RUNPOTEC RM35 Runpo Meter Digital Cable Length Measuring Device Instruction Manual

June 6, 2024
RUNPOTEC

RUNPOTEC RM35 Runpo Meter Digital Cable Length Measuring Device

INCLUDING ACCESSORIES

RUNPOTEC-RM35-Runpo-Meter-Digital-Cable-Length-
Measuring-Device-1RUNPOTEC-RM35
-Runpo-Meter-Digital-Cable-Length-Measuring-Device-2

DISPLAY DESCRIPTION

APPLICATION

APPLICATION STRAP WITH CLIPSYSTEM

RUNPOTEC-RM35-Runpo-Meter-Digital-Cable-Length-Measuring-
Device-4

  1. Clip the clip into the RUNPOMETER RM35 with the red button pressed.
  2. Belt length adjustable from 750 mm to 1200 mm.
  3. Clip the clip into the XBOARD XB300 / XB500 with the red button pressed.

APPLICATION ANCHOR PAD

RUNPOTEC-RM35-Runpo-Meter-Digital-Cable-Length-Measuring-
Device-5

  1. Clip the clip into the anchor pad with the red button pressed.
  2. Place the cable drum roller Pro 530/670 on the anchor pad.

APPLICATION EXAMPLES

RM35 with Clipsystem in the cable store

RM35 with mounting plate-case, Cable assembly

RM35 with XB 300 and multi-function mandrel with individual wires

RM35 with mounting plate-case, cable pulling system Ø 4,5 mm

RM35 with XB 500 and CAT Cable

RM35 with PRO 530 and 5 x 2,5 mm2 Cable

RM35 foldable with 5 x 16 mm2 underground cable

RM35 with RUNPOLIFTER L1600 and 1 x 300 mm2 cable

INTRODUCTION

Thank you for purchasing this RUNPOTEC RUNPOMETER RM35. These instructions for use provide information on safe use. Read the instruc tions for use thoroughly before commissioning. If you have any questions about commissioning, assembly, safety and applications, or problems, please contact your authorised retailer or RUNPOTEC. You will find our contact data on page 2. See page 4 – 5 for application examples.
IMPORTANT INFORMATION
The RUNPOMETER RM35 is exclusively used for length measurements of cables and other yard goods. Liability is excluded for every other use! Before measuring, check the measuring wheel for wear and tear.
RUNPOMETER RM35 DESCRIPTION/

ACCESSORIES

  1. Button for opening
  2. Cable inlet or cable outlet opening
  3. 1.5″ LCD display
  4. USB-C charger socket
  5. Index mark – Start/end point for measurement
  6. Tempered measuring wheel
  7. Guide jaws for precise measurement (2 x 6/24 mm + 2 x 12/18 mm)
  8. Bolt for mounting on mounting plate system case or for fastening a belt with a clip system and anchor pad
  9. RUNPOTEC system case with RUNPOMETER RM35 case insert
  10. Anchor pad
  11. Longitudinally adjustable belt with clip system
  12. Mounting plate for fixing on the RUNPOTEC system case
  13. Power adapter with USB-C charger cable

DISPLAY KEYS DESCRIPTION

  1. Menu settings
  2. Set a plus value
  3. Set a minus value
  4. Reset measured values
  5. ∑ Total 1 – (added measured values) = display TOTAL 1
  6. ∑ Total 2 – (added measured values) = display TOTAL 2
  7. Current measured value / counter value (positive/negative)
  8. Actual – counts up to the preset countdown value
  9. Countdown (adjustable)
  10. Pulling direction display
  11. Meter / Feet – displays the set unit
  12. Display backlighting on/off
  13. Audible signal on/off
  14. Battery state of charge

TECHNICAL SPECIFICATIONS

  • Display unit: Meters (optionally feet)
  • Max. length: 99999.99 m / 99999.99 ft
  • Smallest display value: 0.01 m
  • Cable cross-section: min. 2 mm / max. 32 mm
  • Max. speed: 1 m/s
  • Measuring wheel diameter: 25 mm ± 0.02 mm
  • Measuring accuracy: Accuracy class III
  • Measurable length: min. 5 m
  • Intended location: open
  • Temperature: -10 °C to +40 °C
  • Air humidity: no condensation
  • Mechanical: Class M2
  • Electromagnetic: Class E1
  • Protection class: IP 44

CONFORMITY ASSESSMENT
The RUNPOMETER RM35 complies with the requirements of the Measuring Instruments Directive MID 2014/32/EU (conformity assessment procedure with type test according to module B). EU type examination certificate number A 0445/2020-0.752.468/2021

REQUIREMENTS FOR THE MEASURED MATERIAL

RUNPOTEC-RM35-Runpo-Meter-Digital-Cable-Length-Measuring-
Device-14

  • Round cross-section
  • Smooth surface
  • No kinks
  • Does not elongate or crush
  • Dry and unsoiled

INSTRUCTIONS FOR USE

General information

Switch on by pressing any button. 10 minutes after the last interaction, the RUNPOMETER switches off again. (The time can be changed in the menu settings – 5. AutoOFF time) Standby mode – Activates 1 minute after last interaction – switch back on by pressing any button or moving the measuring wheel. (The time can be changed in the menu settings – 4. Standby time)

Display/keys

  •  1 (Total 1) – ∑ 2 (Total 2) – After pressing the respective button, the current counter reading (positive or negative) is added to TOTAL 1 or TOTAL 2 and the current
  • counter reading is set to 0. Hold the button in question down for 3 sec. to reset the value to 0.
  • MEASURED VALUE DISPLAY +/- (positive/negative) RES button D hold down for 3 seconds to reset the value to 0.
  • ACTUAL – Counts down the set countdown value to 0 in the pull direction and outputs an audible signal. Then restarts.
  • COUNTDOWN – Preset the desired measuring length. Adjust with the Plus B /Minus C keys. Fine adjustment – short press – fast adjustment – hold down. Disables the countdown function – resets the value to 0.

Menu settings

Press and hold the A menu button for 2 sec. to open the settings (if there is no activity, the settings menu is closed after 30 sec.). Press the A menu button again to browse the settings. To change the current setting, press the Plus B /Minus C keys. The value is saved.

  1. Display intensity – backlighting
  2. Duration of display backlighting
  3. Audible signal volume
  4. Standby time – Time until standby mode is activated – the display is switched off after this. The device can be reactivated by moving the measuring wheel or pressing any button.
  5. AutoOFF – time, time to automatic shutdown (from the start of standby mode to completely switching off)
  6. Meter/Feet – the selected unit of measure flashes
  7. Software version – current software version Absolute measured length in kilometres (CAUTION – guide value only)

GUIDE FOR A MEASUREMENT

RUNPOTEC-RM35-Runpo-Meter-Digital-Cable-Length-Measuring-
Device-15

Open the lid of the RUNPOMETER with the 1 locking button on the side. Select and install the guide jaws 2 (see Using the guide jaws). Insert the cable to be measured and close the instrument lid. Align cable start flush with front housing surface. Note the index mark (arrow)! 5 Reset the measured value to 0 (hold RES button D down for 3 seconds). Pull the cable slowly and evenly by hand to the desired length/length to be measured. Read off the measured value/cut the cable, the front housing surface is the index mark

Index mark 5: Arrow marks front housing surface of the device as measuring reference (start/end point for measurement).

USING THE GUIDE JAWS
Select guide jaws for the respective cable diameter according to the table be- low. Insert in pairs, with the selected diameter facing up, into the holes provided.

RUNPOTEC-RM35-Runpo-Meter-Digital-Cable-Length-Measuring-
Device-16

USE OF ACCESSORIES SYSTEM CASE MOUNTING PLATE

The RUNPOMETER RM35 can be attached to the RUNPOTEC system case for stationary operation by means of a mounting plate.

  1. Open the folded system case mounting plate by pressing the red button.
  2. Place on case, engage to case on one side.
  3. Fix the system case mounting plate on the other side with the red case locking mechanism. (Fold the red locking mechanism up).
  4. Insert/engage the device into/in the holder provided for this purpose. To remove the device: press the red button, remove the device.RUNPOTEC-RM35-Runpo-Meter-Digital-Cable-Length-Measuring-Device-20

RUNPOTEC GmbH – Irlachstrasse 31 – A-5303 Thalgau

Tel: +43-6235-20 335

Fax: DW 35

office@runpotec.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals