AS Synthesizers AS201 Lowpass VCF and VCA Analogue Filter and Amplifier Module User Manual

June 16, 2024
AS Synthesizers

AS Synthesizers AS201 Lowpass VCF and VCA Analogue Filter and Amplifier

Module User Manual

BLOCK DIAGRAM OF LOWPASS VCF & VCA

100% ANALOG MODULE

  1. V/OCT CV input, range: 0V to +10V,
  2. FREQ CV1 input, range: -10V to +10V
  3. FREQ CV2 input, range: -10V to +10V
  4. RESO CV input, range: 0V to +10V,
  5. VCA CV input, range: 0V to +10V
  6. VCF audio in 1, level: 10Vpp
  7. VCF audio in2, level: 10Vpp
  8. VCF audio in 3, level: 10Vpp
  9. VCF audio out
  10. VCA audio out
  11. Freq CV1 depth: 0 to 100%
  12. Freq CV2 depth: 0 to 100%
  13. Reso CV depth: 0 to 100%
  14. Level of VCF audio in 1: 0 to 100%
  15. Level of VCF audio in 2: 0 to 100%
  16. Level of VCF audio in 3: 0 to 100%
  17. Cutoff freq potentiometer
  18. Resonance potentiometer
  19. VCF slope switch
  20. VCF drive indicator
  21. Q compensatin switch
  22. FREQ CV2 to VCA CV switch

BACK PANEL OF

LOWPASS VCF & VCA

AS201 100% ANALOG MODULE

  1. Power bus connector IDC10

  2. Initial tune

  3. V/OCT scale trim

  4. Multimeter probe pins

  5. CV inputs from internal rails

  6. VCF inputs from internal rails When no use of input pins, connect
    jumper between input and GND also between V/OCT IN and V/OCT REF pins

  7. VCF & VCA outputs to internal rails Do not use jumpers on output

pins, also do not connect to ground orpower rails!

TECHNICAL SPECIFICATION:

Module depth: 33mm
Module width: 16HP (80.4mm) Module weight: 215g
Connector type: 10P IDC Eurorack Power consumption:
+12V / 60mA & 12V / 50mA
Audio in & out: HQ Audio Audio in & out range: 10Vpp
CV inputs: 0V to +10V or -5V to +5V
CALIBRATION: The best results for filter range, the voltage on “SCALE” probe should be maintained -25mV and +155mV
This voltage difference is 180mV

  1. Turn down all knobs into fully CCW position, disconnect cables from V/OCT Take care of the jumper to be connected between V/OCT IN and V/OCT REF pins on backside of the module
  2. Power on your modular system, and wait a few minutes for warm up
  3. Connect multimeter’s GND probe to any GND pin, or Next, connect multimeter’s positive probe to “SCALE” probe
  4. Turn Cutoff Freq knob into fully CCW position, measure +155mV
  5. Turn Cutoff Freq knob into fully CW position, measure -25mV
  6. In case you see different value, then turn “SCALE” trimmer until voltage difference between full CCW and full CW becomes 180mV
  7. Now turn “INIT” trimmer until measure +155mV at full CCW of Cutoff Freq knob, and -25mV at full CW,

Enjoy