Danfoss 421529-3 Vane Type Triple Pump Owner’s Manual
- June 3, 2024
- Danfoss
Table of Contents
421529-3 Vane Type Triple Pump
Owner’s Manual
421529-3 Vane Type Triple Pump
10. SAE rated capacity (V10 cover end cartridge)
USgpm| Rotor| V ane Kit
(12 vanes)| Ring| Pin (V10S)| Pin (V10F/V10P)| Bolt
(V10S)| Bolt (V10F)| Bolt (V10P)| Cartridge Kit
---|---|---|---|---|---|---|---|---|---
1| 317681| 923499| 317674| 2456| 2456| 11156| 295344| 295344| 923471
2| 317675| 923470
3| 317676| 923496
4| 351247| 923500| 317677| 16662| 16662| 1278| 432511| 432511| 923469
5| 317678| 923468
6| 357286| 923501| 355641| 179341| 179341| 432509| 295346| 295346| 923497
7| 331813| 923498
9. V10 port connection
Code | V10S Cover V1 | 0F Cover V10 | P Cover |
---|---|---|---|
P | 372863 | 379543 | ____ |
R | 372864 | ____ | ____ |
S | 372865 | ____ | ____ |
Y | 377829 | ____ | ____ |
T | ____ | 372851 | ____ |
K | ____ | ____ | 388262 |
Pressure setting
V10P/V10F (Omit for V10S)
Code| Pressure setting V10P/V10F| V10P Spring| V10F control
valve S/A
---|---|---|---
A| 250 psi| 252886| 229613
B| 500 psi| 2280| 233018
C| 750 psi| 232794
D| 1000 psi| 2282| 232795
E| 1250 psi
232796
F| 1500 psi| 2281| 232797
G| 1750 psi| 232798
H| 2000 psi| 232799
J| 2250 psi| 233019
K| 2500 psi| 233020
SAE rated capacity
(**20 VQ center cartridge)
USgpm| Ring| Inlet Plate| Rroto| Vane Kit| F3
Cart. Kit
---|---|---|---|---|---
5| 333624| 419502| 402690| 922741| 574918
8| 333625| 574920
9| 374799| 574921
11| 333626| 419501| 403539| 922745| 574922
12| 353901| 574923
14| 353902| 574924
** Included in 25 VQ shaft end cartridge kit.
** Included in 20 VQ center cartridge kit.
Included in V10 cover end cartridge kit.
Included in seal kit 920166. (Kit contains F3 components & both shaft
seals.)
Included in flex side plate kit; bronze face of plate must be installed
toward the rotor. Kit also contains four seal packs.
Assemble seal with spring loaded sealing member towards bearing. Seals
to be completely wetted with oil prior to assembly.
**** Install 419673 & 419672 sealing ring into body, then install cartridge
kit.
6. SAE rated capacity (25VQ shaft end cartridge)**
USgpm | Ring | F3 Cart. Kit |
---|---|---|
10 | 326989 | 02–125589 |
12 | 326984 | 421570 |
14 | 326985 | 421571 |
16 | 424084 | 578174 |
17 | 326986 | 421572 |
19 | 326987 | 421573 |
21 | 326988 | 421574 |
7. Port connections
Connection Type| Body Kit| Inlet Cover| Rear Mounting
Cover
---|---|---|---
A – 4 Bolt Flange (Inch)| 02–136915| 251263| 572822
AM – 4 Bolt Flange (Metric)| 02–136916| 478505| 860778
NOTE: Body kit includes body, ball, and plug. (Ball and plug not shown)
Model Code
-
Special seals
F3 – Vition ”O”Rings and shaft seals -
Pump series designation
25VQ – Shaft end pump
20VQ – Center pump -
Body mounting flange
S – SAE mounting per J –744 101 –2 -
Pump series designation
V10 cover end pump -
V10 pump cover options
S – Standard cover
F – Flow control and relief cover
P – Priority valve and relief cover -
SAE rated capacity (VQ shaft – end cartridge)
Code
10 – 10 USgpm
12 – 12 USgpm
14 – 14 USgpm
16 – 16 USgpm
17 – 17 USgpm
19 – 19 USgpm
21 – 21 USgpm -
VQ port connections (inlet & outlet #1 & #2)
A – 4 bolt flange (inch threads)
AM – 4 bolt flange (metric threads) -
SAE rated capacity (VQ center cartridge)
Code
5 – 5 USgpm
6 – 6 USgpm
8 – 8 USgpm
9 – 9 USgpm
11 – 11 USgpm
12 – 12 USgpm
14 – 14 USgpm -
V10 port connections
V10S standard covers and outlet # 3
Code
S – .750 –16 Str. thd.
P –½ ” – NPT thd.
Y – .875 –14 Str. thd.
R – 1.062 –12 Str. thd.
V10F flow/relief control cover Code| Outlet # 3| Tank port
---|---|---
T – .750| –16 Str. thd| .750 –16 Str. thd.
P – .750| –16 Str. thd.| ½ ” – NPT thd.
V10P priority control covers
Code| Primary port Str. Thd| Secondary port Str. thd.| Tank
port Str. Thd
---|---|---|---
K| .5625 –18| .750 –16| .5625 –18
10. SAE rated capacity (V10 cover end cartridge)
Code
1 – 1 USgpm
2 – 2 USgpm
3 – 3 USgpm
4 – 4 USgpm
5 – 5 USgpm
6 – 6 USgpm
7 – 7 USgpm
-
Shaft seal
Blank – Single seal
S – Double seal -
Shaft type
297 – All series -
Port orientation (Outlet #1)
(Viewed from cover end of pump; refer to table on next page) -
Port orientation (Outlet #2)
(Viewed from cover end of pump; refer to table on next page) -
Port orientation (Outlet #3 or primary outlet)
(Viewed from cover end of pump; refer to table on next page) -
Controlled flow rate, V10F & V10P (Omit for standard cover)
Code
3 – 3 USgpm
4 – 4 USgpm
5 – 5 USgpm
6 – 6 USgpm
7 – 7 USgpm
8 – 8 USgpm -
Relief valve pressure setting, V10F & V10P (Omit for standard cover)
Code A – 250 psi
B – 500 psi
C – 750 psi
D – 1000 psi
E – 1250 psi| F – 1500 psi
G – 1750 psi
H – 2000 psi
J – 2250 psi
K – 2500 psi
---|--- -
Design (Subject to change)
-
Rotation (Viewed from shaft end of pump)
L – Left hand for counterclockwise
R – Right hand for clockwise
NOTE
V10 cover can be assembled in any of four positions refer to drawing M –2005
–S.
13. 14. 15. Port orientation cod (Viewed from cover end of pump)
Outlet | 13 #1 | 14 #2 | 15 #3 |
---|---|---|---|
Opposite inlet | A | A | |
135° CCW from inlet | A | ||
90° CCW from inlet | B | B | |
45° CCW from inlet | B | ||
Inline with inlet | C | C | |
45° CW from inlet | C | ||
90° CW from inlet | D | D | |
135° CW from inlet | D |
Sharp Edges of Vane Must Lead in Direction of Rotatio
NOTE
To reverse cartridge kit rotation, remove the two screws and reverse the
location of the inlet support plate and the outlet support plate. Reinstall
the two screws hand tight. Use pump cover to align all sections of the
cartridge. Carefully remove the cover and tighten the screws.
When ordering spare cartridge parts, it is recommended they be obtained in
cartridge kits. Kits are assembled and tested for either right or left hand
rotation. If left hand rotation is required, it should be specified on parts
order by adding suffix ”L” to cartridge kit number.
Products we offer
• Cartridge valves
• DCV directional control valves
• Electric converters
• Electric machines
• Electric motors
• Gear motors
• Gear pumps
• Hydraulic integrated circuits (HICs)
• Hydrostatic motors
• Hydrostatic pumps
• Orbital motors| • PLUS+1® controllers
• PLUS+1® displays
• PLUS+1® joysticks and pedals
• PLUS+1® operator interfaces
• PLUS+1® sensors
• PLUS+1® software
• PLUS+1® software services, support and training
• Position controls and sensors
• PVG proportional valves
• Steering components and systems
• Telematics
---|---
Danfoss Power Solutions is a global manufacturer and supplier of high-
quality hydraulic and electric components. We specialize in providing state-
of-the-art technology and solutions that excel in the harsh operating
conditions of the mobile off-highway market as well as the marine sector.
Building on our extensive applications expertise, we work closely with you to
ensure exceptional performance for a broad range of applications. We help you
and other customers around the world speed up system development, reduce costs
and bring vehicles and vessels to market faster.
Danfoss Power Solutions – your strongest partner in mobile hydraulics and
mobile electrification.
Go to www.danfoss.com for further product
information.
We offer you expert worldwide support for ensuring the best possible solutions
for outstanding performance. And with an extensive network of Global Service
Partners, we also provide you with comprehensive global service for all of our
components.
Local address:
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.co
Danfoss
Power Solutions (US) Company
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239 6000| Danfoss
Power Solutions Trading (Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd
Jin Qiao, Pudong New District
Shanghai, China 201206
Phone: +86 21 2080 6201
---|---
Danfoss
Power Solutions GmbH & Co. OHG
Krokamp 35
D-24539 Neumünster, Germany
Phone: +49 4321 871 0| Danfoss
Power Solutions ApS
Nordborgvej 81
DK-6430 Nordborg, Denmark
Phone: +45 7488 2222
Danfoss can accept no responsibility for possible errors in catalogues,
brochures and other printed material. Danfoss reserves the right to alter its
products without notice. This also applies to products already on order
provided that such alterations can be made without subsequent changes being
necessary in specifications already agreed.
All trademarks in this material are property of the respective companies.
Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights
reserved.
© Danfoss
September 2022
AX435174899874en-000101
M–2494–S
Released 08–01–95
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>