AS Synthesizers AS201 Lowpass VCF and VCA Analogue Filter and Amplifier Module User Manual
- June 16, 2024
- AS Synthesizers
Table of Contents
AS Synthesizers AS201 Lowpass VCF and VCA Analogue Filter and Amplifier
Module User Manual
BLOCK DIAGRAM OF LOWPASS VCF & VCA
100% ANALOG MODULE
- V/OCT CV input, range: 0V to +10V,
- FREQ CV1 input, range: -10V to +10V
- FREQ CV2 input, range: -10V to +10V
- RESO CV input, range: 0V to +10V,
- VCA CV input, range: 0V to +10V
- VCF audio in 1, level: 10Vpp
- VCF audio in2, level: 10Vpp
- VCF audio in 3, level: 10Vpp
- VCF audio out
- VCA audio out
- Freq CV1 depth: 0 to 100%
- Freq CV2 depth: 0 to 100%
- Reso CV depth: 0 to 100%
- Level of VCF audio in 1: 0 to 100%
- Level of VCF audio in 2: 0 to 100%
- Level of VCF audio in 3: 0 to 100%
- Cutoff freq potentiometer
- Resonance potentiometer
- VCF slope switch
- VCF drive indicator
- Q compensatin switch
- FREQ CV2 to VCA CV switch
BACK PANEL OF
LOWPASS VCF & VCA
AS201 100% ANALOG MODULE
-
Power bus connector IDC10
-
Initial tune
-
V/OCT scale trim
-
Multimeter probe pins
-
CV inputs from internal rails
-
VCF inputs from internal rails When no use of input pins, connect
jumper between input and GND also between V/OCT IN and V/OCT REF pins -
VCF & VCA outputs to internal rails Do not use jumpers on output
pins, also do not connect to ground orpower rails!
TECHNICAL SPECIFICATION:
Module depth: 33mm
Module width: 16HP (80.4mm) Module weight: 215g
Connector type: 10P IDC Eurorack Power consumption:
+12V / 60mA & 12V / 50mA
Audio in & out: HQ Audio Audio in & out range: 10Vpp
CV inputs: 0V to +10V or -5V to +5V
CALIBRATION: The best results for filter range, the voltage on “SCALE” probe
should be maintained -25mV and +155mV
This voltage difference is 180mV
- Turn down all knobs into fully CCW position, disconnect cables from V/OCT Take care of the jumper to be connected between V/OCT IN and V/OCT REF pins on backside of the module
- Power on your modular system, and wait a few minutes for warm up
- Connect multimeter’s GND probe to any GND pin, or Next, connect multimeter’s positive probe to “SCALE” probe
- Turn Cutoff Freq knob into fully CCW position, measure +155mV
- Turn Cutoff Freq knob into fully CW position, measure -25mV
- In case you see different value, then turn “SCALE” trimmer until voltage difference between full CCW and full CW becomes 180mV
- Now turn “INIT” trimmer until measure +155mV at full CCW of Cutoff Freq knob, and -25mV at full CW,