INSTALLATION INSTRUCTIONS
CAMBRIDGE®
AMERICAST BRAND
2460 SERIES/2461 SERIES WHIRLPOOL / BATHING POOL
GENERAL SPECIFICATIONS FOR 2460/2461 WHIRLPOOL
INSTALLED SIZE.————– 60 x 32 X 17-3/4 In. (1524 x 813 x 451mm)
WEIGHT.———————— 142 Lbs. (64 Kg.) WEIGHT wi
WATER—————- 550 Lbs. (254 Kg.)
GAL. TO OVERFLOW——————– 50 Gal. (190 L)
WHIRLPOOL MIN. OPERATING VOL.——————————— 39 Gal. (143 1)
BATHING WELL AT SUMP.—————– 41×20 In. (1041 x 508mm)
BATHING WELL AT RIM—————————- 54%26 In. (1372 x 660mm)
WATER DEPTH TO OVERFLOW.———————– 14 In. (336mm)
FLOOR LOADING—————————- 41Lbs./Sq.Ft. (200 Kgs./Sq.m) (PROJECTED AREA)
PTS.———————– 139
CUBE (FT9)————————- 309
WHIRLPOOL ELECTRICAL SPECIFICATIONS 2460/2461.028 & .128
SYSTEM PUMP.————————- 14 HPR, 75 AMPS, 120V,
SAFETY HEATER————————— 12 AMPS, 120V.
GENERAL INSTALLATION INF ORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before enclosing with wallboard, tile, etc., water test the unit and check for leaks
Do not make modifications to the whirlpocl system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations) Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
FOR AFTER-SALES SERVICE CALL 1
800-442-1902 WEEKDAYS.
THANK YOU…
for selecting an American Standard bath. Your new bath is shipped to you after
careful inspection. The whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the installation are your
selected fittings and electrical connections for a whirlpool.
To Ensure maximum performance and pleasure from this product, please follow the instructions and cautions.
List of Optional Components (not included):
- Safe-T-Heater 9075.120″
- see your American Standard Distributor
List of Required Components (not included):
- Drain 1583.470″
- Bath Filler*
- see your American Standard Distributor
List of Required Tools and Supplies:
Tools
- Level
- Tape Measure
- Pipe Wrench
- Slip Joint Pliers
- Screw Driver
- Standard Woodworking Tools
- Personal Safety Equipment
- Caulking Gun
Supplies
- Nails
- Putty
- Caulking (waterproof)
- 1x3o0r2x4 Stringers
- Drop Cloth
- 15 amp GFCI Qutlet
- Cement, Plaster, Grout
FRAMING AND INSTALLATION
Bath may only be installed above the floor line in a recess types installation, as shown in recess installation diagram.
Locate studs as required. Insure rough dimensions are proper, plumb and square. For whirlpools, provision must be made in all installations for an access opening for ser ing pump and controls.
- The following procedure must be used for all installations: leveling support stringer should be as indicated.
- The bath is supported from the apron and the rear tiling flange. No support under the sump is necessary.
- Position bathtub/whirlpool within the recess, check level, front to back, side to side, and shim as necessary.
- Also check drain clearance hole in the subfloor.
- To secure the tub to wood studs use roofing nails immediately above the flange of the tub.
- To secure the tub to steel studs use drywall screws and flatwashers.
Caution: take extra care when driving nails or screws to avoid damaging the
tub.
The tile or similar finished floor will be butted against the bottom of the
tub apran, also holding the tub in place.
TYPICAL RECESS INSTALLATION
WHIRLPOOL ONLY:
UNLESS AN ACCESS OPENING OF AT LEAST 12″ X 24″ (305 X 610MM) IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED.
SUGGESTED WHIRLPOOL/BATH INSTALLATION METHOD
STEEL STUDS
SECURE THE BATH TO THE STUDS AS SHOWN FOR WOOD OR STEEL STUD ‘CONSTRUCTION.
ELECTRICAL INSTALLATION INSTRUCTIONS
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.
WARNING:
When using electrical products, basic precautions should always be observed,
including the following:
-
DANGER: RISK OF ELECTRIC SHOCK
Connect only to a circuit protected by a ground-fault circuit interrupter. -
Grounding is required. The unit should be installed by a licensed electrician and grounded.
-
Install to permit access for servicing.
-
All building materials and wiring should be routed away from the pump body and heater (if equipped).
The whirlpool should be installed on a 120 vac, 15 amp dedicated circuit. The circuit should be hard-wired from the electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential. ADDING THE SAFE-T-HEATER REQUIRES A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT.
ELECTRICAL INSTALLATION
WIRE SELECTION GUIDE
Motor Hi-Performance Rating 1.4
Maximum distance from fusebox to motor
50′| 100’| 150″| 200’
120V Power Line
12| 12| 10| 8
The sizes shown on this chart are recommendations for copper conductors only. Always follow local and national electrical codes
DRAIN CONNECTION AND SYSTEM TEST
Using recommended drain opening, connect whirlpool drain to waste line. Tighten all drain joints securely.
Check the pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with water to a point 2″ above the top of the highest jet. Recheck the pump couplings and make certain that they are not leaking. (Although the pump couplings are factory tightened and inspected, some loosening may have occured during transit.) Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on.
Check for leaks around all piping connections while the whirlpool is running.
POST INSTALLATION CLEAN-UP
Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor. Do not use wire brushes or any other metal implement on bath surface.
Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or stains may be removed using granular Spic and Span® mixed with water.
Painter’s naphtha can be used to remove excess adhesives and/or wet oil-base paint.
HARSH CHEMICALS SHOULD NEVER BE USED ON ENAMEL SURFACES.
Abrasive cleanars must not be used since they will scratch and dull the surface. Dulled areas can be restored by rubbing with a white automotive-type polishing compound and waxing with a liquid wax.
SPICAND SPAN” IS A REGISTERED TRADEMARK OF THE SPIC AND SPAN COMPANY
In the United States:
American Standard Brands 30 Knightsbridge Road, Suite 301 Piscataway, New
Jersey 08854 Attention: Director of Consumer Affairs
For residents of the United States, warranty information may also be obtained by calling the following toll free number: 800-442-1902 www.americanstandard- us.com
In Canada:
AS Canada ULC 5900 Avebury Ave. Mississauga, Ontario Canada L5R 3M3 Toll Free:
(.800) 387-0369 www.americanstandard.ca
In Mexico:
Customer Service Manager AS Maquila, S.A. de C.V. Via Morelos #330 Col. Santa
Clara Ecatepec 55540 Edo. Mexico
www.amedcanstandard.com.mx
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>