CLAGE DTK Digital Temperature Control Instruction Manual

June 3, 2024
CLAGE

CLAGE DTK Digital Temperature Control

CLAGE DTK Digital Temperature Control-fig1

Scope of delivery

  • 1 × Dual-fan
  • 1 × Controller
  • 1 × Inlet grille (cup board floor)
  • 1 × Inlet grille (sidewall / door)
  • 1 × Mounting part setCLAGE DTK Digital Temperature Control-fig2

Safety instructions

Please read these instructions carefully before installing or using the appliance! Keep the instructions handy with the appli­ance for future use!
Instruction manuals are intended for the specialist who is responsible for the installation of the appliance. Operation manuals are for the end user. The provided manuals correspond to the technical specifications of the appliance.
The latest version of the instructions can be found online at: www.clage.com/en/downloads

  • Do not use the appliance until it has been correctly installed and unless it is in perfect working order.
  • Never make technical modifications, either to the appliance itself or the electrical leads.
  • The appliance is only suitable for domestic use and similar applications inside closed rooms
  • The values stated on the rating plate must be observed.
  • This appliance can be used by children aged 3 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or ins truction concern-ing use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be performed by children without supervision.

Description of the appliance

  • The digital temperature controller for Zip devices (Art. no.: 893159) is used when cup-board temperatures are likely to exceed 30 °C and normal cupboard ventilation is not available.
  • The digital controller operates independently of the undersink unit and will require a separate 230 V GPO.
  • The controller is factory set to turn OFF at 33 °C and ON at 34 °C (recommended set-tings).
  • The differential between ON and OFF is locked at 1 °C however the set temp is user adjustable.
  • The current measured temperature is shown on the digital display in °C.

Installation

The following regulations must be observed

  • The rating plate and technical specifications
  • Only intact and appropriate tools must be used
  • Air inlet and the air outlet must be positioned at opposite ends of the same cupboard to ensure the best possible ventilation
  • It is important that controller and dual­fan are located in the warmest part (i.e. upper half), of the same cupboard, where the undersink unit is located

Mounting the appliance

  1. Attach the control unit as high as possible in the cupboard in which the Zip-device is installed. The installation is possible on top of the cabinet or the sidewall.
    Ensure that an electrical outlet is within reach of the connecting cable (max. 130 cm).

  2. If no air inlet is installed saw a cutout “A” for the inlet grille (sidewall / door) or a cutout “B” for the inlet grille (cup board floor) according to the drawing, cover it with the selected air inlet grille and secure it with screws.

  3. For the dual-fan saw the cutout “A” according to the drawing at the intended posi-tion.
    Ensure that the connecting cable of the dual­fan can reach the control unit (max. 145 cm).

  4. Turn the brackets by 90° to the inside (see below), to allow the fan can be pushed into the cutout “A” from the outside. Pay attention to the connecting cable of the fan, when inserting the fan through the cutout.

  5. After inserting the fan assembly, bend the brackets back through 90° to their origi-nal position and secure the fan assembly with 4 screws.

  6. Connect the dual-fan to the control unit via the connecting cable.

  7. Plug the plug of the control unit into a 230 V outlet.CLAGE DTK Digital Temperature Control-fig4

How to use

Change the temperature set point

  1. Press the SET button (1) once to change in the setting screen and view the current set point
  2. Use the keys to adjust the desired set point.
  3. Press the SET button (1) again to confirm the new set point and to return to normal screen.
    EG: If the set temperature is changed to 35 °C then the fan will switch ON at 36 °C an OFF at 35 °C.
    Note: Lowering the set point could result in the fan not turning OFF, therefore lowering the set point below the factory setting of 30 °C, is not recommended

Environment and Recycling

  • This product was manufactured climate neutrally according to Scope 1 + 2. We recom-mend the purchase of 100% green electricity to make the operation climate neutral as well.
  • Disposal of transport and packaging material: For smooth transport your product is carefully packed. The disposal of the transport material is carried out by the specialist tradesman or the specialist trade. Separate the sales packaging according to materials separated according to materials via one of the dual systems in Germany.
  • Disposal of old products: Your product was manufactured from high-quality, reusable materials and components. Products marked with the crossed-out wheeled bin symbol must be disposed of separately from household waste at the end of their service life. Therefore, take this product to us as the manufacturer or to one of the municipal collec-tion points that recycle used electronic devices. This proper disposal serves to protect the environment and prevents possible harmful effects on humans and the environ-ment that could result from improper handling of the products at the end of their ser-vice life. For more detailed information on disposal, please contact your nearest collec-tion point or recycling centre or your local council.
  • Business customers: If you wish to discard equipment, please contact your dealer or supplier for further information.
  • For disposal outside Germany, please also observe the local regulations and laws.

CLAGE GmbH
Pirolweg 4
21337 Lüneburg Deutschland
Telefon: +49 4131 8901-0 E-Mail: service@clage.de Internet: www.clage.de

Subject to technical changes, design changes and errors. 9120-91140 09.22