INTRODUCTION

Thank you for purchasing this RUNPOTEC RUNPOMETER RM35. These instructions for use provide information on safe use. Read the instructions for use thoroughly before commissioning. If you have any questions about commissioning, assembly, safety and applications, or problems, please contact your authorized retailer or RUNPOTEC. You will find our contact data on page 2. See page 4 – 5 for application examples.

IMPORTANT INFORMATION

The RUNPOMETER RM35 is exclusively used for length measurements of cables and other yard goods.
Liability is excluded for every other use!
Before measuring, check the measuring wheel for wear and tear.

RUNPOMETER RM35 DESCRIPTION/ACCESSORIES

  1. Button for opening

  2. Cable inlet or cable outlet opening

  3. 1.5″ LCD display

  4.  USB-C charger socket

  5. Index mark – Start/end point for measurement

  6. Tempered measuring wheel

  7. Guide jaws for precise measurement (2 x 6/24 mm + 2 x 12/18 mm)

  8. Bolt for mounting on mounting plate system case or for fastening a belt with a clip system and anchor pad

  9. RUNPOTEC system case with RUNPOMETER RM35 case insert

  10. Anchor pad

  11. Longitudinally adjustable belt with clip system

  12. Mounting plate for fixing on the RUNPOTEC system case

  13. Power adapter with USB-C charger cable

DISPLAY KEYS DESCRIPTION

A Menu settings
B Set a plus value
C Set a minus value
D Reset measured values
E ∑ Total 1 – (added measured values) = display TOTAL 1
F ∑ Total 2 – (added measured values) = display TOTAL 2
G Current measured value / counter value (positive/negative)
H Actual – counts up to the preset countdown value
I Countdown (adjustable)
J Pulling direction display
K Meter / Feet – displays the set unit
L Display backlighting on/off
M Audible signal on/off
N Battery state of charge

TECHNICAL SPECIFICATIONS

Display unit Meters (optionally feet)
Max. length. 99999.99 m / 99999.99 ft
Smallest display value 0.01 m
Cable cross-section min. 2 mm / max. 32 mm
Max. speed. 1 m/s
Measuring wheel diameter 25 mm ± 0.02 mm
Measuring accuracy Accuracy class III
Measurable length min. 5 m
Intended location open
Ambient conditions Temperature: -10 °C to +40 °C Air humidity: no

condensation
Mechanical: Class M2
Electromagnetic: Class E1
Protection class| IP 44

CONFORMITY ASSESSMENT

The RUNPOMETER RM35 complies with the requirements of the Measuring
Instruments Directive MID 2014/32/EU (conformity assessment procedure with type test according to module B).
EU type examination certificate number A 0445/2020-0.752.468/2021

REQUIREMENTS FOR THE MEASURED MATERIAL

  • Round cross-section

  • Smooth surface

  • No kinks

  • Does not elongate or crush

  • Dry and unsoiled

INSTRUCTIONS FOR USE

General information

Switch on by pressing any button. 10 minutes after the last interaction, the RUNPOMETER switches off again.
(The time can be changed in the menu settings – 5. AutoOFF time)
Standby mode – Activates 1 minute after last interaction – switch back on by pressing any button or moving the measuring wheel.
(The time can be changed in the menu settings – 4. Standby time)

Display/keys

E ∑ 1 (Total 1) – ∑ 2 (Total 2) – After pressing the respective button, the current
F counter reading (positive or negative) is added to TOTAL 1 or TOTAL 2 and the current counter reading is set to 0.
Hold the button in question down for 3 sec. to reset the value to 0.

MEASURED VALUE DISPLAY +/- (positive/negative)
RES button D hold down for 3 seconds to reset the value to 0.

ACTUAL – Counts down the set countdown value to 0 in the pull direction and outputs an audible signal. Then restarts.

COU N TDOWN – Preset the desired measuring length.
Adjust with the Plus B /Minus C keys.
Fine adjustment – short press – fast adjustment – hold down.
Disables the countdown function – resets the value to 0.

Press and hold the A menu button for 2 sec. to open the settings (if there is no activity, the settings menu is closed after 30 sec.). Press the A menu button again to browse the settings. To change the current setting, press the Plus B / Minus C keys. The value is saved.

  1. Display intensity – backlighting
  2. Duration of display backlighting
  3. Audible signal volume
  4. Standby time – Time until standby mode is activated – the display is switched off after this. The device can be reactivated by moving the measuring wheel or pressing any button.
  5. AutoOFF – time, time to automatic shutdown (from the start of standby mode to completely switching off)
  6. Meter/Feet – the selected unit of measure flashes
  7. Software version – current software version
    Absolute measured length in kilometres (CAUTION – guide value only)

GUIDE FOR A MEASUREMENT

Open the lid of the RUNPOMETER with the 1 locking button on the side. Select and install the guide jaws 2 (see Using the guide jaws). Insert the cable to be measured and close the instrument lid. Align cable start flush with front housing surface. Note the index mark (arrow)! 5

Reset the measured value to 0 (hold RES button D down for 3 seconds). Pull the cable slowly and evenly by hand to the desired length/length to be measured. Read off the measured value/cut the cable, the front housing surface is the index mark.

Index mark 5 – Arrow marks front housing surface of the device as measuring reference (start/end point for measurement).

USING THE GUIDE JAWS

Select guide jaws for the respective cable diameter according to the table below. Insert in pairs, with the selected diameter facing up, into the holes provided.

Cable cross-section     Guide jaws

Ø 2 – 6 mm| Ø 6 mm – red
Ø 7 – 12 mm| Ø 12 mm – grey
Ø 13 – 18 mm| Ø 18 mm – grey
Ø 19 – 24 mm| Ø 24 mm – red
Ø 25 – 32 mm| Without guide jaws

USE OF ACCESSORIES SYSTEM CASE MOUNTING PLATE

The RUNPOMETER RM35 can be attached to the RUNPOTEC system case for stationary operation by means of a mounting plate.

  1. Open the folded system case mounting plate by pressing the red button.

  2. Place on case, engage to case on one side.

  3. Fix the system case mounting plate on the other side with the red case locking mechanism. (Fold the red locking mechanism up).

  4. Insert/engage the device into/in the holder provided for this purpose.
    Mounting Plate
    To remove the device: press the red button, remove the device.

APPLICATION STRAP WITH CLIPSYSTEM

  1. Clip the clip into the RUNPOMETER RM35 with the red button pressed.
  2. Belt length adjustable from 750 mm to 1200 mm.
  3. Clip the clip into the XBOARD XB300 / XB500 with the red button pressed
    Application Strap with Clip system

APPLICATION ANCHOR PAD

  1. Clip the clip into the anchor pad with the red button pressed.
  2. Place the cable drum roller Pro 530/670 on the anchor pad.
    Anchor Pad

APPLICATION EXAMPLES

  • RM35 with Clip system in the cable store
    Application Example

  • RM35 with mounting plate-case, Cable assembly

  • RM35 with XB 300 and multi-function mandrel with individual wires
    Application Example

  • RM35 with mounting plate-case, cable pulling system Ø 4,5 mm

  • RM35 with XB 500 and CAT Cable

  • RM35 with PRO 530 and 5 x 2,5 mm2 Cable
    Application Example

  • RM35 foldable with 5 x 16 mm2 underground cable

  • RM35 with RUNPOLIFTER L1600 and 1 x 300 mm2 cable
    Application Example

Support

RUNPOTEC GmbH
Irlachstrasse 31
A-5303 Thalgau
Tel.: +43-6235-20335
Fax: +43-6235-20335-35
office@runpotec.com
www.runpotec.com

VIDEO

RUNPOMETER DEUTSCH

VIDEO

RUNPOMETER ENGLISH

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals