, cleaning of the indoor coil drain pan.
- Inspection and cleaning of blower wheel housing and motor.
- Inspection of all supply-air and return-air ducts for leaks, obstructions, and insulation integrity. Any problems found should be resolved at this time.
- Inspection of the unit base to ensure that no cracks, gaps, etc., exist which may cause a hazardous condition.
- Inspection of the unit casing for signs of deterioration.
- Inspection of all electrical wiring and components to assure proper connection.
- Inspection for leaks in the refrigerant circuit. Pressure check to determine appropriate refrigerant charge.
- Operational check of the unit to determine working conditions.
Repair or adjustment should be made at this time.
Your servicing dealer may offer an economical service contract that covers seasonal inspections. Ask for further details.
Complete service instructions can be found in the unit Installation, Start-up and Service Instructions.
Warranty Certificate
Your unit has a limited warranty. Be sure to read the warranty carefully to determine the coverage for your unit.
Before you call for service…
…check for several easily-solved problems.
If insufficient heating or cooling is suspected:
( ) Check for sufficient airflow. Check the air filter for dirt. Check for
blocked return-air or supply-air grilles. Be sure they are open and
unobstructed. If these checks do not reveal the cause, call your servicing
dealer.
If your unit is not operating at all, check the following list for easy solutions:
( ) Check to be sure that the temperature specified by your User
Interface is set below the indoor temperature during the cooling season or
above the indoor temperature during heating season. Be sure the User
Interface is set to COOL or HEAT and not OFF.
( ) If your unit still fails to operate, call your servicing dealer for
troubleshooting and repairs. Specify the model and serial numbers of your
unit. (Record them in this manual in the space provided.) If the dealer knows
exactly which unit you have, he may be able to offer suggestions over the
phone, or save valuable time through knowledgeable preparation for the service
call.
In Case of Trouble
If you perform the steps above and unit performance is still unsatisfactory,
shut off the unit and call your dealer.
Table 2 – Maintenance Checklist
Monthly maintenance items and outdoor unit rinsing may be performed by the
consumer. All other maintenance items and all service work must be
performed by a qualified service technician. Read all Warning labels.
Description of Maintenance | Recommended Interval |
---|---|
Consumer specific: | Monthly |
Inspect, clean, or replace air filter if filter is located indoors in return
air duct.| X|
Clear away debris and vegetation near unit.| X|
Dealer specific:| |
Inspect cabinet and basepan for damage. Replace panels, gaskets, and other
components that are damaged or severely rusted. Make sure precipitation has
not entered indoor section of unit.| | X
Inspect electrical disconnect for proper function. Repair or replace as
necessary.| | X
Inspect electrical wiring and connections. Tighten loose connections. Inspect
and perform functional test of equipment as needed to ensure proper function.
Repair or replace damaged or overheated components and wiring.| | X
Inspect electric heater, if installed. Check for signs of overheating of
elements, controls, and wiring. Make sure heater elements are not broken or
electically shorted.| | X
Check refrigerant system subcooling and/or superheat (system dependent).| | X
Inspect inside of unit. Clean if debris is present.| | X
Inspect condenser coil. Clean if dust, dirt, or debris is present. Rinse unit
with fresh water (see Note 2).| | X
Inspect condenser motor and fan for damage. Make sure fan spins freely.| | X
Inspect and clean blower assembly (includes blower housing, wheel, and
motor).| | X
Inspect evaporator coil. Clean if dust, dirt, or debris is present (see Note
2).| | X
Clean condensate pan and drain lines (more frequent maintenance may be
required in humid climates).| | X
Inspect airflow system (ductwork). Check for leaks and repair as needed.| | X
Notes:
- The above list may not include all maintenance items. Inspection intervals may vary depending on climate and operating hours. Consult your HVAC dealer about a service contract for seasonal inspections.
- Do not use harsh chemicals or high-pressure water on coils. More frequent rinsing is required for units near sea coast.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.