What’s in the Box

EMTEK Modern Styles Electronic Deadbolt Lock Sets-1

ITEM NO. DESCRIPTION QTY.
1 Key 2
2 Outside Trim Plate Assembly 1
3 Deadbolt Latch Assembly 2 3/8” or 2 3/4” Backset 1
4 Inside Trim Plate Assembly 1
4a Inside Chassis 1
4b Inside Trim Plate 1
4c #8-32 x 3/8” Flat Head Machine Screw 2
4d 9V Alkaline Battery 1
5 #8-32 x 11/2” Flat Head Machine Screw 2
6 #8 x 3/4” Wood Screw 4
7 Strike Plate 1
8 Security Plate 1
9 #10 x 3” Wood Screw 2

Preparation

  1. Door Prep
  2. Door Jamb Prep
    Step 1: Fasten Security Plate using two #10 x 3” Wood Screws (item #9).
    Step 2: Fasten Strike Plate using two #8 x 3/4” Wood Screws (item #6).

How to Install

Install Latch

Fasten Latch using two #8 x 3/4” Wood Screws (item #6).

THE LATCH ASSEMBLY MUST BE ORIENTED AS SHOWN AND THE BOLT MUST BE IN THE RETRACTED POSITION FOR INSTALLATION.

EMTEK Modern Styles Electronic Deadbolt Lock Sets-4

Remove Screws from Inside Trim Plate

Use a Phillips head screwdriver to remove screws (item #4c) shown below and detach Inside Trim Plate from the Inside Chassis.

REMOVE INSIDE CHASSIS FROM TRIM PLATE BEFORE INSTALLING THE OUTSIDE TRIM. THUMBTURN MUST BE IN UNLOCKED POSITION.

EMTEK Modern Styles Electronic Deadbolt Lock Sets-5

Install Outside Trim Plate Assembly

Position the Outside Trim Plate Assembly through the bore hole.

ONCE POSITIONED, OUTSIDE TRIM PLATE ASSEMBLY REQUIRES SUPPORT.

Install Inside Chassis

Step 1: Confirm the position of Flat Shaft.

HOLE FOR FLAT SHAFT MUST BE IN VERTICAL POSITION FOR INSTALLATION.

Step 2: Feed the Wire Harness through Inside Chassis.

EMTEK Modern Styles Electronic Deadbolt Lock Sets-8

Step 3: Fasten Inside Chassis using two #8-32 x 11/2” Flat Head Machine Screws (item #5).

EMTEK Modern Styles Electronic Deadbolt Lock Sets-9

Step 4: Connect Wire Harness (A) and tuck Connectors as shown (B).

Step 5: Install Battery.

EMTEK Modern Styles Electronic Deadbolt Lock Sets-11

Install Inside Trim Plate

Fasten Inside Trim Plate using two #8-32 x 3/8” Flat Head Machine Screws (item

4c).

*Unlocked position is required for installation and removal of the Inside
Trim Plate Assembly.

EMTEK Modern Styles Electronic Deadbolt Lock Sets-13

How to Use

Your Lock is Ready to Use

Your Emtek lock is shipped with two 4-digit user codes and a 6-digit programming code. These codes are randomly generated at the factory.
(Turn to next page for Programming Instructions.)

To Unlock:

  1. Enter 4-digit user codes.
    (See sticker located on the inside trim plate or on page 11).

  2. Rotate Thumbturn.

To Lock:

  1. Press EMTEK key.
  2. Rotate Thumbturn.
How to Program

Programming Your Lock
In order to perform each of the following six functions, the lock must first be placed in Programming Mode:
*If no input within 10 seconds, Yellow LED goes out, Red LED flashes and lock exits Programming Mode.

  1. Press and hold EMTEK button for 3 seconds
  2. Yellow LED flashes, then remains solid*, number keys also illuminate
  3. Enter Programming Code
  4. Yellow LED flashes, then 1 beep
  5. Yellow LED remains solid (awaiting button press; see following Table)

EMTEK Modern Styles Electronic Deadbolt Lock Sets-16

If no input within 10 seconds, Yellow LED goes out, Red LED flashes and lock exits Programming Mode.

Also referred to as “vacation mode”. This command temporarily disables all user codes (metal key override will still work).

Keypad Operation – Beeper & LED Indicators

EMTEK Modern Styles Electronic Deadbolt Lock Sets-17

If 3 consecutive incorrect codes are entered, the lock emits 4 short beeps and a flashing Red EMTEK button. The lock will not accept additional input for 20 seconds (20 beeps). When the next valid code is entered the lock will beep quickly 10 times to alert of the incorrect codes.
Battery voltage has dropped too low; keypad will be disabled but metal key override will still work.

Restoring the Lock to Factory Default Setting

This procedure clears the lock of all users and restores the Programming Code and 2 User Codes shipped with the lock.

  • Remove power (disconnect 9V battery) from Lock
  • Press and Hold EMTEK button
  • While continuing to hold EMTEK button, restore power (reconnect 9V battery)
  • Continue to hold EMTEK button for 3 seconds
  • 1 Green LED Flash and 2 short beeps followed by 1 Green LED Flash and 2 short beeps indicates the lock has been successfully restored

U.S. patents:
8,176,761
8,141,4000

Canadian patents:
2,698,041
2,789,278
2,789,280o

Emtek Products
Tel: 800-356-2741. 626-961-0413
Fax: 800-577-5771 626-336-2812
emtek.com

Copyright © Emtek Products, ASSA ABLOY Residential Group Inc. DBA Emtek Products, 2021
Reproduction in whole or in part without the express written permission of Emtek Products is prohibited.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Emtek User Manuals

Related Manuals