Omega OAPC41W 4.1kW Portable Air Conditioner User Manual

June 8, 2024
Omega

Omega-logo

Omega OAPC41W 4.1kW Portable Air Conditioner

Omega-OAPC41W-4.1kW-Portable-Air-Conditioner-product

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT: Read the safety precautions of this booklet carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage. If you are unsure about anything regarding your fan or these instructions, please contact Omega Altise on 1300 795 572 in Australia or (09) 415 6000 in New Zealand before operating your appliance.

  • This unit is not intended for use by children or infirm person without supervision.

WARNING: The Function Switch should not be used as the sole means of disconnecting power. Always unplug the power cord before servicing or moving the appliance.

  • The A-weighted sound pressure level is below 51 db.
  • The appliance shall be disconnected from its power source during service.
  • Always operate the unit from a power source of equal voltage, frequency and rating as indicated on the product identification plate.
  • Always use a power outlet that is grounded.
  • Do not operate with wet hands. Prevent water from spilling onto the unit.
  • Do not immerse or expose the unit to rain, moisture or any other liquid.
  • Do not leave the unit running unattended. Do not tilt or turn over the unit.
  • Do not unplug while the unit is operating.
  • Do not use an extension cord or an adapter plug.
  • Do not put objects on the unit.
  • Do not climb or sit on the unit.
  • Do not insert fingers or other objects into the air outlet.
  • Do not touch the air inlet or the aluminum fins of the unit.
  • Do not operate the unit if it is dropped, damaged or showing signs of product malfunction.
  • Do not clean the appliance with any chemicals.
  • Ensure the unit is far away from fire, inflammable, or explosive objects.
  • The unit shall be installed in accordance with national wiring regulations.
  • The appliance shall be stored in a room without continuously operation sources (for example: open flames, an operating gas appliance or an operating electric heater).
  • The appliance shall be stored so as to prevent mechanical damage from occurring.
  • Do not piece or burn, even after use.
  • Be aware that refrigerants may not contain an odour.
  • Pipework shall be protected from physical damage and shall not be installed in an unventilated space, if that space is smaller than 12 m².
  • Keep any required ventilation openings clear of obstruction.
  • Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry, recognized assessment specification.
  • Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
  • The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.

WARINNG: To avoid danger of electric shock, unplug from outlet when not in use and before cleaning. If the supply cord is damaged, it must be replaced by the manufacturer, its Service Agent or similarly qualified persons in order to avoid a hazard. In order to avoid overheating, do not cover the appliance. Do not use the appliance in the immediate surrounding of a bath, shower or swimming pool.

IMPORTANT SAFETY INSTRUCTIONS

  1. WARNING: flammable materials
  2. Service indicator, read technical manual
  3. Operator’s manual; operating instructions
  • This unit is not intended for use by children (including children) with reduced physical, sensory or metal capabilities, or lack of experience and knowledge, unless they been given supervision or instruction. Children being supervised not to play with the appliance.
  • Pipework shall be protected from physical damage and shall not be installed in an unventilated space, if that space is smaller than 13 m².
  • WARNING: Do not pierce or burn. Be aware that refrigerants may not contain an odour.
    • Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry, recognized assessment specification.
    • Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
    • The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
    • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture.
    • Do not place the appliance less than 50cm of free space around it to allow for proper air circulation.
    • The installation of pipework shall be kept to a minimum. The pipework shall be protected from physical damage. In case of field charge, the effect on refrigerant charge caused by the different pipe length has to be quantified.
    • The compliance with national gas regulations shall be observed.
    • The refrigerant shall only be charged at the manufacturing location or charged on site.
    • Maximum refrigerant charge 270g of R290.
    • Dusts connected to the appliance shall not contain a potential ignition source.
    • unventilated area where the appliance using flammable refrigerants is installed shall be so constructed that should any refrigerant leak, it will no stagnate so as to create a fire or explosion hazard.
    • The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
    • The appliance shall be stored in a room without continuously operating open flames (for example an operating gas appliance) and or other potential ignition sources (for example an operating electric heater, hot surfaces).

Repair to sealed components

  • During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
  • Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc.
  • Ensure that seals or sealing materials have not degraded to the point that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications.

Repair to intrinsically safe components

  • Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use.
  • Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating.
  • Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.

Cabling

  • Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects.

  • The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.
    Detection of flammable refrigerants

  • Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.

  • Electronic leak detectors may be used to detect refrigerant leaks but, in the case of flammable refrigerants, the sensitivity may not be adequate, or may need re-calibration.

  • Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed, and the appropriate percentage of gas (25 % maximum) is confirmed.

  • Leak detection fluids are also suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipework.

  • If a leak is suspected, all naked flames shall be removed/extinguished.

  • If a leakage of refrigerant is found which requires brazing, all of the refrigerants shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak.

Removal and evacuation

  • When breaking into the refrigerant circuit to make repairs – or for any other purpose –conventional procedures shall be used. However, for flammable refrigerants it is important that best practice is followed since flammability is a consideration. The following procedure shall be adhered to:
  • Remove refrigerant.
  • Purge the circuit with inert gas (optional for a2l).
  • Evacuate (optional for a2l).
  • Purge with inert gas (optional for a2l).
  • Open the circuit by cutting or brazing.

The refrigerant charge shall be recovered into the correct recovery cylinders. For appliances containing flammable refrigerants other than A2L refrigerants, the system shall be purged with oxygen-free nitrogen to render the appliance safe for flammable refrigerants. This process may need to be repeated several times. Compressed air or oxygen shall not be used for purging refrigerant systems.

  • For appliances containing flammable refrigerants, other than A2L refrigerants, refrigerants purging shall be achieved by breaking the vacuum in the system with oxygen-free nitrogen and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final oxygen-free nitrogen charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipework are to take place.
  • Ensure that the outlet for the vacuum pump is not close to any potential ignition sources and that ventilation is available.

Charging procedures

  • In addition to conventional charging procedures, the following requirements shall be followed:
  • Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
  • Cylinders shall be kept in an appropriate position according to the instructions.
  • Ensure that the refrigerating system is earthed prior to charging the system with refrigerant.
  • Label the system when charging is complete (if not already).
  • Extreme care shall be taken not to overfill the refrigerating system.
  • Prior to recharging the system, it shall be pressure-tested with the appropriate purging gas. The system shall be leak-tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.

Decommissioning

  • Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of recovered refrigerant. It is essential that electrical power is available before the task is commenced.
    • (a) Become familiar with the equipment and its operation.
    • (b) Isolate system electrically.
    • (c) Before attempting the procedure, ensure that:
    • Mechanical handling equipment is available, if required, for handling refrigerant cylinders.
    • All personal protective equipment is available and being used correctly.
    • The recovery process is supervised at all times by a competent person.
    • Recovery equipment and cylinders conform to the appropriate standards.
    • (d) Pump down refrigerant system, if possible.
    • (e) If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
    • (f) Make sure that cylinder is situated on the scales before recovery takes place.
    • (g) Start the recovery machine and operate in accordance with instructions.
    • (h ) Do not overfill cylinders (no more than 80 % volume liquid charge).
    • Do not exceed the maximum working pressure of the cylinder, even temporarily.
    • When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
    • (k) Recovered refrigerant shall not be charged into another refrigerating system unless it has been cleaned and checked.

Labelling

  • Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. For appliances containing flammable refrigerants, ensure that there are labels on the equipment stating the equipment contain flammable refrigerant.
  • When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely.

Recovery

  • When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e., special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure-relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
  • The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of all appropriate refrigerants including, when applicable, flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt.
  • The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant waste transfer note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.
  • If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.

Warnings for Disposal
Refrigerant used for the air-conditioner are flammable. Therefore when the air-conditioner is scraped, it shall be kept away from any fire source and be recovered by a special recovering company with corresponding qualification other than be disposed by combustion, so as to prevent damage to the environment or any other harm.

Correct Disposal of this product
This marking indicates that this product should not be disposed with other household wastes. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.

TECHNICAL DETAILS

Model OAPC41W
Fan Speeds 3 settings
Cooling Capacity 14000 Btu/h (4.10 KW)
Cooling Rated Input Power 1.560KW
Cooling Rated Input Current 6.9A
Power Supply 220-240V/50Hz-60Hz
Refrigerant R290 , 0.27Kg
IP Code IPX1
MAXIMUM SUCTION/EXHAUST SIDE WORKING PRESSURE 0.7MPa/3.2MPa

Maximum permissible

pressure on the high/low pressure side

| ****

3.2Mpa

Heat exchanger maximum allowable pressure| 3.2Mpa
Sound Power Level| ≤65dB(A)
Net Weight| 31Kg
Dimensions| 470x353x762mm

FEATURES

  • High Capacity in a compact size with cooling, dehumidifying and ventilating function
  • Temperature setting and display
  • LED Digital display
  • Electronic control with built-in timer, sleep mode
  • Self-evaporating system for better efficient
  • Auto shut off when tank full
  • Automatic restart in the event of power outage
  • Auto defrosting function at low ambient temperatures
  • Remote control
  • 3- speed fan
  • Casters for easy mobility

PRODUCT OVERVIEW

Omega-OAPC41W-4.1kW-Portable-Air-Conditioner-
FIG-1

  1. Control Panel
  2. Air outlet with adjustable louver
  3. Air outlet with adjustable louver
  4. Power cord
  5. Recessed handle
  6. Air exhaust
  7. Drain opening with sealing plug

Note: The appearance is only for reference. Please see the real product for detailed information.

INSTALLATION INSTRUCTIONS

UnpackingOmega-OAPC41W-4.1kW-Portable-Air-Conditioner-
FIG-2

  • Unpack the carton and take the appliance and accessories out.
  • Check the device after unpacking for any damage or scratches on it.

Accessories:

  1. Exhaust hose
  2. Hose connector
  3. Window kit adapter
  4. Remote control
  5. Window kit

Choose your location

  • If tipped more than 45°, allow the unit to set upright for at least 24 hours before starting up.
  • Place the unit on a firm, level surface in an area with at least 50cm of free space around it to allow for proper air circulation.
  • Do not operate in close proximity to walls, curtains, or other objects that may block air inlet and outlet. Keep the air inlet and outlet free of obstacles.
  • Never install the unit where it could be subject to:
    • Heat sources such as radiators, heat registers, stoves or other products that produce heat.
    • Direct sunlight
    • Mechanical vibration or shock
    • Excessive dust
    • Lack of ventilation, such as cabinet or bookcase
    • Uneven surface

WARNING

  • install the unit in rooms which exceed 4 m².
  • Do not install the unit in a place where inflammable gas may leak.

ATTACH THE EXHAUST HOSE
The air conditioner requires being vented outside so that the exhaust air can escape the room which coming from the appliance contains waste heat and moisture.
Do not replace or extend exhaust hose which will result in decreased efficiency, even worse shut down the unit due to low backpressure.
Step 1: Connect the hose connector to one end of the exhaust hose.
Step 2: Connect the windows kit adapter to the other end of the exhaust hose.
Step 3: Extend the adjustable window kit the length of your window. Connect the exhaust hose to the window kit.
Step 4: Close your window to secure the kit in place. It needs to hold the windows kit firmly in place, secure the window kit with duct tape if required. It is recommended that the gap between the adapter and the sides of the window should be sealed off for maximum efficiency.
Step 5: Attach the hose connector to the exhaust air outlet of unit .Omega-OAPC41W-4.1kW-Portable-Air-Conditioner-FIG-9
Step 6: Adjusting the length of the flexible exhaust hose and avoid bends in the hose. Then place AC near an electrical outlet.
Step 7: Adjust the louver at the air outlet, and then switch on the unit.

OPERATING INSTRUCTIONS

CONTROL PANEL AND DISPLAYOmega-OAPC41W-4.1kW-Portable-Air-Conditioner-
FIG-11

1. POWER (LED) Press to switch the machine on or off.
2. MODE Mode button Press to switch the operation mode

between cool, fan, and dry.

3.| INDICATORS| LED for four operation modes selecting by press mode button.
4.| ADD| Increasing the desired temperature(16℃~32℃)

or timer setting.

5.| SWING| Adjust the air flow direction vertically.
6.| TIMER| Sets a time for the unit to automatically start or stop.
7.| FAN| Press to switch the fan speed in HIGH(green) 、

middle(green)and LOW (green)

8.| INDICATORS| LED for fan speed (Low, middle and high)
9.| DIGITAL DISPLAY| Displays timer setting and room temperature.
10.| MINUS| Decreasing the desired temperature or timer setting.
11.| SLEEP| Press to turn sleep mode on or off.

REMOTE CONTROL

Omega-OAPC41W-4.1kW-Portable-Air-Conditioner-FIG-12

START-UP AND SHUTDOWN

  • Press POWER button to turn the unit on.
  • The unit runs in a FAN mode as default.
  • Press MODE button to select the desired operation mode.
  • Press POWER button again to turn off the power.

OPERATION MODE

The unit has four operation modes: Cool, fan, dry and sleep (Sleep mode is only optional on the remote control

COOLING MODE

  • Select the cool mode to lower the temperature in your room.
  • Press MODE button repeatedly until the LED of COOL operation lights up.
  • Press ADD/MINUS button to adjust the temperature which is displayed on the screen. The temperature can be set between 16℃ and 32℃.
  • Press SPEED button repeatedly until the desired fan speed indicator lights up.
  • To control the direction of the air flow horizontally, press the SWING button.

Note: The air conditioner stops if the room temperature is lower than selected temperature.

VENTILATION MODE

  • Press MODE button repeatedly until the LED of FAN operation lights up.
  • In ventilation mode the room air is circulated, but not cooled.
  • Press SPEED button repeatedly to select the fan speed as desired.

DRY MODE

  • Press MODE button on the control panel or remote control, the LED of DRY operation lights up.
  • The fan speed is unable to select. User should connect the hose to the drain outlet at the bottom of the unit.
    Note: In this mode, the fan speed switches over to low speed and the temperature cannot be selected.

SLEEP MODE
The sleep mode can be activated when in cool mode.

In cool mode
After 1 hour the pre-set temperature is increased by 1 ℃, after another hour the pre-set temperature will again be increased by 1 ℃.

TIMER SETTING
The timer has two ways of operation:

AUTOMATIC DEFROST
At low room temperatures, frost may build-up at the evaporator during operation. The unit will automatically start defrosting and the POWER LED blinking. The defrost control sequence is as follows:

  • When the unit operates in the cooling operation, drying operation, the ambient temperature sensor senses the evaporator coil temperature is below -1°C, after the compressor will stop operating for 10 minutes or the coil temperature up to 7 °C, the unit restart to cool operating mode.
  • When the unit operates in the drying operation, once the coil temperature sensor senses the temperature of the evaporator is below 40°C and the differential temperature between coil temperature and room temperature is below 19°C after the compressor operation for 20 minutes, the unit start defrosting for 5 minutes and the power indicator blinking.

OVERLOAD PROTECTION
In the event of a power loss, to protect the compressor there is a 3-minute delay until the compressor restarting.

DRAINAGE (Self- evaporating system)
The self-evaporating system uses the collected water to cool the condenser coils for better efficient performance. There is no need to empty the drainage tank in cooling operation except in drying operation and high humidity conditions. The condensate water evaporates at the condenser and evacuated through the exhaust hose.
For continuous operation or unattended operating in drying, please connect the attached drain hose to the unit. Condensate water can be automatically flow into a bucket or drain by gravity.

  • Switch off the unit before operating.
  • Remove the plug of the water outlet opening and keep it in safe area.
  • Securely and properly connect the drain hose and make sure it is not kinked and clear of obstruction.
  • Place the outlet of hose over a drain or bucket and ensure that water could freely flow out of the unit.
  • Do not submerge the end of hose into water; otherwise, it can cause “Air Lock” in the hose.

To avoid water spillage:
As the negative pressure of condensate drain pan is large, tilt the drain hose downward toward the floor. It is appropriate that the degree of inclination should exceed 20 degrees.
Straighten the hose to avoid a trap existing in the hose.

CLEANING

WARNING

  • Cleaning and maintenance shall not be made by children without supervision.
  • Cleaning of this appliance should be done every two weeks.
  • Always make sure that the appliance is completely dry before connecting back to the mains supply.
  • Make sure no water enters the control panel or fan motor.
  • Store the appliance in a cool dry place.

Dust collects on the filter and restricts the airflow. The restricted airflow reduces the efficiency of the system and if it becomes blocked it can cause damage to the unit.
The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not operate the unit without an air filter, or the evaporator may be contaminated.

  1. Press POWER button to switch off the unit and unplug the power cord.
  2. Remove the filter mesh from the unit.
  3. Use a vacuum cleaner to suck dust from the filter.
  4. Turn the filter over and rinse the air filter under running water. Let the water run through the filter in the opposite direction of air flow. Set aside and allow the filter to air dry completely before reinstalling.Omega-OAPC41W-4.1kW-Portable-Air-Conditioner-FIG-16

Warning: Do not touch the evaporator surface with bare-hand or could cause injury of your fingers.

CAUTION: Do not use gasoline, benzene, thinner, harsh cleaners, etc. as they will damage the appliance. NEVER use ALCOHOL OR SOLVENTS.

CLEANING UP OF REFRIGERANT
  1. Gas/vapor heavier than air. May accumulate in confined spaces, particularly at or below ground level.
  2. Eliminate every possible source of ignition.
  3. Use appropriate personal protection equipment (PPE).
  4. Evacuate unnecessary personnel, isolate, and ventilate area.
  5. Do not get in eyes, on skin, or on clothing. Do not breathe vapours or gas.
  6. Prevent entry to sewers and public waters.
  7. Stop the source of the release, if safe to do so. Consider the use of water spray to disperse vapours.
  8. Isolate the area until gas has dispersed. Ventilate and gas test area before entering. Contact competent authorities after a spill.

SERVICING
Please follow these warnings when to undertake the following when servicing an appliance with R290.

Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.

Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is being performed.

General work area
All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the work space shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.

Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. no sparking, adequately sealed or intrinsically safe.

Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.

No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.

Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance.
The following checks shall be applied to installations using flammable refrigerants:

  • The charge size is in accordance with the room size within which the refrigerant containing parts are installed.
  • The ventilation machinery and outlets are operating adequately and are not obstructed.
  • If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant.
  • Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected.
  • Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.

Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.

Initial safety checks shall include:

  • Those capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking.
  • That there no live electrical components and wiring are exposed while charging, recovering or purging the system.
  • That there is continuity of earth bonding.

WARNING

  • Install the unit in rooms which exceed 12 m².
  • Do not install the unit in a place where inflammable gas may leak.

TROUBLESHOOTING

Do not repair or disassemble the unit by yourself, unauthorized repair attempts will invalidate the warranty and may cause bodily harm.

Symptom Inspection Solution

The unit is not operating.

| Check the power connection in securely.| Insert the power cord securely into the wall outlet.
Check if the water level indicator lights up?| Empty the drain pan by remove the rubber plug.

Check the room temperature.

| The range of operating temperature is 5-35℃.

The unit works with reduced capacity.

| Check the air filter for dirt.| Clean the air filter as necessary.
Check if the air duct is blocked.| To clear the obstacle.
Check if the room door or window is open.|

Keep the door and windows closed.

Check if the desired operating mode is selected and the temperature is properly set.| Set the mode and temperature at proper set-point according to the manual.

The exhaust hose is detached.

| Make sure the exhaust hose is securely attached.

Water Leakage

|

Overflow while moving the unit.

| Empty the water tank before transport.
Check if the drain hose is kinked or bends.| Straighten the hose to avoid a trap existing.

Excessive Noise

| Check if the unit is securely positioned.| Place the unit on horizontal and firm ground.
Check if any loose, vibrating parts.| Secure and tight the parts.

Noise sounds like water flowing.

| Noise comes from flowing refrigerant. This is normal.

Error Code

| E0| Communication faults between main PCB and display PCB.| Check the wire harness of the display PCB for damage.

E1

|

Ambient temperature sensor failure

| Check connection or replace it. To clean or replace the temperature sensor.

E2

|

Coil temperature sensor failures.

| Check connection or replace it. To clean or replace the temperature

sensor.

Ft|

Condensate water high level alarm.

| Empty the drain pan by removal the rubber plug.

If the above solutions do not resolve the problem please contact the service centre.
It is important that you retain these instructions, proof of purchase as well as other important documents about this product for future reference. Due to continual product development, Omega Altise reserves the right to alter specifications or appearances without notice. Dispose of packaging responsibly – recycle where facilities are available.

WARRANTY

AUSTRALIAN CUSTOMERS
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

NEW ZEALAND CUSTOMERS
Nothing herein contained shall be construed in any way as excluding or limiting your rights under the
Consumer Guarantee Act 1993.

Our Warranty
This product is also covered by the manufacturer’s warranty set out in this document (Our Warranty). Our Warranty is for a period of thirty six (36) months from the date of purchase. This is in addition to (and does not exclude, restrict or modify) any rights or remedies to which you may already be entitled under the Australian Consumer Law or the New Zealand Consumer Guarantee Act 1993 relating to this product.

Our Warranty (which is subject to the conditions below) covers rectification free of charge of any fault arising from defective materials or components, or faulty workmanship. The product will be repaired or replaced at the option of Omega Altise.

OUR WARRANTY: is subject to the following conditions:

  1. That the purchaser contact Omega Altise prior to any product repair.
  2. That the purchaser carefully follows all instructions provided with the product and complies with all relevant electrical & plumbing regulations in their State when installing the product.
  3. That the purchaser carefully follows the instructions provided in the owner’s handbook relating to the proper use and care of the product and does not use the product for any purpose other than the DOMESTIC use for which it has been designed. If the appliance is used in commercial applications or for rental purposes, Our Warranty is limited to a warranty of Twelve (12) months covering all parts with Three (3) months on any labour cost of service or repair.

WHAT IS COVERED: By Our Warranty:
During the warranty period, Omega Altise or its authorised Service Centre will at no extra charge, if your
appliance is readily accessible without the need of special equipment and subject to the terms and conditions of this warranty, repair or replace any parts which it considers defective.

WHAT IS NOT COVERED: By Our Warranty:

  1. Products installed damaged or incomplete or not in compliance with the relevant electrical & plumbing regulations in their State.
  2. Normal wear and tear e.g. cleaning, filters etc.
  3. Failure resulting from power surges and electrical storms.
  4. Insect or vermin infestation.
  5. Unauthorised repairs or use of non-genuine parts.
  6. Any failure caused by the product not being used in accordance with the instruction and the installation manual provided with the product.
  7. Misuse or abuse, including failure to properly maintain or service.
  8. The clearing of lint, hair or dirt from within the appliance.
  9. Damage which occurs during delivery or installation.
  10. Claims to product surface coating due to liquid or solid spill-overs, accidental damage or damage caused from cleaning products not recommended by Omega Altise.

HOW TO CLAIM OUR WARRANTY
Please refer to our website address below for Shriro Australia in Australia or Monaco Corp in New Zealand to
register your warranty online. If you are contacting us regarding any warranty claims and spare part enquiries, please make sure you have the following information on hand:

  1. Product Name/Model Number
  2. Serial Number
  3. Purchase Date (as per invoice, or proof of purchase)
  4. Purchased from
  5. Warranty Registration Number

IN AUSTRALIA
Omega Altise is a division of Shriro Australia Pty Limited ABN 28 002 386 129
Customer care: 1300 739 033
Email: customercare@shriro.com.au
Web: www.omegaaltise.com.au
IN NEW ZEALAND
Omega Altise is a division of Monaco Corporation Ltd (Member of Shriro Australia PTY LTD)
Phone (09) 415 6000
Email: customercare@monacocorp.co.nz
Web: www.omegaaltise.com.au

address: A division of Shriro Australia Pty Ltd 2-34 Davidson Street Chullora NSW 2190
In Australia: 1300 795 572
In New Zealand: (09) 415 6000
www.omegaaltise.com
IM Ref: OAPC41W 2021/09/02